Main circuit

Terminal
AC power supply input
R/L1, S/L2, T/L3
Inverter output
U/T1, V/T2, W/T3
Braking resistor connection
B1, B2
DC reactor connection
+2, +1
DC power supply input
+1, –
Grounding

Control Circuit

Signal name
Type
No.
Multi-function input selection 1
S1
Multi-function input selection 2
S2
Multi-function input selection 3
S3
Multi-function input selection 4
S4
Multi-function input selection 5
S5
Multi-function input selection 6
S6
Multi-function input selection 7
S7
Multi-function input selection
SC
Common
Speed reference pulse train input
RP
Power supply terminal for
FS
frequency setting
Speed frequency reference
FR
Frequency reference common
FC
Multi-function analog voltage input
1 (CN2)
Multi-function analog current input
2 (CN2)
Multi-function analog input common
3 (CN2
NO contact output
MA
Contact output
NC
Contact output common
MC
Photocoupler output 1
P1
P2
Photocoupler output 2
Photocoupler output common
PC
AM
Analog monitor output
Analog monitor common
AC
R+
Communication input (+)
Communication input (–)
R–
S+
Communication output (+)
Communication output (–)
S–
Varispeed V7
Name
Main circuit power supply input (use R/L1 and S/L2 for single-phase power supply inverter.
Do not use T/L3 of the models less than 0.75 kW for other usage, such as a junction terminal.)
For inverter output
For braking resistor connection
Remove the short bar between +2 and +1 when connecting DC reactor (option)
For power supply input (+1: positive electrode; – : negative electrode)*
For grounding (grounding should conform to the local grounding code.)
Function
Factory setting: runs when CLOSED, stops when OPEN.
Factory setting: runs when CLOSED, stops when OPEN.
Factory setting: "fault reset"
Factory setting: "external fault (NO contact)"
Factory setting: "multi-step speed reference 1"
Factory setting: "multi-step speed reference 2"
Factory setting: "JOG command"
Common for control signal
33 kHz max.
+12V (allowable current: 20 mA max.)
0 to +10 VDC (20 k ) or 4 to 20 mA (250
0 V
Voltage input (between terminals 1 and 3): 0 to 10 VDC (input impedance: 20 k )
Current input (between terminals 2 and 3): 4 to 20 mA (input impedance: 250 )
Factory setting: "fault"
Factory setting: "running"
Factory setting: "at frequency"
0 V
Factory setting: "output frequency" 0 to +10 V output
(pulse monitor output available by setting constants. Duty: 30 to 70%)
0 V
For MEMOBUS communication
operation by RS-485 or RS-422 communication is available.
Function (signal level)
), 0 to 20 mA (250
) (resolution 1/1000)
Signal level
24VDC, 8mA
photocoupler
insulation
Contact capacity
250 VAC,
1 A or less
30 VDC, 1 A
or less
Photocoupler output:
+48 VDC, 50 mA or
less
0 to 10 V 2 mA
or less
Resolution: 8 bits
RS-485/422
MEMOBUS
protocol
19.2 kBPS max.
341