Nidec F600 High IP Step-By-Step Manual

Nidec F600 High IP Step-By-Step Manual

Pump drive
Hide thumbs Also See for F600 High IP:

Advertisement

Quick Links

Diese Anleitung bietet Informationen für eine schnelle Inbetriebnahme eines einfachen Umrichter-Motor-Systems.
This guide provides a fast and simple start-up procedure for a basic drive and motor installation.
Bei aufwendigeren Systemen: Umfassende Betriebsanleitungen, Online-Videos und Hilfsmittel finden Sie unter
For help with more advanced installations: Comprehensive user guides, online videos and help tools can be
unserer Webadresse oder über den vorstehenden QR-Code.
accessed using the web address or QR code above.
EN
DE
Bitte lesen Sie die dem Umrichter beiliegende Sicherheitsdokumentation, bevor Sie den Umrichter montieren oder
Please read the safety information booklet supplied with the drive before installation or set-up.
in Betrieb nehmen.
It is essential to read Section 4.
Beim M300 ist unbedingt der Abschnitt 4.2 in der
to using the Safe Torque Off function in safety systems.
vorstehenden QR-Code hinzuzuziehen, um die Safe Torque Off-Funktion in Sicherheitssystemen zu verwenden.
Pump drive F600 High IP
Step By Step Guide
Frame sizes 3 to 6
www.controltechniques.com/support
15
in the
F600 User Guide
Steuerung – Kurzanleitung
using the web address or QR code above prior
über die Webadresse bzw. den
Part Number: 0478-0646-07
Issue: 7

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the F600 High IP and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Nidec F600 High IP

  • Page 1 Pump drive F600 High IP Step By Step Guide Frame sizes 3 to 6 www.controltechniques.com/support Diese Anleitung bietet Informationen für eine schnelle Inbetriebnahme eines einfachen Umrichter-Motor-Systems. This guide provides a fast and simple start-up procedure for a basic drive and motor installation.
  • Page 2 Only the Safe Torque Off function may be used as a safety component of a machine.. Name and address of the manufacturer and authorised representative Manufacturer: Authorised representative: Nidec Control Techniques Ltd Nidec Netherlands B.V. The Gro Kubus 155...
  • Page 3 Adjustable speed electrical power drive systems - Part 5-2: Safety requirements EN 61800-5-2:2017 - Functional EN 61800-5-1:2007 + A1: Adjustable speed electrical power drive systems - Part 5-1: Safety requirements 2017 + A11: 2021, 4.3, - Electrical, thermal and energy 5.2.3.8, 5.2.6 Safety of Machinery, Safety-related parts of control systems, General principles EN ISO 13849-1:2015...
  • Page 4: Table Of Contents

    Drive Operating modes ..........28 Basic Features .............. 29 Additional Information ............ 31 UL information ............... 36 Drive ratings, cable sizes and fuse ratings ....39 Leroy Somer permanent magnet motor data ....40 F600 High IP Step By Step Guide...
  • Page 5: Introduction

    12. DC bus + 5. Option module slot 2 13. DC bus - 6. Option module slot 3 14. Motor connections 7. Relay connections 15. AC supply connections 8. Control connections 16. Ground connections F600 High IP Step By Step Guide...
  • Page 6: Check The Contents Of The Box

    0 - Supplied separately Configuration: 1 - English 1 - Standard 2 - French U - No Control 3 - Italian M - Master 4 - German F - Follower 5 - Spanish Reserved F600 High IP Step By Step Guide...
  • Page 7: Mount The Drive

    (7.72 in) (12.46 in) (9.76 in) (0.27 in) Figure 3-1 Size 3 High IP Drive and Mounting Hole Dimensions Ø6.00mm Ø6.00mm 73.0mm 255.8mm(10.07in) (0.23in) (0.23in) (2.87in) 22 mm(8.86in) 465.5mm (18.32in) 571.4mm (22.49in) 73.0mm (2.87in) F600 High IP Step By Step Guide...
  • Page 8 221mm(8.70in) (4.17in) Ø7.00mm (0.27in) 470.0mm (18.5in) 571.2mm (22.49in) 106.0mm (4.17in) Figure 3-3 Size 5 High IP Drive and Mounting Hole Dimensions Ø7.00mm 110.0mm (0.27in) 255.8mm(10.07in) 221mm(8.70in) (4.33in) 467.0mm (18.38in) 570.7mm (22.46in) 106.0mm (4.17in) F600 High IP Step By Step Guide...
  • Page 9 Figure 3-4 Size 6 High IP Drive and Mounting Hole Dimensions 316.68mm(12.46in) 248mm(9.76in) 98.0mm Ø7.00mm 98.0mm (0.27in) (3.85in) (3.85in) 478.0mm (18.81in) 573.9mm (22.59in) 98.0mm 98.0mm (3.85in) (3.85in) F600 High IP Step By Step Guide...
  • Page 10: Select Supply / Motor Cables And Fuses

    F600-03200066A 10.4 F600-03200080A 12.6 CC, J or T* F600-03200110A F600-03200127A 12.7 F600-04200180A CC, J or T* F600-04200250A CC, J F600-05200300A or T* CC, J F600-06200500A or T* * These fuses are fast acting. F600 High IP Step By Step Guide...
  • Page 11: Wire The Drive Up

    M6 Nut (10 mm AF) 6.0 Nm 8.0 Nm 6.0 Nm 8.0 Nm 6.0 Nm 8.0 Nm (53.1 lb in) (70.8 lb in) (53.1 lb in) (70.8 lb in (53.1 lb in) (70.8 lb in) F600 High IP Step By Step Guide...
  • Page 12 Power and Ground connections Connect the supply and motor connections using the cables and fuses quoted in the table shown in Step 4. Access to control and power terminals F600 High IP Step By Step Guide...
  • Page 13 Figure 6-1 Size 3 power and ground connections F600 High IP Step By Step Guide...
  • Page 14 Figure 6-2 Size 4 power and ground connections DC Connections Additional ground connection Ground connection studs AC Connections Optional EMC filter Optional line reactor Fuses Motor Optional ground Mains Supply connection supply ground F600 High IP Step By Step Guide...
  • Page 15 Figure 6-3 Size 5 power and ground connections F600 High IP Step By Step Guide...
  • Page 16 Figure 6-4 Size 6 power and ground connections F600 High IP Step By Step Guide...
  • Page 17 > 10 mm² and ≤ 16 mm² The same cross-sectional area as the input phase conductor > 16 mm² and ≤ 35 mm² 16 mm² > 35 mm² Half of the cross-sectional area of the input phase conductor F600 High IP Step By Step Guide...
  • Page 18 Digital I/O (Free to assign) Hand select Auto select Motor protection input Safe Torque Off/ Drive enable Relay 1 Drive Healthy (240 Vac, installation over-voltage category II) Relay 2 Unassigned (240 Vac, installation over-voltage category II) F600 High IP Step By Step Guide...
  • Page 19 KI-485 Adaptor and keypad is wired one to one. The maximum cable length is 100 m when conductors of 0.129 mm² (AWG 26) or larger are used and the cable shield should be connected to the grounded panel / cubicle at the keypad end of the cable. F600 High IP Step By Step Guide...
  • Page 20 When using the Control Techniques converters or any other suitable converter with the drive, it is recommended that no terminating resistors be connected on the network. It may be necessary to disconnect the terminating resistor within the converter depending on which type is used. F600 High IP Step By Step Guide...
  • Page 21: Use The Keypad

    Configured by Status Mode Parameter 2 Pr11.019 The default status display will be automatically shown after 4 minutes if no buttons are pressed, or to show it quickly press the escape button. F600 High IP Step By Step Guide...
  • Page 22: Run The Drive For The First Time In Hand Mode

    T h e r m a l o t e c t i o n o t e c t i o n E n a b l e E n a b l e F600 High IP Step By Step Guide...
  • Page 23 Hand switch. The pump software status changes to Off (Ready). (Ready) 0.00 psi 0.00 psi Reset When safe to do so, check the application for physical items that may be preventing the motor from rotating. F600 High IP Step By Step Guide...
  • Page 24 Set Analogue Input 2 Mode (Pr 07.011) = Therm Short Cct (7). • Set Analogue Input 2 Destination (Pr 07.014) = 0.000 If two analogue inputs are required, then it may be necessary to fit an SI-I/O module. F600 High IP Step By Step Guide...
  • Page 25 If the load is a high inertia, Pr 03.010 may need to be increased. Save parameters. Select 'Save Parameters' in Pr mm.000 and press the red reset button or toggle the reset digital input. F600 High IP Step By Step Guide...
  • Page 26: Running The Drive In Auto Mode

    Stop the motor. Stop the Motor by pressing the red OFF / Reset button or by opening the Hand switch. The pump software status changes to Off (Ready). (Ready) 0.00 psi 0.00 psi Reset F600 High IP Step By Step Guide...
  • Page 27 D e t e c t S p e e d S p e e d T h r e s h o l d T h r e s h o l d 27.00 Hz 27.00 Hz F600 High IP Step By Step Guide...
  • Page 28: Drive Operating Modes

    Position information is required from the feedback device to ensure the output voltage is accurately matched to the back EMF of the motor. Full torque is available down to zero speed. F600 High IP Step By Step Guide...
  • Page 29: Basic Features

    Percentage Load Pr 00.070 when the pump runs dry. Dry well is detected when the load threshold is reached and the drive has reached the maximum reference, as indicated by At Maximum Drive Reference Pr 29.084. F600 High IP Step By Step Guide...
  • Page 30 The last 3 trips are stored in Pr 00.077 to Pr 00.080, with Pr 00.077 being the most recent trip. Refer to the F600 User guide for a complete list of trips and their meaning. F600 High IP Step By Step Guide...
  • Page 31: Additional Information

    Current Only (5) only) 00.015 Low speed (RFC-S 0.0 to sensor-less 05.071 100.0 % mode 1000.0 % mode current only) Symmetrical VM_MOTOR1_CURRENT_LIMIT[MIN] to 00.016 04.007 0.0 % current limit VM_MOTOR1_CURRENT_LIMIT[MAX] % F600 High IP Step By Step Guide...
  • Page 32 0.0 to 6553.5 s 5.0 s low delay PID feedback 00.036 29.043 Disabled (0), Threshold (1), Bandwidth (2) Disabled (0) low mode PID feedback 00.037 29.044 0.00 to 327.67 psi 2.00 psi low threshold F600 High IP Step By Step Guide...
  • Page 33 0.0 to 60.0 0.0 to 3000.0 150.0 detection band No flow 00.057 detection 29.071 0.0 to 6553.5 s 5.0 s delay No flow 00.058 setpoint 29.072 0.0 to 6553.5 s 1.0 s settling delay F600 High IP Step By Step Guide...
  • Page 34 Card No Data (13), Card Full (14), Card File Error (15), Card Rating (16), Card File Data (17), Card Derivative (18) PID final 00.075 29.036 -327.68 to 327.67 psi 0.00 psi feedback 00.076 00.000 F600 High IP Step By Step Guide...
  • Page 35 RFC-A RFC-S RFC-A RFC-S Derivative 00.077 software 29.001 0 to 99999999 version 00.078 Trip 0 10.020 0 to 255 00.079 Trip 1 10.021 0 to 255 00.080 Trip 2 10.022 0 to 255 F600 High IP Step By Step Guide...
  • Page 36: Ul Information

    In this configuration, the unit is mounted sideways with the side panel against the mounting surface. A Tile Mounting Kit is available but must be ordered separately. Terminal Torque Torque settings are specified in relevant sections of this guide. F600 High IP Step By Step Guide...
  • Page 37 Products with DC+ and DC- supply connections have been investigated for use in Modular Drive Systems as inverters when supplied by the converter sections from the Unidrive-M or Mentor MP range. In these applications the inverters are required to be additionally protected by supplemental fuses. F600 High IP Step By Step Guide...
  • Page 38 125 % of full load current of the device ratings Supply from converters These devices are only intended to be supplied by converters manufactured by Control Techniques Ltd. when used as inverters. F600 High IP Step By Step Guide...
  • Page 39: Drive Ratings, Cable Sizes And Fuse Ratings

    @ 575 V @ 575 V Class Class current mm² mm² F600-05500039A CC, J F600-05500061A or T* F600-05500100A F600-06500120A F600-06500170A CC, J F600-06500220A or T* F600-06500270A 18.5 F600-06500340A * These fuses are fast acting. F600 High IP Step By Step Guide...
  • Page 40: Leroy Somer Permanent Magnet Motor Data

    Appendix C Leroy Somer permanent magnet motor data F600 High IP Step By Step Guide...
  • Page 41 F600 High IP Step By Step Guide...
  • Page 42 ħdan il-Gwida għall-Utent fil-URL säkerhetsinformationen i användarhandboken på t’isfel. nedanstående URL-adress. Ostrzeżenie Przed przystąpieniem do użytkowania produktu należy przeczytać ze zrozumieniem informacje dotyczące bezpieczeństwa przedstawione w Podręczniku użytkownika dostępnym pod następującym adresem. www.controltechniques.com/support F600 High IP Step By Step Guide...
  • Page 43 Términos de la garantía Esta oferta está sujeta a nuestros Términos y Condiciones de la Garantía de 5 años, que puede encontrar también en www.controltechniques.com/shield. F600 High IP Step By Step Guide...
  • Page 44 Company information Nidec Control Techniques Limited. Registered Office: The Gro, Newtown, Powys SY16 3BE. Registered in England and Wales. Company Reg. No. 01236886. Moteurs Leroy-Somer SAS. Headquarters: Bd Marcellin Leroy, CS 10015, 16915 Angoulême Cedex 9, France. Share Capital: 65 800 512 €, RCS Angoulême 338567258.

Table of Contents