Customer Guidance - Fujitsu ASYG 18 KLCA Installation Manual

Table of Contents

Advertisement

STEP 2
Setting the Function Number and Setting Value
1
Press the SET TEMP. (
)
(
) buttons to select the function number.
(Press the MODE button to switch between the
left and right digits.)
2
Press the FAN button to proceed to setting the
value.
(Press the FAN button again to return to the
function number selection.)
3
Press the SET TEMP. (
)
(
) buttons to select the setting value.
(Press the MODE button to switch between the
left and right digits.)
4
Press the SLEEP button, then after you hear
the beep emitted from the indoor unit, press the
START/STOP button to confi rm the settings.
5
Press the RESET button to cancel the function setting mode.
6
After completing the FUNCTION SETTING, be sure to disconnect the power and
reconnect it again.
After disconnecting the power, wait 10 seconds or more before reconnecting it again.
The Function Setting does not become active unless the power is disconnected then
reconnected again.
12.1. Function Details
Filter sign
Select appropriate intervals for displaying the fi lter sign on the indoor unit according to the
estimated amount of dust in the air of the room.
If the indication is not required, select "No indication" (03).
Function
Setting Value
Number
00
01
11
02
03
Room temperature control for indoor unit sensor
Depending on the installed environment, correction of the room temperature sensor may
be required.
Select the appropriate control setting according to the installed environment.
The temperature correction values show the difference from the "Standard setting" (00)
(manufacturer's recommended value).
Setting
Function Number
Value
00
01
02
03
04
05
06
07
08
30
31
(For cooling)
(For heating)
09
10
11
12
13
14
15
16
17
Function
number
Setting
value
CAUTION
(♦... Factory setting)
Setting Description
Standard (400 hours)
Long interval (1,000 hours)
Short interval (200 hours)
No indication
(♦... Factory setting)
Setting Description
Standard setting
No correction 0.0 °C
-0.5 °C
-1.0 °C
-1.5 °C
-2.0 °C
cooling
-2.5 °C
heating
-3.0 °C
-3.5 °C
-4.0 °C
+0.5 °C
+1.0 °C
+1.5 °C
+2.0 °C
cooling
+2.5 °C
heating
+3.0 °C
+3.5 °C
+4.0 °C
Auto restart
Enable or disable automatic restart after a power interruption.
Function
Setting Value
Number
40
* Auto restart is an emergency function such as for power outage etc. Do not attempt to
*1
use this function in normal operation. Be sure to operate the unit by remote controller or
external device.
Remote controller custom code
(Only for wireless remote controller)
The indoor unit custom code can be changed. Select the appropriate custom code.
Function
*1
Setting Value
Number
44
Indoor unit fan control for energy saving for cooling
Enables or disables the power-saving function by controlling the indoor unit fan rotation when
the outdoor unit is stopped during cooling operation.
Function
Setting Value
Number
49
00: When the outdoor unit is stopped, the indoor unit fan operates continuously following
the setting on the remote controller.
01: When the outdoor unit is stopped, the indoor unit fan operates intermittently at a very
low speed.
Setting record
Record any changes to the settings in the following table.
Setting Description
Filter sign
Room temperature control for indoor
unit sensor
Auto restart
Remote controller custom code
Indoor unit fan control for energy saving for
cooling
After completing the FUNCTION SETTING, be sure to disconnect the power and reconnect it
again.

13. CUSTOMER GUIDANCE

Explain the following to the customer in accordance with the operation manual:
(1) Starting and stopping method, operation switching, temperature adjustment, timer, airfl ow
switching, and other remote control unit operations.
(2) Air fi lter removal and cleaning, and how to use the air louvers.
More
(3) Give the operation manual to the customer.
Less
Less
More
(♦... Factory setting)
Setting Description
00
Enable
01
Disable
(♦... Factory setting)
Setting Description
00
A
01
B
02
C
03
D
(♦... Factory setting)
Setting Description
00
Disable
01
Enable
Setting Value
Cooling
Heating
En-9