en Installation and connection
¡ Remove any accessories from the oven.
¡ Lift one side of the appliance off the floor and tilt it
slightly.
¡ Screw the adjustable feet into the mounting holes
on the underside of the appliance.
Note: If you then move the appliance, screw the ad-
justable feet in fully.
¡ Only finally align the appliance once the electricity
and gas have been connected and all of the installa-
tion work is complete.
4.2 Gas connection
Only an authorised expert or a licensed customer ser-
vice technician may install the appliance in accordance
with the instructions specified under "Gas connection
and conversion to a different gas type".
¡ The settings for configuring your appliance can be
found on the rating plate on the rear of the appli-
ance. The gas type set at the factory is marked with
an asterisk (*).
¡ Find out about the local supply conditions regarding
the gas type and gas pressure before installing the
appliance, and ensure that the gas setting for the
appliance complies with this information.
¡ Connect and install this appliance in accordance
with the applicable to the installation instructions.
¡ Do not connect this appliance to a waste gas main
on the combustion products. Do not connect this
appliance to an exhaust gas outlet. Comply with all
ventilation regulations.
¡ Establish the gas supply using a permanent, non-
elastic connection, such as a gas pipe or a flexible
safety gas hose.
¡ If a flexible safety gas hose is used, ensure that the
hose is not jammed or squeezed. Keep the hose
away from hot surfaces.
¡ On some appliances, you can connect the gas pipe
to the gas pipe or flexible safety gas hose on the
right-hand or the left-hand side of the appliance. If
necessary, you can change the connection side.
The connection must have a free-standing and eas-
ily accessible locking device.
Target appliance operating pressure
¡ You can find the target operating pressure for your
appliance on the rating plate on the rear of the ap-
pliance.
¡ All the data on your appliance's rating plate relates
to these pressure values.
8
¡ The manufacturer is not responsible for results, per-
formance or any risk caused by operating the appli-
ance at different values.
WARNING ‒ Risk of explosion!
Escaping gas may cause an explosion. If the gas pres-
sure in your distributing pipes is more than 20% higher
than the values specified on the appliance's rating
plate, a gas leak can occur.
For your own safety, it is imperative that you operate
▶
the appliance with a suitable gas governor.
If you do not know what the gas pressure in your
▶
gas distributing pipes is, please ask your local gas
company.
Connection, maintenance and setting of the gas
▶
governor must be carried out by an authorised in-
stallation specialist.
A gas leak could occur. If you move the appliance after
the gas supply has been established, a gas leak could
occur.
Do not move the appliance once the gas supply is
▶
connected.
If you move the appliance, check that the connec-
▶
tions are not leaking.
For the licensed expert or after-sales service
The settings for configuring your appliance can be
1.
found on the rating plate.
Find out which gas type and which gas pressure
2.
your local gas supply network uses before installing
the appliance, and ensure that the gas setting for
the appliance complies with this information. If the
appliance settings have to be changed, follow the
instructions in the section "Gas connection and con-
version to a different gas type".
This appliance is not connected to a waste gas
3.
main. It must be positioned and connected in ac-
cordance with the applicable installation conditions.
Do not connect the appliance to a waste gas main.
Ensure that suitable ventilation measures are carried
out.
Establish the gas supply using a permanent, non-
4.
elastic connection, such as a gas pipe or a safety
hose.
If you use a safety hose, ensure that the hose is not
5.
trapped or compressed. The hose must not come
into contact with hot surfaces.
The connection must have an easily accessible
6.
locking device.
Flexible hoses
Do not pinch or squeeze hoses.
1.
Do not subject the hoses to twisting or pulling
2.
forces.
Keep the hoses away from sharp edges.
3.
Do not let the hoses come into contact with parts
4.
that may reach a temperature higher than 70 °C
above room temperature.
Ensure that the full length of the hoses can be ac-
5.
cessed for testing.
Checking for leaks
After connecting the gas pipe, use soapy water to
▶
check the connections for leaks.
Need help?