Page 1
AQUALOOP DW systems Assembly and operating instructions AL-DW1000 Multi10 (with Multi10 submersible motor pump and drinking water feed into cistern) AL-DW1000 RMF-40SC (with suction pump and integrated drinking water replenishment) WATER, WE’RE IN OUR ELEMENT www.intewa.com...
For installation, operation, maintenance and troubleshooting, the instructions for the components used, which are marked with are required. These can be found in the download area (https://www.intewa.com/de/downloads/) under instructions/data sheets: AQUALOOP-DW systems manual version 1.0a...
Adsorption (activated carbon) to remove dissolved substances and Flavour neutralization Point-of-use (POU) filter (in front of the kitchen tap) Whether one of the additional treatment stages is required must be determined after installation and verification of the water quality achieved. AQUALOOP-DW systems manual version 1.0a www.intewa.de...
3 Safety instructions Before installing the product, you must read these installation and operating instructions carefully. The instructions contained therein must be observed. Modifications to the product are not permitted, as this will invalidate any warranty. Dissolved, organic or inorganic substances (chemicals) in raw water are not removed by ultrafiltration.
4 Guidelines, standards and legal bases Notes: Whenever the AL-DW1000 systems are used, the local, statutory and legal requirements for connection, installation and operation must be observed. These can vary greatly around the world. Due to the lack of legislation and standards, the operator of the system is particularly responsible for operation, maintenance and quality.
Page 7
Table: Notification and approval requirements: Regulatory area Rules and regulations Contents State building As a rule, cisterns of the usual size for detached regulations and semi-detached houses are not considered to be subject to approval. Building permit A description of the proportion of the rainwater system in the property drainage as part of the drainage application is sufficient.
If there is not enough rainwater available, the INTEWA make-up unit ⑥ with a so-called "free outlet" in accordance with DIN EN1717 is used to add drinking water to the cistern as required via a pipe.
Scope of delivery ① ② PURAIN 100 incl. backflow flap Inlet calming DN 100 ③ ④ MULTI-IS 10 submersible motor pump with Horizon pressure hose 10 m floating suction ⑤ ⑥ Wall duct DN 150 Make-up unit with RMD 24 ...
6 System illustration: AL-DW1000 RMF-40 SC The AL-GW1000 RMF-40 SC package includes all components, except tank, pipes and piping, for creating the treatment system. AL-DW1000 RAINMASTER F-40 SC system with RMF-SC 40 pump control unit The so-called "roof run-off water" is first pre-filtered via a PURAIN pre-filter before it enters the ①...
7 Commissioning All components must be commissioned in accordance with the commissioning instructions for the respective component (see ). 8 Maintenance Water quality and monitoring A raw water analysis of the roof run-off water must be carried out before the system is installed.
Further information on maintenance can be found in the corresponding component manuals, which are marked with These can be found on the download page at (https://www.intewa.com/en/downloads/). Table 1 Overview of the maintenance and replacement intervals s Product Control in-...
INTEWA GmbH provides a 24-month warranty for the components from the date of purchase. Please keep the proof of purchase as proof of the warranty period. Within the warranty period, INTEWA GmbH shall, at its discretion, provide warranty by repair or replacement.
Appendix: Checklist for maintenance and replacement intervals Checklist for annual maintenance: Commissioning date: __/__/____ Year of operation: 20_ _ Interval Component Testing/cleaning Date Signature ☐ OK ☐ n. OK checked PURAIN pre-filter ☐ yes ☐ no cleaned ☐ OK ☐ n. OK checked l/min months...
Page 16
☐ OK ☐ n. OK checked PURAIN pre-filter ☐ yes ☐ no cleaned ☐ OK ☐ n. OK checked l/min AL-Direct ☐ Yes ☐ No cleaned* after cleaning: l/min ☐ OK ☐ n. OK Rainmaster Favorit SC checked ☐ OK ☐ n. OK months checked Floating suction...
Need help?
Do you have a question about the AQUALOOP DW and is the answer not in the manual?
Questions and answers