Hide thumbs Also See for PA L 1-R:

Advertisement

Quick Links

en

Table of contents

1. Intended use .................................................................................................................................................... 1
2. Scope of delivery ............................................................................................................................................ 1
3. Dimensions ...................................................................................................................................................... 2
4. Technical data ................................................................................................................................................. 2
4.1
General .................................................................................................................................................. 2
4.2
Electrical data AC version/DC version .................................................................................................. 3
5. Approvals ......................................................................................................................................................... 3
6. Commissioning ............................................................................................................................................... 4
6.1
Safety information ................................................................................................................................. 4
6.1
Lens cap ................................................................................................................................................ 4
6.2
Electrical connection/control elements PA 1-R / PA L 1-R ................................................................... 6
6.3
Connecting the operating voltage ......................................................................................................... 6
6.4
Setting the operating modes without external control ........................................................................... 6
6.4.1
Setting the tones ............................................................................................................................... 7
6.4.2
Setting the color (only PA L 1-R) ....................................................................................................... 8
6.4.3
Setting the operating mode (only PA L 1-R) ..................................................................................... 8
6.5
Setting the operating modes with external control ................................................................................ 9
6.5.1
Setting the tones ............................................................................................................................... 9
6.5.2
Setting the color (only PA L 1-R) ..................................................................................................... 10
6.5.3
Setting the operating mode (only PA L 1-R) ................................................................................... 10
7. Setting types examples ................................................................................................................................ 11
8. Accessories ................................................................................................................................................... 12
9. Maintenance, service, repairs ...................................................................................................................... 12
10. Decommissioning, dismantling and disposal .......................................................................................... 12
Annex tones table

1. Intended use

Sounders of the PA series are designed for the signaling of e.g. hazardous conditions in industry, trade and
construction areas. There is also the possibility of visual signaling when the sounder-signal lamp combination
(PA L 1-R) is used.
The sounders produce acoustic signals in 70 different tones, which can be selected using an internal switch.
The external control can be used to switch over to a maximum of 3 further tones.
The devices must only be operated when undamaged and within the specified parameters. The function of the
device can only be guaranteed if the upper and lower parts are correctly joined together.
The devices are suitable for indoor and outdoor use.

2. Scope of delivery

The scope of delivery consists of:
1x Signaling device
1x Diaphragm nipple M20 (Optional: Cable gland - M12 plug)
1x Seal for lower cable feed-through
1x Quick guide
03/2024
Operating Manual PA L 1-R / PA 1-R
Page 1 / 12
086200019b

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PA L 1-R and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Pfannenberg PA L 1-R

  • Page 1: Table Of Contents

    5. Approvals ................................. 3 6. Commissioning ............................... 4 Safety information ..........................4 Lens cap ..............................4 Electrical connection/control elements PA 1-R / PA L 1-R ..............6 Connecting the operating voltage ......................6 Setting the operating modes without external control ................6 6.4.1 Setting the tones ..........................
  • Page 2: Dimensions

    Operating Manual PA 1-R / PA L 1-R 3. Dimensions PA 1-R PA L 1-R M20 cutout prepared M20 cutout prepared A suitable fastening material must be used. Bore pattern; view from below 4. Technical data General PA 1-R PA L 1-R...
  • Page 3: Electrical Data Ac Version/Dc Version

    Operating Manual PA 1-R / PA L 1-R Electrical data AC version/DC version PA L 1-R Rated voltage range 24V - 48V AC 115V - 230V AC 12V - 48V DC (see license for limit) 50/60 Hz 50/60 Hz Operation voltage range 10V - 60V DC 18V –...
  • Page 4: Commissioning

    Operating Manual PA 1-R / PA L 1-R 6. Commissioning Safety information DANGER - Danger to life due to electric shock Voltage-carrying units and exposed connection cables may cause electric shocks and serious accidents.  Only trained and authorized electricians may work on electrical connections.
  • Page 5 Operating Manual PA 1-R / PA L 1-R Cable feed-throughs The supplied diaphragm nipple can be replaced by a cable gland or by an M12 plug-in connector with a flange dimension of M20.  Only cable glands with protection category of at least IP66 should be fitted to the corresponding openings.
  • Page 6: Electrical Connection/Control Elements Pa 1-R / Pa L 1-R

    (only C2) Operating voltage connection Connecting the operating voltage Signal lamp and sounder can be supplied together or separately in the PA L 1-R combi-device. Set the DIP switch S2 on the board as follows: Further information in the...
  • Page 7: Setting The Tones

    Operating Manual PA 1-R / PA L 1-R 6.4.1 Setting the tones The tone is set using the S1 switch on the board in the lens, see table below. Without external control S1:6 OFF Tone 162* Factory setting* S1 (DIP1) Volume max.*...
  • Page 8: Setting The Color (Only Pa L 1-R)

    Operating Manual PA 1-R / PA L 1-R 6.4.2 Setting the color (only PA L 1-R) The color is set using the S2 switch on the board in the lens, see table below. S2 (DIP2) Color mode (only RGB) Red*...
  • Page 9: Setting The Operating Modes With External Control

    Operating Manual PA 1-R / PA L 1-R Setting the operating modes with external control 6.5.1 Setting the tones The tone is set using the S1 switch on the board in the lens, see table below. ���� +�������� ���� (not active) C1 ��������...
  • Page 10: Setting The Color (Only Pa L 1-R)

    Operating Manual PA 1-R / PA L 1-R 6.5.2 Setting the color (only PA L 1-R) The color is set using the S2 switch on the board in the lens, see table below. ���� +�������� ���� (not active) �������� Light - colors (only PA L 1-R)
  • Page 11: Setting Types Examples

    Operating Manual PA 1-R / PA L 1-R 7. Setting types examples Green Yellow - Color of lamp � � �� +C2 � � �� (not active) C1 C1+C2 Description Volume Classic Traffic Continuous Continuous light, optional Continuous Tone 2...
  • Page 12: Accessories

    Operating Manual PA 1-R / PA L 1-R 8. Accessories Item No. Designation 28912000001 Spare seal PA (L) 1-R 9. Maintenance, service, repairs  Observe the Safety information during all work on the device. The device requires no special maintenance.

This manual is also suitable for:

Pa 1-r

Table of Contents