National Instruments PCI-6551 Getting Started Manual

National Instruments PCI-6551 Getting Started Manual

Digital waveform generator/analyzer
Hide thumbs Also See for PCI-6551:

Advertisement

Quick Links

GETTING STARTED GUIDE
NI Digital Waveform
Generator/Analyzer
For NI PXI/PCI-6551/6552 Devices
This document explains how to install, configure, test, and set up a National
Instruments digital waveform generator/analyzer. This document applies
specifically to the NI PXI-6551/6552 (NI PXI-655X) and the
NI PCI-6551/6552 (NI PCI-655X), collectively called the NI 655X. For more
information on the NI 655X, such as features and programming, refer to the
NI Digital Waveform Generator/Analyzer Help at Start»Programs»
National Instruments»NI-HSDIO»Documentation»NI Digital
Waveform Generator/Analyzer Help.
Refer to the specifications document that ships with your device for detailed
specifications.
For free downloads of the most current versions of product documentation
and example programs, visit
Contents
Conventions ...............................................................................................2
1. Verifying the System Components ........................................................4
Minimum System Requirements .......................................................4
Recommended System.......................................................................4
2. Unpacking ..............................................................................................5
3. Verifying the Kit Contents.....................................................................6
Documentation...................................................................................6
4. Installing the Software ...........................................................................6
Choose and Install Your ADE ...........................................................6
Install NI-HSDIO...............................................................................7
NI Script Editor..........................................................................7
January 2004
323308B-01
ni.com/instruments
.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PCI-6551 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for National Instruments PCI-6551

  • Page 1: Table Of Contents

    Instruments digital waveform generator/analyzer. This document applies specifically to the NI PXI-6551/6552 (NI PXI-655X) and the NI PCI-6551/6552 (NI PCI-655X), collectively called the NI 655X. For more information on the NI 655X, such as features and programming, refer to the NI Digital Waveform Generator/Analyzer Help at Start»Programs»...
  • Page 2: Conventions

    5. Installing the Hardware................8 Installing a PXI Module..............8 Installing a PXI Module in a CompactPCI Chassis ....9 Maintaining PXI Systems ............10 Uninstalling PXI Modules ............10 Installing a PCI Device ..............11 Maintaining PCI Systems ............12 6. Configuring and Testing in MAX............12 Using the Test Panel to Generate and Acquire Data ......13 7.
  • Page 3 Italic text in this font denotes text that is a monospace italic placeholder for a word or value that you must supply. NI 655X Refers to the NI PXI-6551/6552 and NI PXI-6551/6552. © National Instruments Corporation NI Digital Waveform Generator/Analyzer Guide...
  • Page 4: Verifying The System Components

    Peripheral Component Interconnect (PCI) is a high-performance expansion bus architecture originally developed by Intel to replace ISA and EISA. PCI eXtensions for Instrumentation (PXI) is a rugged, open system for modular instrumentation based on CompactPCI, with special mechanical, electrical, and software features. These features, such as the PXI trigger bus, are described in the PXI Specification Revision 2.0, which is available from ni.com/manuals...
  • Page 5: Unpacking

    One of the following digital waveform generator/analyzer accessories: – NI CB-2162 single-ended digital I/O accessory – NI SMB-2163 breakout box accessory • National Instruments SMB cables, available in various styles from ni.com • Windows 2000/NT 4.0 SP6A/XP/Me/98 SE • One of the following application development environments (ADEs): –...
  • Page 6: Verifying The Kit Contents

    Remove the device from the package and inspect it for loose components or any other signs of damage. Notify NI if the device appears damaged in any way. Do not install a damaged device in your computer or chassis. Store the device in the antistatic package when the device is not in use. 3.
  • Page 7: Install Ni-Hsdio

    The NI DWE allows you to easily import data from popular third-party EDA programs, create your own waveforms, edit these waveforms, and view acquired waveforms. If you are using the NI DWE, install it after you install NI-HSDIO. © National Instruments Corporation NI Digital Waveform Generator/Analyzer Guide...
  • Page 8: Installing The Hardware

    5. Installing the Hardware To install your NI digital waveform generator/analyzer, follow the instructions in the section that describes your hardware platform. When installing your hardware, follow the instructions in this section to ensure that your device can cool itself effectively. If the device temperature rises above the optimal operating temperature range, the device disables itself, and MAX or NI-HSDIO notifies you with an error message.
  • Page 9: Installing A Pxi Module In A Compactpci Chassis

    NI PXI modules is not guaranteed between CompactPCI devices with different sub-buses nor between CompactPCI devices with sub-buses from different vendors and PXI. The standard implementation for CompactPCI does not include these sub-buses. © National Instruments Corporation NI Digital Waveform Generator/Analyzer Guide...
  • Page 10: Maintaining Pxi Systems

    • The module works in any standard CompactPCI chassis adhering to the PICMG CompactPCI 2.0 R2.1 document. • When you use the NI 655X as a plug-in device in a standard CompactPCI chassis, you cannot access PXI-specific functions. PXI-specific features are implemented on the J2 connector of the CompactPCI bus.
  • Page 11: Installing A Pci Device

    6. Before operating the device, install all filler panels. Missing filler panels disrupt the necessary air circulation in the PC. 7. Replace the PC cover. 8. Plug in and power on the PC. © National Instruments Corporation NI Digital Waveform Generator/Analyzer Guide...
  • Page 12: Maintaining Pci Systems

    Personal Computer PCI Device PCI Slot Figure 2. PCI Installation Maintaining PCI Systems Inspect the onboard fan on a regular basis to prevent fan and air circulation path blockage. Cleaning frequency depends on the amount of use and the operating environment. 6.
  • Page 13: Using The Test Panel To Generate And Acquire Data

    1. Right-click the device under NI-DAQmx Devices, and select Test Panels as shown in Figure 3. 2. Click the Generation tab. © National Instruments Corporation NI Digital Waveform Generator/Analyzer Guide...
  • Page 14 3. Select the Dynamic tab on the side of the pane. 4. Click Select All to select all of your channels. The digital pattern now appears in the graph. 5. Enter the frequency in the Clock Frequency control, located on the left side of the test panel.
  • Page 15: Connecting Signals

    For more information about using the NI CB-2162, refer to the NI CB-2162 User Guide. NI also offers the NI SMB-2163 breakout box for National Instruments single-ended digital waveform generator/analyzers. The NI SMB-2163 offers coaxial SMB connectors for each signal on the DDC connector, providing an easy way to connect to other devices for testing and debugging.
  • Page 16 NI PXI-1042 NI PXI-6551 50 MHz Digital I/O ACCESS ACTIVE PFI 0 1 PXI Chassis with NI Digital Waveform 2 SHC68-C68-D2 Cable Generator/Analyzer 3 NI CB-2162 Accessory Figure 4. Connecting the NI CB-2162 Accessory NI PXI-1042 NI PXI-6551 50 MHz Digital I/O ACCESS ACTIVE PFI 0...
  • Page 17: Wiring For Common Measurements

    50 Ω as possible to minimize signal reflections and maintain optimal signal quality. Figure 7 shows a diagram of an example dynamic acquisition system. Use © National Instruments Corporation NI Digital Waveform Generator/Analyzer Guide...
  • Page 18: Programming The Digital Waveform Generator/Analyzer

    NI-HSDIO to set the NI 655X input impedance to 10 kΩ or 50 Ω depending on your application. Refer to the NI Digital Waveform Generator/Analyzer Help for more information about signal termination. Peripheral Device Cable NI 655 X NI CB-2162 Figure 7.
  • Page 19: Appendix A: Device Front Panels

    PFI 2 DIO 1 DIO 0 DDC CLK OUT STROBE The Digital Data & Control connector pinout is the same for PXI and PCI devices. Figure 8. NI 655X Front Panel Connectors © National Instruments Corporation NI Digital Waveform Generator/Analyzer Guide...
  • Page 20 Table 1. NI 655X SMB Connectors Signal Signal Connector Name Type Description CLK IN Reference/ Control Terminal for the external Reference Clock Input clock used for the PLL or for the external Sample clock used for pattern generation and/or acquisition. PFI 0 Programmable Control...
  • Page 21: Appendix B: Troubleshooting

    4. Reinstall the NI PXI-655X using the procedure described in step 5. Installing the Hardware. 5. Power on your PXI chassis. 6. Verify the device appears in MAX. © National Instruments Corporation NI Digital Waveform Generator/Analyzer Guide...
  • Page 22: Device Does Not Appear In Max

    7. Reset the device in MAX and perform a self-test. Refer to 6. Configuring and Testing in MAX for information on performing device resets and self-tests in MAX. 8. If the ACCESS LED still fails to light, contact NI support at ni.com/support Device Does Not Appear in MAX Complete the following steps if the NI 655X does not appear in MAX:...
  • Page 23: Technical Support Resources

    Technical Support Resources NI Web Support National Instruments Web support is your first stop for help in solving installation, configuration, and application problems and questions. Online problem-solving and diagnostic resources include frequently asked questions, knowledge bases, product-specific troubleshooting wizards, manuals, drivers, software updates, and more. Web support is available through the Technical Support section of ni.com.
  • Page 24 Taiwan 886 2 2528 7227, Thailand 662 992 7519, United Kingdom 44 0 1635 523545 CVI™, LabVIEW™, National Instruments™, NI™, ni.com™, and NI-DAQ™ are trademarks of National Instruments Corporation. Product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National Instruments products, refer to the appropriate location: Help»Patents in your software, the patents.txt file on your CD, or...

This manual is also suitable for:

Pci-6552Pxi-6551Pxi-6552

Table of Contents