Instructions for the installer

8. INSTALLATION

8.1 Safety instructions for installing in kitchen units

Veneers, adhesives or plastic coatings on adjacent furniture should be temperature-resistant (>90°C). If
they are not sufficiently temperature-resistant, they may warp over time.
The minimum distance between a ventilation hood and the cooking surface must be at least the distance
indicated in the ventilation hood installation instructions.
The minimum distances must also be respected for the edges of the hob on the back as indicated in the
assembly illustrations.

8.2 Section cut from the work surface

The following operation requires building and/or carpentry work so must be carried out by a competent
tradesman.
Installation can be carried out on various materials such as masonry, metal, solid wood or plastic
laminated wood as long as they are heat resistant (T 90°C).
Create an opening with the dimensions shown in the figure in the top surface of the counter, keeping a
minimum distance A from the rear edge.
This appliance can be mounted against walls higher than the work surface on condition that a minimum
distance B be kept between the appliance and the wall as shown in the figure so as to avoid damage
from overheating.
Make sure there is a minimum distance C between the hob and any shelf that may be installed directly
above it.
X (mm)
Y (mm)
Z (mm)
A (mm)
B (mm)
C (mm)
600
560
500
50 min.
50 min.
750 min.
35