Connecting To Mil Connector Terminals - Omron CRT1 - 10-2008 Operation Manual

Componet slave units and repeater unit
Table of Contents

Advertisement

Connecting External I/O for Slave Units
Note
3-6-3

Connecting to MIL Connector Terminals

Using OMRON MIL
Cable
Slave model
CRT1-VID16ML
CRT1-VOD16ML
92
Operation lever
(white)
4. Lightly pull the wire to confirm that it is connected properly.
To remove a wire, push in the operation lever, check that the operation lever
has locked, and then pull out the wire. After removing the wire, always return
the operation lever to its normal position.
Use any of the following methods to connect to a MIL connector.
• Use an OMRON MIL Cable.
• Pressure-weld a Flat Cable to a MIL Socket.
• Pressure-weld a loose-wire cable to a MIL connector.
• Connecting Relay Terminals
The MIL Cables for connecting OMRON Relay Terminals are shown in the
following table. Select the appropriate Cable depending on the combina-
tion of Remote I/O Terminals and Relay Terminals that are used.
MIL Cable model
G79-I@C
G79-O@C
Reset opening
Connected Relay
Terminal
G7TC-ID16
G7TC-IA16
G7TC-OC16/OC08
G7OD-SOC16/VSOC16
G7OD-FOM16/VFOM16
G7OA-ZOC16-3
G7OD-SOC08
G7OR-SOC08
Section 3-6
Remarks
---
---