Omron E2E-Y Datasheet

Cylindrical inductive sensor for ac power supply

Advertisement

Cylindrical Inductive Sensor for AC Power Supply
E2E-@Y/E2F-@Y
• 24 to 240 VAC power supply voltage
• brass or plastic housing
(M8 in SUS housing)

Ordering Information

Plastic Housing
AC 2-wire/Pre-wired Models
Size
Sensing
distance
Shielded
M8
1.5 mm
M12
2 mm
M18
5 mm
M30
10 mm
*1. A different frequency type is available (E2F-X@@5; e.g. E2F-X5E15)
*2. A short-circuit protection type is available (E2F-X@Y@-53;
e.g. E2F-X5Y1-53) Power Supply Voltage: 100 to 120 VAC
Metal Housing
AC 2-wire/Pre-wired Models
Size
1.5 mm
M12
2 mm
M18
5 mm
M30
10 mm
Un-
M8
2 mm
shielded
M12
5 mm
M18
10 mm
M30
18 mm
*1. Models with a different frequency are also available. These models are
E2E-X@Y@5 (e.g., E2E-X5Y15).
*2. Cables with a length of 5 m are also available. Specify the cable length at
the end of the model number (e.g., E2E-X2Y1 5M).
E2E-@Y/E2F-@Y
Model
Operating status
NO
NC
*1
E2F-X1R5Y1
E2F-X1R5Y2
*1
*1
E2F-X1Y1
E2F-X2Y2
*1*2
*1*2
E2F-X5Y1
E2F-X5Y2
*1*2
E2F-X10Y1
E2F-X10Y2
Model
mode
NO
NC
E2E-X1R5Y2
NO
*1*2
E2E-X2Y1
NC
NO
*1*2
NC
NO
*1*2
NC
E2E-X10Y2
NO
NC
E2E-X2MY2
NO
*1*2
E2E-X5MY1
NC
NO
*1
NC
E2E-X10MY2
NO
*1
NC
E2E-X18MY2
*1
*1*2
AC 2-wire/Connector Models
Size
Shielded M12
M18
M30
Un-
M12
shielded
M18
M30
Sensing
Operation
distance
mode
2 mm
NO
NC
5 mm
NO
NC
10 mm
NO
NC
E2E-X10Y2-M1
5 mm
NO
E2E-X5MY1-M1
NC
E2E-X5MY2-M1
10 mm
NO
E2E-X10MY1-M1
NC
E2E-X10MY2-M1
18 mm
NO
NC
E2E-X18MY2-M1
Model
1

Advertisement

Table of Contents
loading

Summary of Contents for Omron E2E-Y

  • Page 1: Table Of Contents

    *1. Models with a different frequency are also available. These models are E2E-X@Y@5 (e.g., E2E-X5Y15). *2. Cables with a length of 5 m are also available. Specify the cable length at the end of the model number (e.g., E2E-X2Y1 5M).
  • Page 2: Specifications

    (1) It is not flooded underwater with two atmospheric pressure for 1 hour. (2) A heat shock cycle (it is 1 hour, respectively to 0 °C cold water and 70 °C warm water) is repeated 20 times, and the performance of detection distance and insulation resistance is checked.
  • Page 3: Sensing Operation Distance

    *1. When supplying 24 VAC to any of the above models, make sure that the operating ambient temperature range is over –25 °C. *2. When using an M18- or M30-sized E2E within an ambient temperature of 70 °C to 85 °C, make sure that the E2E has a control output of 5 to 200 mA max.
  • Page 4: Engineering Data

    Pin Arrangement E2E-X@Y@-M1 AC 2-wire Models Operation mode Applicable models Pin arrangement E2E-X@Y1-M1 Load Load Note: Terminals 1 and 2 are not used. E2E-X@Y2-M1 Load Load Note: Terminals 3 and 4 are not used. Cylindrical Inductive Sensor for AC Power Supply...
  • Page 5: E2E-X2My1

    −10 Distance Y (mm) Distance Y (mm) Leakage Current (Typical) E2E-X@Y@ E2F-X@Y@ Protective resistance AC power supply, 50/60 Hz Proximity Sensor (OFF) E2F-XjYj Proximity Protective Sensor resistance (when OFF) AC power supply Supply voltage (V) Power supply voltage (V) E2E-@Y/E2F-@Y...
  • Page 6 Sensing Distance vs. Sensing Object E2F-X1R5@@ E2F-X2@@ Iron Iron E2F-X1R5 Stainless steel SUS304 Brass Aluminum Side length of sensing object d (mm) Side length of sensing object d (mm) E2F-X5@@ E2F-X10@@ Iron Iron Stainless steel SUS304 Stainless steel SUS304 Brass...
  • Page 7: E2E-X10My1 *1

    Sensing Distance vs. Sensing Object (Typical) E2E-X1R5Y@ E2E-X2Y@ E2E-X5Y@ E2F-X1R5Y1@ E2F-X2Y1@ E2F-X5Y1@ t = 1 mm t = 1 mm Iron Iron Stainless steel (SUS304) Iron Stainless steel t = 1 mm (SUS304) Stainless steel (SUS304) Brass Brass Brass Aluminum...
  • Page 8 30 (20) 50 (30) 100 (50) head side (part B) and hence the tightening torque for part B X@Y@ applies. If this nut is in part A, the tightening torque for part A 20 (12) 35 (18) 70 (35) AC 2- applies instead.
  • Page 9: Precautions For Safe Use

    Although the Proximity Sensor has a surge absorption circuit, if there and load respectively, be sure to supply power to the Proximity Sen- is any machine that has a large surge current (e.g., a motor or weld- sor before supplying power to the load.
  • Page 10 Proximity Sensor B, Proximity Sensor B will not operate because the voltage imposed on Proximity Sensor B is 10 V, which is too low. When Proximity Sensor A is OFF, the voltage imposed on Proximity Sensor B will reach the supply voltage and Proximity Sensor B will be ON.
  • Page 11 Note: Vinyl-insulated round cord, 3.5 dia., Oil-and vibration-resistant, 3 cores (0.12 dia. x 13); Standard length: 2 m vinyl-insulated round cord, 6 dia., 0.5 dia. x 2 cores; Standard length: 2 m The cord can be extended up to 200 m in an independent metal conduit.
  • Page 12: E2E-X10Y1-M1

    Toothed Standard length: 2 m Standard length: 2 m washer washer The cable can be exteded up to 200 m The cable can be exteded up to 200 m (separate metal conduit). (separate metal conduit). Fig. 3 : E2E-X2Y@ Fig. 4 : E2E-X5MY@ 21 dia.
  • Page 13 Fig. 9 : E2E-X2Y@-M1 Fig. 10 : E2E-X5MY@-M1 21 dia. 21 dia. M12 × 1 M12 × 1 9 dia. Operating indicator (red) Operation indicator (red) M12 × 1 M12 × 1 Two clamping nuts Two clamping nuts Toothed washer Toothed washer Fig.
  • Page 14: Dimensions And Weights

    OMRON representative at any time to confirm actual specifications of purchased product. Cat. No. D14E-EN-01 In the interest of product improvement, specifications are subject to change without notice. OMRON EUROPE B.V. Wegalaan 67-69, NL-2132 JD, Hoofddorp,...

Table of Contents