Page 1
Operator's manual Please read carefully before using the machine! Keep for future use This operator's and assembly manual is an integral part of the machine. Suppliers of new and second-hand machines are required to document in writing that the operator's and assembly manual was delivered with the machine and handed over to the customer.
4 Performing a spreading test Conduction of a spreading test with one pass Conduction of a spreading test with two passes Conduction of a spreading test with three passes 5 Evaluating the results and correcting them if necessary PPS 5 AXIS H 5903597...
Scope of delivery and assembly of practical test kit Scope of delivery Measuring tape, 1 piece Hopper, 5 pieces Plastic vessel, 10 pieces Locking bolt, 5 pieces Plastic insert, 10 pieces Tube, 5 pieces Foot rest, 5 pieces PPS 5 AXIS H 5903597...
Page 6
1. AXIS H field test kit Assembling the measuring tubes Fig. 1: Assembling measuring tubes Insert locking bolt [3] into foot rest [4]. Fit tube [2] on to locking bolt. Insert hopper [1] into tube [4]. 5903597 PPS 5 AXIS H...
Perform a turning test (see operating manual of your fertilizer spreader). • Adjust metering valves on the left and right (see operating manual for your fertilizer spreader). • Note down the start settings in chapter 4 Performing a spreading test. PPS 5 AXIS H 5903597...
Due to this characteristic, this spreading pattern is less susceptible to influences such as: • Side wind, • Humidity, • Changed fertilizers and quality. These triangular spreading patterns are usually achieved with fertilizers with very good flight properties (such as calcium ammonium nitrate). 5903597 PPS 5 AXIS H...
Page 9
Changed fertilizers and quality. These trapezoidal spreading patterns result from fertilizers with very good flying properties and large working widths (e.g. 36 m), from fertilizers with less good flying properties (e.g. light or angular fertilizers) PPS 5 AXIS H 5903597...
Performing a spreading test with the desired travel speed and metering quantity for the application: • Open the metering valves 10 m upstream of the collecting vessels. • Close the metering valves 30 m downstream of the collecting vessels. • Spread on both sides. 5903597 PPS 5 AXIS H...
Page 11
When a layer of fertilizer develops in the spreading vane, the spreading characteristics and transverse distribution may change. Carry out the inspection only after approx. 300 kg of urea has been spread per disc and a possible layer has developed. PPS 5 AXIS H 5903597...
When a layer of fertilizer develops in the spreading vane, the spreading characteristics and transverse distribution may change. Carry out the inspection only after approx. 300 kg of urea have been spread per disc and a possible layer has developed. 5903597 PPS 5 AXIS H...
When a layer of fertilizer develops in the spreading vane, the spreading characteristics and transverse distribution may change. Carry out the inspection only after approx. 300 kg of urea has been spread per disc and a possible layer has developed. PPS 5 AXIS H 5903597...
Measure, test With spreading result [A], even distribution Settings are OK (permissible deviation ± 1 graduation mark) Note that a deviation of ± 1 graduation mark corresponds to the measurement deviation and is not a problem. 5903597 PPS 5 AXIS H...
Page 15
Examples for the correction of the spreader setting: Fertilizer distribution Measure, test With spreading result [B], too much fertilizer in the Select setting of feed point sooner (e.g. feed point overlap zone. adjustment from 5 to 4). PPS 5 AXIS H 5903597...
Page 16
Examples for the correction of the spreader setting: Fertilizer distribution Measure, test With spreading result [C], too little fertilizer in the Select setting of feed point later (e.g. feed point overlap zone. adjustment from 4 to 5). 5903597 PPS 5 AXIS H...
Page 17
If the deviations are relatively small, a speed reduction only without feed point adjustment may also be sufficient. Always test step-by-step: First feed point, then the speed. PPS 5 AXIS H 5903597...
Page 18
However, only take these measures in the event of over-fertilization of two graduation marks. Otherwise, please apply the measures from test result C. In case of any queries or problems, our test hall is available for you at testhalle@rauch.de and +49 (0) 7221 985-254.