Inverter Compressor - Fujitsu AMUG30LMAS Service Manual

Hide thumbs Also See for AMUG30LMAS:
Table of Contents

Advertisement

4-2. Inverter compressor

Check point 1. Check the terminal connection.
Check the following terminal connections of the compressor. (Loosening or incorrect wiring.)
Check terminal connection of inverter PCB (loose or incorrect wiring)
Check point 2. Check the winding resistance.
Check the winding resistance of each terminal.
Resistance value
30 model: 0.676 Ω ± 8 % at 68 °F (20 °C)
36/48 model: 0.240 Ω at 68 °F (20 °C)
T(W)
→ If the resistance value is 0 Ω or infinite, replace the compressor.
4-2. Inverter compressor
S(V)
(WHITE)
Main PCB
R(U)
(RED)
Inverter PCB
P400(U) P401(V)
RED
Compressor
RED
R(U)
WHITE
S(V)
BLACK
- (03-51) -
T(W)
(BLACK)
P402(W)
BLACK
WHITE
4. Service parts information