Connecting To Screw-Less Clamp Terminal Blocks - Omron CRT1 - 10-2008 Operation Manual

Componet slave units and repeater unit
Table of Contents

Advertisement

Connecting External I/O for Slave Units
Note
3-6-4

Connecting to Screw-less Clamp Terminal Blocks

20-pin Cable
Component
Socket
Semi-cover (See note.)
Hood Cover (See note.)
40-pin Cable
Component
Socket
Semi-cover (See note.)
Hood Cover (See note.)
Note Two Semi-covers are required per connector.
For details on individual components, refer to the Connectors Group Catalog
(Cat. No. G015).
When using a DCN4-MD4 Multidrop Connector to branch a Communications
Cable, bind together the loose wires where the cable comes out of the Hood
Cover. Wire the Communications Cable and loose-wire cable so that they do
not interfere with each other.
For Slave Units with screw-less clamp terminal blocks, the terminal blocks can
be easily wired by inserting pin terminals. Follow the procedure below to con-
nect the external device cable to a screw-less clamp terminal block.
■ Applicable Pin Terminals
When wiring an external device cable to a screw-less clamp terminal block,
special pin terminals must be placed on the cable wires. The applicable pin
terminals are listed in the following table.
Name
Applicable wire size
H0.5/14 orange
0.5 mm
H0.75/14 white
0.75 mm
H1.5/14 red
1.5 mm
The pin terminal conductor should be about 8 to 10 mm in length.
Conductor length: 8 to 10 mm
■ Wiring to the Screw-less Clamp Terminal Block
Inserting Pin Terminals
Insert the pin terminal all the way to the back of the terminal hole.
Insert the pin terminal all the way to the back.
Wire size: AWG24
XG5M-2032-N
XG5S-1001
XG5S-2012
Wire size: AWG24
XG5M-4032-N
XG5S-2001
XG5S-4022
Crimp tool
2
/AWG20
PZ6 roto
2
/AWG18
2
/AWG16
Section 3-6
Wire size:
AWG28 to AWG26
XG5M-2035-N
Wire size:
AWG28 to AWG26
XG5M-4035-N
Manufacturer
Weidmuller Co. Ltd.
97