Advertisement

Quick Links

Installation
guide
Panorama-Kamin
depths 25/40/42
©2020

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FIREPLACE PANORAMA 51/25/101/25 and is the answer not in the manual?

Questions and answers

Summary of Contents for Brunner FIREPLACE PANORAMA 51/25/101/25

  • Page 1 Installation guide Panorama-Kamin depths 25/40/42 ©2020...
  • Page 2: Table Of Contents

    Fireplaces equipped with a water boiler must be pressure-tested after hydraulic connection to the heating system. Masonry work may follow only after this pressure test. Ulrich Brunner GmbH does not cover any costs incurred by necessary dismantling of masonry for rework at water boiler installation or replacement of the boiler.
  • Page 3: Product Description

    Please keep these instructions. PRODUCT DESCRIPTION Fireplaces manufactured by Ulrich Brunner GmbH are designed and approved as self-closing devices ac- cording to EN 13229. Combustion air is supplied through a provided connecting piece. The volume of supplied combustion air can be controlled by using a combustion air controller.
  • Page 4: Equipotential Bonding And Lightning Protection

    If additional parts are installed on the fireplace which are not approved for this appliance by Ulrich Brunner GmbH (for example, an external control unit), it is a customized product that meets cus- tomer requirements. The resulting fireplace insert is not type-tested; the declaration of performance of this fireplace insert will be no longer valid.
  • Page 5: Delivery Contents

    Where sufficient volume of combustion air is not guaranteed. Where flammable materials or explosives are stored, manufactured or processed. Which are commonly accessible. Stairways in residential buildings with access from only two flats are not considered as commonly accessible rooms. © 2020 Brunner GmbH (1.27)
  • Page 6 - If the construction type or dimensioning of the systems are excluding the possibility of dangerous negative pressure. Please consult the location of your fireplace, chimney connection and combustion air supply with your local chimney sweep. (1.27) © 2020 Brunner GmbH...
  • Page 7: Combustion Air

    For buildings with more than two storeys and when crossing fire protection walls, the construction of these ducts must prevent fire and smoke from penetrating other fire protection zones (their components must have a fire resistance rating of >90 minutes (F90)). See also national building law. © 2020 Brunner GmbH (1.27)
  • Page 8: Chimney And Smoke Pipe Connection

    The damper flap must have openings around it, that are not less than 3% of the cross-sectional area, but at least 20 cm wide. (1.27) © 2020 Brunner GmbH...
  • Page 9: Installation

    To do this, unscrew the screws in front and at the sides (posi- tions X). Illustration 1: Detaching the upper side of the mounting frame Illustration 2: Align the bottom side Illustration 3: Control the upper side Illustration 4: Support © 2020 Brunner GmbH (1.27)
  • Page 10 Install the fireclay lining of the combustion chamber as described in the enclosed manual. Cladding of fireplace Do not wall in the door frame. An expansion joint must be pro- vided between frame and cladding material. (1.27) © 2020 Brunner GmbH...
  • Page 11: Overview Of Fire Safety And Protection Of Other Structures Against Heat

    Installation in front of or next to an adjacent wall Installation in front of or next to a flammable wall (U val- (U value ≥0.4W/m²K): ue ≤0.4W/m²K): Illustration 7: Basic principles of fire safety and heat insulation © 2020 Brunner GmbH (1.27)
  • Page 12 Air cooled heat protection Distance between floor insulation and air intake Decorative beam over fireplace door Thermal insulation of the smoke pipe connecting piece Heat radiation range Fireplace Reheating surface Heating gas pipe Convection casing Convection air duct (1.27) © 2020 Brunner GmbH...
  • Page 13: Connections And Assembly

    Appropriate external casing materials -> see TROL. Building surfaces can form parts of the external casing (mounting surfaces = e.g. floor area, ceiling area; ad- jacent wall = part of building wall which is in direct contact with the fireplace casing). © 2020 Brunner GmbH (1.27)
  • Page 14 Its construction must be self-supporting. Between the stove/fireplace insert and the external casing, as well as between the supporting frame and the casing, an expansion strap and/or sealing tape must be used to compensate the different expansions caused by high temperature. (1.27) © 2020 Brunner GmbH...
  • Page 15: Building Protection

    Technical Data for flammable materials or other materials including flammable components are valid only for components with a heat transfer coefficient (U value) ≥ 0,4W/m²K. For U value < 0,4W/m²K, additional mea- sures for thermal insulation must be taken (see DIN 18896:2013-12). © 2020 Brunner GmbH (1.27)
  • Page 16 (37), only outside the heat ra- diation range. The clearance must not allow for heat accumulation be- tween the beam and the fireplace wall. Decorative beams cannot be parts of the building structure. (1.27) © 2020 Brunner GmbH...
  • Page 17 Electric lines Mounting surface must be free from typical electrical wiring, unless it is protected by special measures against permanent influence of temperatures >30°C (86°F). Special wiring with higher heat resistance is per- mitted (see TROL). © 2020 Brunner GmbH (1.27)
  • Page 18: Approved Insulation Materials

    Shells, Limit 2 Shells Slabs, Limit 1 Segments Slabs, Limit 2 Braids Panels *) 99 is valid only for delivery forms in column 2, which have no declared limits. **) 99 is valid only for shells. (1.27) © 2020 Brunner GmbH...
  • Page 19 Dimension sheets - Panorama-Kamin 42/42/42/42 lifting door (easy-lift) … with firetable frame wide Stand: 2020-11-19...
  • Page 20 Dimension sheets - Panorama-Kamin 42/42/42/42 lifting door (easy-lift) … with firetable frame narrow We suggest for CAD planning Palette CAD. Permanent updated drawings: www.brunner.de Frames /flue gas outlet connection/ combustion air supply connection/ front variants are marked in color. Stand: 2020-11-19...
  • Page 21 Planning and installation - Panorama-Kamin 42/42/42/42 lifting door (easy-lift) Tested according to EN 13229 W Values measured at Rated capacity Suitable for all construction types according to rules Data for functional demonstration Rated heat power Fire wood volume kg/h Combustion performance Flue gas mass flow Flue gas temperature after: metalic hot air hood...
  • Page 22 Dimension sheets - Panorama-Kamin 57/40/60/40 lifting door (easy-lift) … with firetable frame wide Stand: 2020-11-19...
  • Page 23 Dimension sheets - Panorama-Kamin 57/40/60/40 lifting door (easy-lift) … with firetable frame narrow We suggest for CAD planning Palette CAD. Permanent updated drawings: www.brunner.de Frames /flue gas outlet connection/ combustion air supply connection/ front variants are marked in color. Stand: 2020-11-19...
  • Page 24 Planning and installation - Panorama-Kamin 57/40/60/40 lifting door (easy-lift) Tested according to EN 13229 W Values measured at Rated capacity Suitable for all construction types according to rules Data for functional demonstration Rated heat power Fire wood volume kg/h Combustion performance Flue gas mass flow Flue gas temperature after: metalic hot air hood...
  • Page 25 Dimension sheets - Panorama-Kamin 57/40/85/40 lifting door (easy-lift) … with firetable frame wide Stand: 2020-11-19...
  • Page 26 Dimension sheets - Panorama-Kamin 57/40/85/40 lifting door (easy-lift) … with firetable frame narrow We suggest for CAD planning Palette CAD. Permanent updated drawings: www.brunner.de Frames /flue gas outlet connection/ combustion air supply connection/ front variants are marked in color. Stand: 2020-11-19...
  • Page 27 Planning and installation - Panorama-Kamin 57/40/85/40 lifting door (easy-lift) Tested according to EN 13229 W Values measured at Rated capacity Suitable for all construction types according to rules Data for functional demonstration Rated heat power 13.5 Fire wood volume kg/h Combustion performance Flue gas mass flow Flue gas temperature after:...
  • Page 28 Dimension sheets - Panorama-Kamin 57/25/60/25 lifting door (easy-lift) … with firetable frame wide Stand: 2020-11-19...
  • Page 29 Dimension sheets - Panorama-Kamin 57/25/60/25 lifting door (easy-lift) … with firetable frame narrow We suggest for CAD planning Palette CAD. Permanent updated drawings: www.brunner.de Frames /flue gas outlet connection/ combustion air supply connection/ front variants are marked in color. Stand: 2020-11-19...
  • Page 30 Planning and installation - Panorama-Kamin 57/25/60/25 lifting door (easy-lift) Tested according to EN 13229 W Values measured at Rated capacity Suitable for all construction types according to rules Data for functional demonstration Rated heat power Fire wood volume kg/h Combustion performance Flue gas mass flow Flue gas temperature after: metalic hot air hood...
  • Page 31 Dimension sheets - Panorama-Kamin 57/25/85/25 lifting door (easy-lift) … with firetable frame wide Stand: 2020-11-19...
  • Page 32 Dimension sheets - Panorama-Kamin 57/25/85/25 lifting door (easy-lift) … with firetable frame narrow We suggest for CAD planning Palette CAD. Permanent updated drawings: www.brunner.de Frames /flue gas outlet connection/ combustion air supply connection/ front variants are marked in color. Stand: 2020-11-19...
  • Page 33 Planning and installation - Panorama-Kamin 57/25/85/25 lifting door (easy-lift) Tested according to EN 13229 W Values measured at Rated capacity Suitable for all construction types according to rules Data for functional demonstration Rated heat power 13.5 Fire wood volume kg/h Combustion performance Flue gas mass flow Flue gas temperature after:...
  • Page 34 Dimension sheets - Panorama-Kamin 51/25/101/25 lifting door (easy-lift) … with firetable frame wide Stand: 2020-11-19...
  • Page 35 Dimension sheets - Panorama-Kamin 51/25/101/25 lifting door (easy-lift) … with firetable frame narrow We suggest for CAD planning Palette CAD. Permanent updated drawings: www.brunner.de Frames /flue gas outlet connection/ combustion air supply connection/ front variants are marked in color. Stand: 2020-11-19...
  • Page 36 Planning and installation - Panorama-Kamin 51/25/101/25 lifting door (easy-lift) Tested according to EN 13229 W Values measured at Rated capacity Suitable for all construction types according to rules Data for functional demonstration Rated heat power Fire wood volume kg/h Combustion performance 14.5 Flue gas mass flow Flue gas temperature after:...
  • Page 37 Dimension sheets - Panorama-Kamin 57/25/121/25 … with firetable frame wide Stand: 2020-11-19...
  • Page 38 Dimension sheets - Panorama-Kamin 57/25/121/25 … with firetable frame narrow We suggest for CAD planning Palette CAD. Permanent updated drawings: www.brunner.de Frames /flue gas outlet connection/ combustion air supply connection/ front variants are marked in color. Stand: 2020-11-19...
  • Page 39 Planning and installation - Panorama-Kamin 57/25/121/25 Tested according to EN 13229 W Values measured at Rated capacity Suitable for all construction types according to rules Data for functional demonstration Rated heat power Fire wood volume kg/h Combustion performance Flue gas mass flow Flue gas temperature after: metalic hot air hood °C...
  • Page 40 Dimension sheets - Panorama-Kamin 70/25/40/25 lifting door (easy-lift) … with firetable frame wide Stand: 2020-11-19...
  • Page 41 Dimension sheets - Panorama-Kamin 70/25/40/25 lifting door (easy-lift) … with firetable frame narrow We suggest for CAD planning Palette CAD. Permanent updated drawings: www.brunner.de Frames /flue gas outlet connection/ combustion air supply connection/ front variants are marked in color. Stand: 2020-11-19...
  • Page 42 Planning and installation - Panorama-Kamin 70/25/40/25 lifting door (easy-lift) Tested according to EN 13229 W Values measured at Rated capacity Suitable for all construction types according to rules Data for functional demonstration Rated heat power Fire wood volume kg/h Combustion performance Flue gas mass flow Flue gas temperature after: metalic hot air hood...
  • Page 43 Energy efficiency class: Direct heat output: 11,0 kW Indirect heat output: N.A. kW Energy efficiency index: Fuel energy efficiency (at nominal heat output): 82,0 % Fuel energy efficiency (at minimum load): N.A. % Special precautions: © 2020 Brunner GmbH (1.27)
  • Page 44 Energy efficiency class: Direct heat output: 8,0 kW Indirect heat output: N.A. kW Energy efficiency index: Fuel energy efficiency (at nominal heat output): 82,0 % Fuel energy efficiency (at minimum load): N.A. % Special precautions: (1.27) © 2020 Brunner GmbH...
  • Page 45 Technical and assortment changes as well as errors and Zellhuber Ring 17-18 misprints reserved. D-84307 Eggenfelden Reprinting and reproduction, even in part, only with Tel.: +49 (0) 8721/771-0 / Fax: +49 (0) 8721/771-100 the express permission of the publisher. Email: info@brunner.de Art.Nr.: 200001 © 2020 Brunner GmbH (1.27)

Table of Contents