Advertisement

Quick Links

INDEX
Pag.
Contents
2
3
4
5
7
14
22
22
23
All manuals and user guides at all-guides.com
ALPHA SPOT HPE 15
INSTRUCTION MANUAL
Congratulations on choosing a Clay Paky product
We thank you for your custom.
Please note that this product, as all the others in the rich Clay
Paky range, has been designed and made with total quality to
ensure excellent performance and best meet your expectations
and requirements.
Carefully read this instruction manual in its entirety and keep it
safe for future reference. It is essential to know the information
and comply with the instructions given in this manual to ensure
the fitting is installed, used and serviced correctly and safely.
CLAY PAKY S.p.A. disclaims all liability for damage to the fitting
or to other property or persons deriving from installation, use and
maintenance that have not been carried out in conformity with this
instruction manual, which must always accompany the fitting.
CLAY PAKY S.p.A. reserves the right to modify the
characteristics stated in this instruction manual at any time and
without prior notice.
1
1
C61325

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ALPHA SPOT HPE 15 and is the answer not in the manual?

Questions and answers

Summary of Contents for Clay Paky ALPHA SPOT HPE 15

  • Page 1: Table Of Contents

    Control panel the fitting is installed, used and serviced correctly and safely. CLAY PAKY S.p.A. disclaims all liability for damage to the fitting Menu setting or to other property or persons deriving from installation, use and...
  • Page 2: Safety Information

    The products referred to in this manual conform to the European Community Directives to which they are subject: • Low Voltage 2006/95/CE • Electromagnetic Compatibility 2004/108/CE ALPHA SPOT HPE 15...
  • Page 3: Unpacking And Preparation

    (fitted into projector) 099105 2 x 183102/802 Packing contents - Fig. 1 UNLOCKED LOCKED LOCKED UNLOCKED PAN Mechanism Lock and Release every 90°) - Fig. 2 TILT Mechanism Lock and Release every 45°) - Fig. 3 ALPHA SPOT HPE 15...
  • Page 4: Installation And Start-Up

    WARNING: with the exception of when the projector is positioned on the floor, the safety cable must be fitted. (Cod. 105041/003 available on request). This must be securely fixed to the support structure of the projector and then connected to the fixing point at the centre of the base. Connecting and disconnecting power cable - Fig. 5 ALPHA SPOT HPE 15...
  • Page 5: Control Panel

    During menu setting status, after a wait time (about 30 seconds) without any key having been pressed, the display automatically returns to rest status. It should be noted than when this condition occurs, any possible value that has been modified but not yet confirmed with the key will be cancelled. Continue ALPHA SPOT HPE 15...
  • Page 6 All that is needed is to press to momentarily activate the display and thus access the settings. Once the required operations have been carried out, the display will switch off again after a wait time of 30 seconds. ALPHA SPOT HPE 15...
  • Page 7: Menu Setting

    Auto fan speed Display Default Setting Preset User Preset 1 User Preset 2 User Preset 3 Manual Access code Lamp Pan / Tilt Advanced Control 1234 Colour Reset Upload Firmware Beam Channel Setup Model Gobo Calibration Continue ALPHA SPOT HPE 15...
  • Page 8 - the current settings appear on the display (On or Off). 2) Use the UP and DOWN keys to enable (On) or disable (Off) Tilt inversion. 3) Press to confirm the selection or LEFT to keep current settings. ALPHA SPOT HPE 15...
  • Page 9 (1500W) to half-power (1200W) using the LAMP CONTROL channel. Auto fan speed Automatically the fans switch from Full speed to Low speed respectively. 3) Press to confirm the selection or LEFT to keep current setting. Continue ALPHA SPOT HPE 15...
  • Page 10 Partial counter Counts the number of partial projector working life hours since the last reset to date. 2) Press to reset partial projector working hours a confirmation message (Are you sure?) appears on the display. ALPHA SPOT HPE 15...
  • Page 11 Yellow Color W. Strobe Dimmer Dimm.fine Iris Fix Gobo C. Rot. Gobo C. Gobo Rot. Prism C. Prism Rot. L. Frost M. Frost H. Frost Focus Pan Fine Tilt Tilt Fine Function Reset Lamp On/Off Continue ALPHA SPOT HPE 15...
  • Page 12 Test sequence: Pan - Tilt effects (Pan & Tilt) Colour effects (CMY, colour wheel) Beam effects (Stopper-Strobe / Dimmer / Iris / Prism / Frost) Gobo effects (Fixed gobo / Rotating gobo) All effects ALPHA SPOT HPE 15...
  • Page 13 – a confirmation message appears on the display (Reset calibration to factory default ?). 2) Select YES to reset calibration to factory default or NO to keep the current setting and return to the top menu level. ALPHA SPOT HPE 15...
  • Page 14: Maintenance

    1/4 Turn 1/4 Turn Locking and releasing Pan and Tilt movements - Refer to the instructions in the UNPACKING AND PREPARATION section. Opening the head covers - Fig. 11. Closing the head covers - Fig. 12. ALPHA SPOT HPE 15...
  • Page 15 Opening and closing lamp compartment - Fig. 13 Lamp regulation - Fig. 15 To centre the lamp, turn the three adjusting screws as shown in the figure. Lower Side Fan support plate opening and closing Lower side) - Fig. 16 Continue ALPHA SPOT HPE 15...
  • Page 16 Fan support plate opening and closing Upper side) - Fig. 17 Lower Side 085908/001 085907/001 085904/001 085903/001 085912/001 085911/001 085906/001 085901/001 Replacing fixed gobos ø 31.5 mm - max 25 mm image - thickness max 1 mm) - Fig. 18 ALPHA SPOT HPE 15...
  • Page 17 084627/001 Replacing rotating gobos ø 37.4 mm - max 25 mm image – thickness 1 mm) - Fig. 20 IMPORTANT: Use only glass gobos on the rotating gobos wheels. For any further information contact CLAY PAKY. Continue ALPHA SPOT HPE 15...
  • Page 18 • General cleaning of internal parts. • Restoring lubrication of all parts subject to friction, using lubricants specifically supplied by Clay Paky. • General visual check of the internal components, cabling, mechanical parts, etc.
  • Page 19 All manuals and user guides at all-guides.com Extraction of the effect modules: Preliminary operations - Fig. 23 Continue ALPHA SPOT HPE 15...
  • Page 20 Extraction of the effect modules - Fig. 24 IMPORTANT: Grasp the modules using the support structure and not the details which could get damaged. Insertion of the effect modules: Repeat the operations indicated in Fig. 24 and 25 in reverse order ALPHA SPOT HPE 15...
  • Page 21 Extraction of the effect modules - Fig. 25 IMPORTANT: Grasp the modules using the support structure and not the details which could get damaged. Insertion of the effect modules: Repeat the operations indicated in Fig. 24 and 25 in reverse order ALPHA SPOT HPE 15...
  • Page 22: Technical Information

    Signal transmission cable faulty or disconnected. Replace the cables. Incorrect addressing. Check addresses (see instructions). Fault in the electronic circuits. Call an authorised technician. Lenses or reflector broken Call an authorised technician. Dust or grease deposited. Clean (see instructions). ALPHA SPOT HPE 15...
  • Page 23: Channel Functions

    PAN FINE PAN FINE TILT TILT TILT FINE TILT FINE FUNCTION FUNCTION RESET RESET LAMP ON/OFF (with Option Lamp DMX ON) LAMP ON/OFF (with Option Lamp DMX ON) PAN-TILT TIME COLOUR TIME BEAM TIME GOBO TIME Continue ALPHA SPOT HPE 15...
  • Page 24 • COLOUR WHEEL - channel 5 • DIMMER FINE - channel 9 EFFECT EFFECT FAST ROTATION 160 rpm 50.0 SLOW ROTATION 0.2rpm 46.0 BLUE 38.0 ORANGE 30.0 AQUAMARINE 23.0 GREEN 15.0 CTO 3200 WHITE ALPHA SPOT HPE 15...
  • Page 25 12.5 - 15.0 GOBO 4 24 - 31 9.5 - 12.0 GOBO 3 16 - 23 6.2 - 9.0 GOBO 2 8 - 15 3.2 - 6.0 GOBO 1 0 - 7 0 - 3.0 WHITE Continue ALPHA SPOT HPE 15...
  • Page 26 191 - 192 74.7 - 75.0 STOP 74.2 SLOW ROTATION (3 rph) 50.0 50.0 FAST ROTATION (120 rpm) 49.7 POSITION 540° ° 41.7 POSITION 450° 33.0 POSITION 360° ° 24.7 POSITION 270° 16.2 POSITION 180° POSITION 90° ° POSITION 0° ALPHA SPOT HPE 15...
  • Page 27 • AUTOFOCUS ADJUSTMENT - channel 28 EFFECT EFFECT NEAR FOCUS FINE 50.0 DISTANT FOCUS FINE • FOCUS FINE -channel 25 • MACRO EFFECTS - channel 29 EFFECT NEAR DISTANT • ZOOM - channel: 26 EFFECT NARROW BEAM WIDE BEAM ALPHA SPOT HPE 15...
  • Page 28 (Tilt conventionally represented at 14% and option Invert Tilt Off) Operation with option InvertPan Operation with option Invert Tilt (Tilt conventionally represented at 14% and option Invert Tilt Off) (Pan conventionally represented at 0% and option Invert Pan Off) ALPHA SPOT HPE 15...
  • Page 29 Lamp ignition not allowed in half power. 39.5 LAMP ON (1200 W) 39.0 LAMP OFF Lamp switch off passing throug the unused range and staying 5 s in Lamp OFF levels. 10.0 LAMP OFF UNUSED RANGE ALPHA SPOT HPE 15...
  • Page 30 Dimmer - Iris -Focus effects movment - Focus - Zoom - Frost – Rotating Prism change – Frost insertion Gobo time Gobo Fix - Rotating Gobo 1/2 change – Animation Disk insertion TIME TABLE Seconds Seconds Seconds Seconds Seconds Seconds Full 10.2 10.4 10.6 Follow cue Data ALPHA SPOT HPE 15...
  • Page 31 All manuals and user guides at all-guides.com...
  • Page 32 All manuals and user guides at all-guides.com CLAY PAKY - Via Pastrengo, 3/b - 24068 Seriate (BG) Italy - Tel. +39-035-654311 - Fax +39-035-301876 - www.claypaky.it S.p.A.

Table of Contents