Page 6
8.5.3 Stimulus Magnitude in Time Domain ..............169 8.5.4 Port Impedance ....................169 8.5.5 Velocity Factor & Dielectric Constant ..............169 8.5.6 Power Level......................169 8.5.7 Average ....................... 170 8.5.8 IF Bandwidth ....................... 170 8.5.9 Trigger Mode ....................... 170 www.siglent.com...
Page 7
Overview ......................189 8.10.2 Usage Guidelines ....................190 Guide for the SA Option ....................192 Overview ....................... 192 User Interface ....................... 192 Create a Spectrum Analysis Channel ..............193 Spectrum Analyzer Settings ................. 194 9.4.1 SA Tab Setting ..................... 194 www.siglent.com...
Page 8
Screenshot setting ....................238 13.1.5 Screensaver ......................238 13.1.6 System language ....................238 13.1.7 Power ........................239 13.2 Input and Output Setting ..................239 13.2.1 Network Setting ....................239 13.2.2 BIAS ........................240 13.2.3 GPIB ........................241 13.2.4 External Device ....................241 www.siglent.com...
Page 9
Key and touch screen test ................... 245 13.7 Options ......................... 245 13.8 External Ports ....................... 245 14 Service and Support ......................246 14.1 Ordering and activating the options ..............246 14.2 Warranty overview ....................247 14.3 Contact Us ......................247 www.siglent.com...
⚫ SIGLENT products are protected by patent law in and outside of P.R.C. ⚫ SIGLENT reserves the right to modify or change parts of or all the specifications or pricing policies at company’s sole decision. ⚫ Information in this publication replaces all previously corresponding material.
"Waste Disposal/Environmental Protection" chapter. In the event of a fire, this product may release harmful substances (gas, liquids, etc.), causing health problems. Therefore, appropriate measures must be taken, for example, protective masks and protective clothing must be worn. www.siglent.com...
If the installation is not carried out in accordance with the requirements of the document, it may cause personal injury or even death. Do not use this product in or near a heat source, and the ambient temperature cannot exceed the www.siglent.com...
This product must be used in a dry environment, otherwise it may cause electric shock. It is forbidden to use this product when condensation has formed or may form inside or on the surface of this product. For example, when the network analyzer moves from a cold environment to a warm www.siglent.com...
For long-distance transportation under unsupervised, please take out the battery and put it in your handbag. In order to facilitate the user to hold, SIGLENT Technology has installed a fabric handle on the network analyzer. This handle cannot be used as a focus point to be fixed on transportation equipment, such as cranes, forklifts, trucks, etc.
Improper battery replacement may cause an explosion. For the reliability and safety of the network analyzer, the battery model specified by SIGLENT Technology must be replaced. Used batteries and battery packs must be recycled and separated from residual waste. Batteries contain hazardous waste, and local regulations on waste disposal and recycling must be followed.
⚫ CAT Ⅰ: 0- An instrument with no rated measurement category is used to measure circuits that are not directly connected to the mains, such as a circuit board powered by a battery or a secondary www.siglent.com...
Page 17
Used for measurements installed in buildings, such as junction boxes, circuit breakers, distribution boards and equipment that are permanently connected to fixed installations. ⚫ CAT IV: It is used for measuring at the source of low-voltage devices, such as electricity meters and primary overcurrent protection devices. www.siglent.com...
This product is powered by mains conforming to installation (overvoltage) category II. WARNING Make sure that no overvoltage (such as that caused by thunderbolt) can reach the product, or else the operator might expose to danger of electric shock. www.siglent.com...
Page 19
Please make sure that the air intake and exhaust areas are free from obstructions and have free air. When using the network analyzer in a bench-top or rack setting, provide at least 10 cm clearance beside, above and behind the instrument for adequate ventilation. www.siglent.com...
To make the network analyzer completely power off, unplug the instrument power cord from the AC socket and remove the battery from the analyzer. The battery should be removed from the analyzer when it is not to be used for an extended period of time. www.siglent.com...
If the packing case or foam protective pad is seriously damaged, keep it until the whole machine and accessories pass the electrical and mechanical tests. Inspection machine If you notice external damage, contact your SIGLENT dealer or local office, and SIGLENT will arrange for a repair or replacement. Check the accessories Please check the accessories according to the packing list in the box.
To deploy the tilt bracket, pull the bottom of the tilt bracket away from the back of the instrument. To retract the tilting bracket, push the bottom of the bracket toward the back of the instrument. Figure 4-2 Side View www.siglent.com...
◆ Battery factory installed, the user can change itself WARNING This instrument can only use Siglent approved batteries, adapters and chargers. When using an onboard DC adapter, always ensure that the power supply is rated at least 75 W @ 15 VDC and that there is no dust or debris on the socket.
Built-in fan external exhaust port. Please ensure that this Fan vent vent is unblocked. Internal battery protection cover. Remove during battery Battery case cover replacement. Detachable Convenient hand force, can be installed on both sides. hand strap www.siglent.com...
Page 25
◆ Under default reset, the operation interface is in menu selection mode, and function keys will be identified as the blue silk screen function identifier on the upper side of the key. Use Enter to switch from menu selection mode to value input mode. www.siglent.com...
Page 26
In the menu selection mode, view help information, version information, etc. In menu selection mode, perform system general information viewing, version and calibration operations, as well as input and output port settings, screen display settings, etc.ell as input and output port Settings, screen display Settings, etc. www.siglent.com...
The main USB port is TypeC. The analyzer can be used as a slave device and connected to a PC via USB cable. The PC uses the USB- Device TMC protocol to remotely control the analyzer. USB slave port, TypeB. The analyzer can be used as the main www.siglent.com...
Page 28
RF signal should not exceed +20 dBm. WARNING Before connecting any signal, short connect the inner core of the test cable to the housing floor to release the static electricity accumulated on the inner core of the test cable. www.siglent.com...
Display the basic configuration and information of the currently selected trace, as well as hardware status and notifications. Notifications Menu area Used to configure measurement Settings. Battery and Display battery level and remote control status. Remote status Active entry 4.5.1 Functions Functions Description Recall the previous step. www.siglent.com...
Windows, keeping the trace to the maximum or minimum value without displaying the current value, etc. Select a trace line and press the Scale button to change the reference electric equalization ⚫ operation. www.siglent.com...
The parameters are shown in SWR. Label Page 4.5.7 Displays all parameter display formats supported by the vector network analyzer. Window State 4.5.8 ⚫ Windows can be used to view trace data and up to 100 windows can be created. www.siglent.com...
Displays the current date information and error information during testing. 4.5.12 Graffiti Function This product provides a basic graffiti function, which is used to draw graphics and mark information on the main interface. This feature is great for annotating screenshots and adding important details before saving. www.siglent.com...
Page 33
SHN900A User Manual ⚫ Graffiti function menu bar Figure 4-5 graffiti function menu bar As shown in Figure 4-5, the graffiti menu contains functions of enable, edit, clear, save and call. ⚫ Graffiti Editing Interface www.siglent.com...
Page 34
10. Background filling tool: Fill graphics background color (support graphics: text, rectangle, ellipse) 11. Border color tool: Set the border color of graphics (support graphics: text, line, rectangle, ellipse, curve) 12. Border line tool: Adjust the border line thickness of graphics (support graphics: text, line segment, rectangle, ellipse, curve) www.siglent.com...
Page 35
As shown in Figure 4–7, after calling out this interface, you can adjust the corresponding colors of the graphics: Color shade selection tool: Mouse/ finger click to select the appropriate brightness of the color Color selection tool: Select a specific color Color transparency tool: Adjust color transparency (the more right, the lower color transparency) www.siglent.com...
Click the save menu button to save the current graffiti content as a file with *.GFT as the file extension. 4.5.13 Theme Management In the "Theme Management" panel, Siglent provides display configuration options for the measurement panel, allowing you to flexibly configure parameters such as trace color thickness, XY axis font style, and view grid style.
Page 37
Press the “Display” button on the front panel → “Display Setup” →“Theme Manager…” to enter the "Theme Management" panel. Siglent supports importing and saving themes. Select a specific theme from the theme drop-down menu to configure the measurement panel display parameters in one step.
Page 38
4.5.13.1.4 Response Axis "Window" → "Response Axis" to enter the response axis style setting menu, where you can set the font size, font style, and font weight of the response axis. www.siglent.com...
Page 39
Siglent supports importing and exporting color configuration files. Click on "Import" on the bottom right side and select the corresponding file to complete the color configuration in one step; Click on "Export", select the save path and set the file name to save your current color configuration.
◆ The waveform is scaled horizontally at two points in the measurement result area to change the X-axis display range ◆ Click the shortcut menu area, working status area, scanning parameter area and menu area for function selection ◆ Click editable parameters, virtual numeric keyboard or QWERT keyboard will pop up, parameter www.siglent.com...
The analyzer supports communication with computers via USB, LAN, and GPIB-USB interfaces. By using these interfaces, in combination with programming languages and/or NI-VISA software, users can remotely control the analyzer based on a SCPI (Standard Commands for Programmable Instruments) compliant command set, LabView and IVI (Interchangeable Virtual Instrument), to www.siglent.com...
◆ If the fan and screen are normally powered on, but the screen stops in the startup screen, or the button does not respond If the above problems exist, do not disassemble the instrument and contact SIGLENT in time. The analyzer enters the working state normally, and the buttons and touch screen should respond to the measurement operation normally.
Page 43
If the above problems exist, do not disassemble the instrument and contact SIGLENT in time. The analyzer should be in scanning or measuring state when working normally, and the screen waveform and parameters are in updating state.
SHN900A User Manual Set Up a Measurement This chapter introduces in detail each function button on the front panel of SHN900A series vector network analyzers and the following menu functions. Measurement parameters S parameters 5.1.1 S parameters are used to describe the degree of a transmitted or reflected signal through an impedance discontinuity.
On balanced devices, the signal of interest is the difference and average of the two input or output lines. In balanced device terminology, these signals are known as the Differential and Common modes. ● Signal A is fixed at 1V peak ● Signal B is selectable ● Differential is calculated as A minus B www.siglent.com...
Page 46
S21 is a ratio measurement of the device Output/device Input. Mixing this with balanced terminology, we could view the amplifier's Differential Output signal/ Differential Input signal. To see this parameter on the analyzer, we would select an Sdd21 measurement using the following balanced notation: www.siglent.com...
Page 47
In the balanced measurement, the signal of interest is the difference or average of two BALANCED input or BALANCED output lines. It is also possible to have single-ended ports AND balanced ports on the same device. Press the “Meas” button on the front panel → Balanced → Topology... , Create or edit DUT Topology www.siglent.com...
1 Logical port (Balance Port 1) - 2 physical ports (Port1, Port2) Wave 5.1.4 Receivers can be also selected using logical receiver notation Press the “Meas” button on the front panel → Wave → Other... to enter the Wave TAB interface. www.siglent.com...
Page 49
When logical port 1 is mapped to physical port 1, it is equivalent to A,1; b2,1 Represents Physical port 1 outputs power when the test port receiver of logical port 2 is measured. When logical port 2 is mapped to physical port 2, it is equivalent to B,1; www.siglent.com...
"b2/a1,1" means that the logical source port number is 1, and the logical port ratio 2 measurement receiver/logical port 1 reference receiver. Frequency range Frequency range is the span of frequencies you specify for making a device measurement. www.siglent.com...
Press Freq use the knob or arrow keys to focus on the Freq → CW parameter entry. Select the edit box to enter the edit mode and change the value by pressing the up and down key, rotating the knob, or pressing the numeric keypad. Press ENTER, the knob, or ESC to exit editing mode. www.siglent.com...
Press Sweep, use the knob or arrow keys to focus on the Sweep → Number of Points parameter item, Enter the number of points required, Press ENTER to exit editing mode. The number of data points collected by the vector network analyzer during the measurement sweep can be set to any number between 2 and 20001. www.siglent.com...
Knob to select the current option. Sweep type: ● Linear Frequency ● Log Frequency ● Power Sweep ● CW Time ● Segment Sweep Linear Frequency: Set the measured abscissa frequency scale as a linear scale, and keep the full www.siglent.com...
Page 54
Knob, set the sweep type as Segment Sweep, and press ENTER or Knob to select the current option. Press Sweep, use the knob or arrow keys to focus on the Segment Table parameter item. Move www.siglent.com...
Page 55
When X-axis point spacing is used, the X-axis position of each point needs to be selected so that all measurement points are evenly distributed along the X-axis. For example, suppose you have the following two sections: Figure 5-2 X-point spacing is not used www.siglent.com...
Trigger source: These Settings determine the source of the trigger signal for all existing channels. A valid trigger is generated only if the vector network analyzer is not sweeping. ● Internal triggers: After the previous measurement is completed, the vector network analyzer will immediately send a continuous trigger signal. www.siglent.com...
At this point, however, all channels are set to single trigger. ● Continuous trigger: Channels accept an unlimited number of trigger signals. ● Hold all channels: All channels enter the hold state and do not accept any trigger signals. www.siglent.com...
If full 2-port calibration is on, triggering 1 will cause no trace to be updated. When the calibration is off, triggering 1 will cause S11 and S21 updates. Trigger 2 will cause updates to S22 and S12. Trace sweep order: www.siglent.com...
The external device sends a trigger signal to the vector network analyzer when it is ready for measurement ● Additional signals are provided on the vector network analyzer processor I/O to indicate that the vector network analyzer sweep has been completed and the processor can be set for the next measurement. www.siglent.com...
Page 60
All other signals will be ignored. ● If this check box is cleared, any trigger signals received by the vector network analyzer before it is ready will be ignored. ● This feature is only available when a positive or negative edge trigger is selected. www.siglent.com...
Page 61
Channels: All secondary trigger settings will be applied to the specified channel and each channel can be configured individually. Auxiliary channel output (to device): The following settings control the properties of the signal emitted from the “Auxiliary Trigger Output ” www.siglent.com...
ENTER or the knob to select the current option. Cartesian coordinates display format 5.6.2 Nine of the twelve available data formats use rectangular displays to present measurement data. This www.siglent.com...
Page 63
180 degrees, then the phase measurement may not be accurate. Group delay format: ● Displays the transmission (propagation) time of signal in the device ● Y: Time (s) ● Typical measurement: Group delay www.siglent.com...
Only imaginary parts of the measured data are displayed ● Y: No units ● Typical measurement: Network impedance matching Polar coordinates 5.6.3 The polar coordinate format is used to view the amplitude and phase of the reflection coefficients in S11 or S22 measurements. www.siglent.com...
In the Smith chart, the linear impedance plane is reshaped to form a cyclic grid from which the resistance and reactance (R+ Jx) can be read. You can use a cursor to display the following items: ● Resistance (in Ohms) ● Reactance as equivalent capacitance (in Ephraeras) or inductance (in Henrys) www.siglent.com...
Page 66
Each point on the Smith chart represents a complex impedance (r±jx) consisting of a real resistance (r) and an imaginary reactance (x). ● The horizontal axis (solid line) shows the real part of the difference between impedance and resistance. The horizontal axis always represents the system impedance. The rightmost www.siglent.com...
The vector network analyzer determines the minimum possible scaling factor that will allow all display data to appear on the 80% vertical grid. The selected reference values center the trace on the screen. All autoscaling: Automatically scales all data traces in the working window to fit vertically into the www.siglent.com...
If traces of a different format exist, all traces of that format will be set as the least numbered trace in that format ● Once enabled, the scale settings for all coupling traces of the same format can be changed with any coupling trace in the working state www.siglent.com...
Knob. Press ENTER or Knob to select the current option. Delay time: Specifies the value of the delay added or removed, expressed in time or distance. This compensates for the linear phase shift through the device. Electrical delay can be set separately for each measuring trace. www.siglent.com...
Simulate Projection phase shift in measurements. For example, if you know that you need to add a cable and that the length of the cable will add a certain phase shift to the measurement, you can use a phase shift to increase the length and simulate the entire device measurement. www.siglent.com...
Knob. Press ENTER or Knob to select the current option. Note: The logarithmic scale type can only be selected when the display format is linear magnitude scheme, real number format or imaginary number format. Other formats are linear scale type. www.siglent.com...
Averaging is a feature that the VNA averaging on each data point before stepping to the next data point. You determine the number of measurements by setting the averaging factor. The higher the averaging factor, the greater the amount of noise reduction. Averaging setting: Press the “Avg BW” key, then enter the Averaging and Bandwidth menu. www.siglent.com...
Each tenfold reduction in IF bandwidth lowers the noise floor by 10 dB. However, narrower IF bandwidths cause longer sweep times. IF Bandwidth setting: Using the Softkey for setting: Press the “Avg BW” key, Press “Avg BW” > Averaging > IF Bandwidth > Enter the IF Bandwidth value. www.siglent.com...
Trace Smoothing reduces the peak-to-peak noise values on broadband measured data. It smooths trace noise and does not increase measurement time significantly. Smoothing setting: Using the Softkey for setting: Press the “Avg BW” key, “Avg BW” > Smoothing then enter the Smoothing menu. www.siglent.com...
Preset types are available through Preset → Preset Option, Select “Default”, “Last”, or “User”. ● Press the Preset key, and the device invokes either default Settings or user Settings. Table 5-1 Some default setting values Parameter name Parameter value RF Power RF state RF level -10 dBm www.siglent.com...
Page 76
Log Mag Scale Scale 10 dB Reference level 0 dB reference position Scale coupling Delay time Delay distance Distance unit meter Speed coefficient System impedance 50 Ω Phase deviation 0° Amplitude deviation 0 dB Average Average state Smooth state Calibration www.siglent.com...
Page 77
SHN900A User Manual Calibration state unloaded calibration data www.siglent.com...
DUT and move the measurement plane to the DUT. Then, Port match, N-port embedding/ de-embedding, port impedance conversion are used to embed or de-embed expected virtual networks. If balance scattering parameters are measured, balance conversion, differential port match, differential port impedance conversion, common port www.siglent.com...
Page 80
Required calibration kits: short circuit, open circuit, load, through) or ECAL electronic calibration parts module ● Directivity ● Source match ● Isolation ● Load match ● Frequency response ● Frequency response transmission tracking reflection tracking Enhanced Response: Application: Calibrate two ports when only one direction (forward or reverse) is needed for www.siglent.com...
Page 81
One port (reflection): Application: Used to accurately calibrate any test port suitable for reflection measurement only Overall accuracy: High Required calibration kits: Short circuit, open circuit, and load or ECAL module Corrected system error: ● Directivity ● Frequency response reflection tracking www.siglent.com...
User can check the execution status of error correction for each channel with the error correction status. The error correction status is indicated in the channel status bar in the lower part of the window by the symbols in the below table. www.siglent.com...
Page 83
"CΔ" appears in the status bar when one or more of the following stimulus settings change. The resulting measurement accuracy depends on which parameter has changed and how much it has changed. For optimum accuracy, recalibrate using the new settings. Sweep time IF Bandwidth www.siglent.com...
The calibration property displays the acquisition status of the calibration coefficient between test ports for each channel in matrix format. The following figure shows an example of when the calibration coefficients have been acquired for the full 2-port calibration between test ports 1 and 2. www.siglent.com...
Method 1: Click the channel error correction execution status symbol in the channel status bar to open and close, as shown in the left figure below. Method 2: Press "Cal” on the front panel > Cal > Correction, as shown in the right figure below. www.siglent.com...
Improving the accuracy of the models for predefined kits. When the model describes the actual performance of the standard, the calibration is more accurate. For example, A 7 mm LOAD is determined to be 50.4 Ω instead of 50.0 Ω. ● Modifying the THRU definition when performing a calibration for a non-insertable device. www.siglent.com...
Page 87
C. Save the existing Cal kits and change the file name. D. Create a new custom Cal Kit. E. Select the Cal Kit. Save the current Cal kits (both factory and custom). G. Recall the Cal Kits. H. Restore the default factory Cal kits. www.siglent.com...
Page 88
D. Frequency Range: Define the lowest and the highest frequency at which the standard is used for calibration. E. Gender: Gendered or Genderless Impedance: Specify the impedance of the standard. G. Transmission Media: The medium of the connector, COAX or WAVEGUIDE www.siglent.com...
Page 89
Standards dialog box help, the following fields apply to ALL standard types. Figure 6-5 The help dialog of the Standard A. Identification Standard ID: Number in list of standards Label: Type of standard. This usually appears in prompts for standards. Description: Description of standard. www.siglent.com...
Page 90
Loss: Defines energy loss in Gohms, due to skin effect, along a one-way length of coaxial cable. Open Standard C0, C1, C2, C3: Specify the fringing capacitance. Figure 6-6 Open Characteristics Short Standard L0, L1, L2, L3: Specify the residual inductance. Figure 6-7 Short Characteristics Load Standard Figure 6-8 load Characteristics www.siglent.com...
Page 91
Figure 6-10 DATA-BASED Characteristics 6.4.1.4 SOLT Tab Allows you to assign single or multiple standards to SOLT Calibration Classes. For each Cal Kit Class, select Available Standards from the left list, then click >> to copy the standard to the Cal Kit www.siglent.com...
Page 92
Allows you to assign single or multiple standards to Calibration Classes. For each Cal Kit Class, select Available Standards from the left list, then click >> to copy the standard to the Cal kit. Use Move Up and Move Down to change the ORDER of the standards. www.siglent.com...
Page 93
The THRU standard and LINE standard have the same characteristic impedance and are perfectly matched. They define the reference impedance of the calibration. ● If a THRU standard with the correct connectors is NOT available, an adapter removal Cal can be performed. B. TRL REFLECT www.siglent.com...
Page 94
For best results, use the same load on both ports. The load may be defined using the data-based definition, the arbitrary impedance definition, or the fixed load definition. E. Calibration Reference Z0 ● System Z0: The system impedance is used as the reference impedance. Choose when the www.siglent.com...
Page 95
Method 1: Create custom Cal Kit based on existing Cal kits Press “Cal” > Cal > Cal Kit > F503ME > Save. Select the existing F503ME Cal Kit then save it to a local file named “F503ME123.xkt”. Figure 6-13 Creating a Custom Cal Kit dialog box www.siglent.com...
Page 96
In the Manage Cal Kits dialog box, click “Import” to Import the new calibration “F503ME123.xkt”. Figure 6-15 Import the new ECal Kit Select the newly imported calibration, click “Edit” to enter the calibration editing interface, and modify the calibration name as “F530ME-ABC”. www.siglent.com...
Page 97
Figure 6-16 Edit the new import ECal Kit Click the Connectors, Standards, SOLT, and TRL Tabs to modify the corresponding parameters as you need. Click “OK” for the changed Cal Kit to take effect. Figure 6-17 View the newly created Cal Kit www.siglent.com...
Cal Kit pull-down option. Select the gender properties of the calibration connector from the DUT Connector drop-down option, and select the corresponding calibration method from the Cal Type drop-down option, as shown in the figure below: www.siglent.com...
Page 99
Save State menu bar. Select State+Cal Data from the Save Type drop-down option, click Save State As and enter the file name, and click OK to Save the current calibration Data and the current setting State. www.siglent.com...
OPEN calibration element to the test port. If the LOAD calibration element is used for isolation calibration at the same time, the directional error can be calculated. Figure 6-22 Schematic diagram Operating steps: www.siglent.com...
Short for calibration, and click Finish to exit the calibration interface, complete the calibration, and save the calibration data. Full 1 port OSL calibration 6.4.5 All 1-port OSL calibration connects the OPEN, SHORT, and LOAD calibration elements to the test www.siglent.com...
Two-port transmission response calibration is to connect the THRU calibration kit between two ports to calculate the transmission tracking error in the test device error model. If the LOAD calibration kit is used for isolation calibration at the same time, isolation error (crosstalk error) can also be calculated. www.siglent.com...
Select Cal → Basic Cal to enter the setting interface. Select both Port 1 and Port 2, select the desired calibration kit in the Cal Kit, select the type of calibration connector, Female or Male, in the DUT Connector, Select Enhanced Response 1 www.siglent.com...
Select both Port 1 and Port 2, select the desired calibration kit in the Cal Kit, select the type of calibration connector, Female or Male, in the DUT Connector, select SOLT in the Cal Type, and click Next to proceed to the next step. www.siglent.com...
Connect the THRU calibration kit between the two ports according to the interface prompts. The parameters of the THRU do not have to be known. Carry out unknown through Thru calibration. After the calibration, click Finish to exit the calibration interface, complete the calibration, and www.siglent.com...
Taking the two-port SOLT calibration as an example, the following describes the partial overwrite calibration for achieving full two-port open calibration after completing full two-port SOLT calibration. www.siglent.com...
The vector network analyzer has been calibrated for the output power of the transmitter before it leaves the factory, but the factory calibration may not guarantee sufficient accuracy in all cases. To improve the accuracy, the user can conduct an internal source power calibration before performing any tests. www.siglent.com...
Page 108
Before attempting power calibration, power loss compensation at different frequency points can be set as shown in the figure below. Click “+” successively to add corresponding frequency and loss values. After setting, click OK to save the data. Figure 6-27 Set the interface www.siglent.com...
The user can conduct a receiver power calibration before the test to improve the test accuracy. To ensure the calibration accuracy of the receiver, it is better to calibrate the power of the internal source before the calibration of the receiver. www.siglent.com...
After the S parameter calibration is performed, the reference plane can be extended to the specified measurement plane by simply adding the added microstrip line length, speed factor, loss, and other parameters in the setting interface, to carry out more accurate testing. www.siglent.com...
Page 111
Loss(f) = Loss1 * (f/Freq1) ^ n, n = lg [abs(Loss1/Loss2)] / lg (Freq1/Freq2). Select whether to coupling to the system speed factor. If unchecked, the speed factor is set only for the specified port, and when checked, for all ports. www.siglent.com...
Page 112
Select the port you want to extend. Refer to practical application scenarios, select Port 1 or Port 2, or both ports. Select the frequency span of the test. There are three frequency spans to choose: Current Span: The frequency span of the current interface setting. www.siglent.com...
Fixture measurement function In addition to the port extension function, the vector network analyzer also provides several other functions for test fixtures: Port match (2-port embedding) Port impedance conversion 2-port de-embedding N port embed/ de-embed (port 4/6/8) Differential port match www.siglent.com...
Page 114
S2P file making the frequency range of the S2P file the same as the frequency range of the current interface. Click Close to complete the setting and click Apply Fixtures to ON to take effect. www.siglent.com...
Page 115
S parameter corresponding to the new characteristic impedance. Checking the Enable Port Z Conversion On All Ports tab means port matching is performed on all ports. Click Close to complete the setting and click Apply Fixtures to ON to take effect. www.siglent.com...
Page 116
Checking the Reverse Adapter Ports entry represents the part of the reverse connection that will need to be de-embedding. By default, the system reverses the imported S2P file. Click Close to complete the setting and click Apply Fixtures to ON to take effect. www.siglent.com...
Page 117
In other words, all the uncovered low-frequency parameters are replaced by the first point in the S2P file, and all the uncovered high-frequency parameters are replaced by the last point in the S2P file, making the frequency range of the S2P file the same as the frequency range of the www.siglent.com...
Page 118
S2P file and all the uncovered high-frequency parameters are replaced by the last point in the S2P file making the frequency range of the S2P file the same as the frequency range of the current interface. Click Close to complete the setting and click Apply Fixtures to ON to take effect. www.siglent.com...
Adapters are often used when the network analyzer is used to test the DUT. The vector network analyzer provides the function of removing and inserting adapters. Before the function of removing and inserting adapters is enabled, the vector network analyzer needs to carry out full 2-port calibration. www.siglent.com...
Page 120
Click Next to connect the Open, Short and Load calibration elements in turn for full 1 port calibration. Click Finish to complete the calibration and click Adapter Removal to ON to complete the Adapter Removal operation. www.siglent.com...
ECal offers the following advantages: ● The calibration process is simple. The electronic calibrator only needs to be connected to the VNA once to complete the test items required by the dual-port calibration, without the need for www.siglent.com...
D. Characterization. View the characterization information stored in the ECal module Figure 6-39 ECal menu 6.10.2 ECal Config Press “Cal” on the front panel , Press Cal > ECal > ECal to enter the menu interface of ECal setting. www.siglent.com...
C. When “Orientation” is Auto, click “Next” to enter the automatic alignment directly. When “Orientation” is Manual, click “Next” to specify the calibration port and go to auto-calibration. 6.10.3 Confidence Check Press “Cal” on the front panel, press Cal > ECal > Confidence Check to enter the menu interface of Confidence Check. www.siglent.com...
Manual port setting procedure for Full 2-Port calibration Press “Cal” on the front panel, Press “Cal” > ECal > Orientation > Manual. Specify a test port of the VNA. Specify an ECal port for the port of the VNA you specified. www.siglent.com...
SHN900A User Manual Figure 6-42 Manual port setting 6.10.5 Characterization Press “Cal” on the front panel, press “Cal” > Cal > Characterization > Factory to view all the parameters of the stored Characterization in the ECal module. www.siglent.com...
Page 126
SHN900A User Manual Figure 6-43 The factory information of Cal Kit A. The date when the characteristics were measured B. The stimulus conditions when the characteristics were measured C. The information of the Connector type www.siglent.com...
Press the Marker button on the front panel, set the current marker in the Marker Setup submenu, we can make the following settings for the currently selected marker: Difference (delta) display: The difference display mode is closed by default, to open the www.siglent.com...
Page 128
Format and select the corresponding data format in the pop-up menu. The following data formats are available: ● Trace Default ● Lin Magnitude ● Log/Phase ● Phase ● ● Lin/Phase ● Re/Im ● Delay ● R+jx ● Real ● G+jB ● Imaginary ● Log Magnitude www.siglent.com...
Page 129
Click the Marker Table to select the On state, a table will appear at the bottom left to display all marker’s values, click the Marker Table again to select the Off option to close the marker table. www.siglent.com...
Marker → Delay: Referring to the phase slope of the current marker position, the line length is adjusted to the receiver input, this function helps to smooth the phase trace around the current marker. For the equipment without constant group delay in the measurement frequency span, www.siglent.com...
Domain command, select the search domain to be deleted in the pop-up menu, then click the Domain command again, and then click Delete in the pop-up menu. If the search domain of the marker is deleted, its search domain is automatically set to full span. www.siglent.com...
Page 132
If the current peak polarity is set to Both, the peak with the largest measured value among the effective positive peaks is searched. www.siglent.com...
Page 133
Use the Target Right → Search command in the target submenu to search the nearest valid target from the current marker position to the right. Use the Target Left ← Search command in the Target submenu to search the nearest valid target from the current marker position to the left. www.siglent.com...
Page 134
To turn off the bandwidth search, click BW Search Enable again and select the Off option. You can set whether to alarm when the bandwidth search fails in the Sound On www.siglent.com...
Page 135
(High - Low). ● Center frequency (Center): Frequency at the middle point between the lower frequency cut-off and higher frequency cut-off points. (High + Low)/2. ● Lower frequency cut-off point (Low): Lower frequency of 2 measurement points, both www.siglent.com...
The error is then subtracted from the DUT measurement. Conversion The vector network analyzer supports parameter conversion, which can convert the S parameter of the current trace to the required parameter mode. The vector network analyzer supports the following 8 conversion types. www.siglent.com...
Page 137
Y -Trans-Shunt: Admittance in parallel transmission Y 2 × √ × − ( + ● 1/S: Reciprocal of S parameter. ● Conjugation: Convert the measured value to a complex conjugate number. www.siglent.com...
1 and subtracting the value of the corresponding S11 data point. For a 201 point sweep, the calculation is repeated 201 times, once per point. The operation steps of the equation editor are as follows: Click Math → Analysis → Equation Editor enter the equation editor interface. www.siglent.com...
Page 139
→: Move the cursor to the right without clearing the character. ● Backspace: Clear the character while moving the marker to the left. ● Clear: Clear the currently entered formula. ● Numbers, operators, and constants: Numbers, common operators, and constants. www.siglent.com...
Page 140
Returns the square root of a, with phase angle in the half-open interval (-pi/2, pi/2] Tan (complex a) Takes a in radians and returns the tangent Constant 2.71828182845904523536 3.14159265358979323846 Advanced function Description A (complex a, complex b, complex c, complex F11 conversion = ((1+a)*(1-d) + b*c)/(2*b) www.siglent.com...
Limit table setting Click Math → Analysis → Limit and the pop-up dialog box is shown in the figure below. Limit test, sound type, limit table, global pass/fail can be set in this interface. www.siglent.com...
Page 148
Show table: Check this box to open a table at the bottom of the screen to create and edit limits. ● Load table: Call the saved limit table, The saved format of the limit table is CSV by default. www.siglent.com...
Page 149
Min: Below this limit line, the measurement fails. Delete: Delete limit line. ⚫ Begin stimulus: Frequency of the limit line’s starting point. End stimulus: Frequency of the limit line’s ending point. Begin response: Response of the limit line’s starting point. www.siglent.com...
Limit Test, Sound Type, Point Limit Table can be set in this interface. Figure 7-8 Point Limit test interface Point Limit test: ● Point Limit test on: Check this box to compare the data with the limit and display “pass” or “Fail” judgment result. www.siglent.com...
Page 151
Math → Analysis → Limit → Point Limit→ Show Table to open the point limit setting interface, as shown in the figure below. Figure 7-9 Point Limit setting interface Point Limit type: Unused: Invalid point limit. ⚫ ⚫ On: Open point test limit. ⚫ Delete: Delete point limit. Stimulus: Frequency of the point limit. www.siglent.com...
Click Math → Analysis → Limit → Ripple to open the ripple test setting interface, we can set ripple test, sound type, and ripple table in this interface. Figure 7-10 Ripple test setting interface Ripple test: ● Ripple test on: Check this box to set the ripple test to “on” state and display “pass” or “Fail”. www.siglent.com...
Page 153
Delete: Delete ripple test limit line. Begin stimulus: Frequency of ripple limit line’s starting point. End stimulus: Frequency of ripple limit line’s ending point. Max ripple: Maximum value of ripple test. Absolute: The difference between the maximum and minimum in the frequency band. www.siglent.com...
Click Math → Analysis → Limit → Bandwidth to open the broadband test setting interface, we can set bandwidth test, sound type, and target bandwidth in this interface. Figure 7-12 Bandwidth test setting interface Bandwidth test: ● Bandwidth test on: Check this box to set the bandwidth limit test state to on. www.siglent.com...
Time Domain Settings Click Math → Time Domain → Time Domain Setup → Transform to open the time domain transform setting interface, we can set the start time, stop time, center time, span, transform mode in this interface. www.siglent.com...
Page 156
The measurement range is inversely proportional to the frequency step. Set low pass frequencies: It can only be used in low pass mode. After clicking Set Low Pass Frequencies, the measurement range is inversely proportional to the starting frequency. Recalculate the start frequency and step www.siglent.com...
Stop time: Set the stop time of the gate. Center time: Set the center time of the gate. Time span: Set the time span of the gate. Gate type: Sets the type of filtering performed by the gating function. www.siglent.com...
Click Math → Time Gating → Gating Setup → Window to open the window setting interface, we can set the window size, The size of the window should be balanced between response resolution and dynamic range. Setting the minimum window can get the best response resolution, and setting www.siglent.com...
● Impulse width: Use the value of impulse width to change the window size. Figure 7-17 Diagram of maximum and minimum window 7.10.4 Coupling Overview Trace coupling allows to change the measured time-domain parameters and make all other measured www.siglent.com...
Page 160
● State (On/Off): State of the transform. ● Window: Kaiser Beta and pulse width parameter. ● Mode: Low pass pulse, low pass step, bandpass. ● Distance marker unit: When selected, all measured distance marker units are coupled. Gating parameters: www.siglent.com...
Auto: If the measurement parameter is S parameter, Reflection or Transmission will be selected automatically. If the measurement parameter is a non-S parameter, Reflection will be selected automatically. ● Reflection: Displays the distance from the source to the receiver and the return path, then divides by 2 (compensated return path). www.siglent.com...
In time-domain low-pass pulse and step transformation modes, users can choose to use the automatic extrapolation function provided by the instrument to determine the DC component value, or customize the extrapolation value. DC Value DC Value Setting Entry: Math → Time Domain → Time Domain Setup → Advance → DC Value www.siglent.com...
Page 163
In addition, the UI also provides convenient input of Open, Short, and Load configuration values, allowing users to freely choose appropriate extrapolation values based on the DUT type. www.siglent.com...
Please operate in the bottom toolbar of the TDR menu as far as possible. The function in the TDR option desends on the time domain transform, so changing settings in the right toolbars can lead to incorrect transform results. Don't close the eye diagram module while the eye diagram is drawing, or an unexpected error www.siglent.com...
To close the TDR option, use the order Math->TDR->TDR again, then the button “ Off ” will be selected, VNA will restore the state before the option opened. Click the button at the top right corner of the TDR toolbar will close the TDR option too. www.siglent.com...
The calibration operation will be illustrated in detail in the section “TDR calibration”. If you don't need to finish the setup in the wizard immediately, you can close the wizard. But the calibration is necessary before accurate measurement or analysis. www.siglent.com...
SHORT calibration kit to the port to finish the calibration. You can calibrate only one port at a click on the corresponding Port button, but you should finish the calibration of all ports to finish the task in the dialog. www.siglent.com...
At the third step, you can connect the LOAD calibration element to every port, and click the corresponding Port button to execute the calibration step. The step is optional, so it's not necessary to finish the calibration wizard. www.siglent.com...
TDR was opened. The current channel settings can be changed in the TDR toolbar at the bottom of the screen, usually in the Setup tab. Figure 8-6 TDR Setup Tab www.siglent.com...
Setup tab. It's a convenient way to set the suitable value by measuring the DUT length in the DUT Length dialog. Click the Auto button on the left of the textbox to open the dialog, connect www.siglent.com...
The velocity factor and dielectric constant can be set in the Velocity Factor and Dielectric Const. textboxes in the More Function bar of the Setup tab. Power Level 8.5.6 The power level is the power of the test signal transmitted to the DUT, which can be set in the Source www.siglent.com...
Hold/Stop. Continuous/Run means that the trigger signal starts and continuously sweeps. To switch the trigger mode to Continuous/Run, click the Run button at the top of the TDR toolbar. To switch the trigger mode to Single, click the Stop/Single button at the top of the TDR toolbar. www.siglent.com...
Option X&Y means that the horizontal and vertical axes of the current traces are set automatically. The method is the same as introduced above. All Trace means that the horizontal and vertical axes of all the traces are set automatically. The method is the same as introduced above. www.siglent.com...
/ impulse stimulus signal is transmitted to DUT at time zero, in a span. For a specified DUT, S parameters are functions of the signal frequency, while T parameters are functions of the time under a specified stimulus type. T parameters show the unit step / impulse www.siglent.com...
Page 175
To switch on or off the time domain transform of the current trace, click the pull-down menu in the left of the Measure line. To switch to balance or unbalance parameters, click the pull-down menu in the right of the Measure line. www.siglent.com...
The operation deletes all original traces and their settings, but the channel settings remain. There are three allocation methods to choose from: The option Mixed means that the traces in the time and frequency domain are allocated. The option All T means that only traces in the time www.siglent.com...
The time-domain gating settings in the TDR option can be changed in the Gating bar of the TDR/TDT tab. To switch on or off the time domain gating function, click the Gating checkbox. www.siglent.com...
In addition, the UI also provides convenient input of Open, Short, and Load configuration values, allowing users to freely choose appropriate extrapolation values based on the DUT type. www.siglent.com...
Delta time search is only available for the trace in the time domain, which searches for the difference between the time where two traces rise or fall to a specified relative level in respective transition edge. If successful, a label will be set to the relative level on both traces, and the results will be displayed www.siglent.com...
In the File pull-down menu at the top of the TDR toolbar, there are some shortcuts for file operation and data output. The order Save State... is used to save the current state and calibration data as a .CSA file, and www.siglent.com...
The jitter injection and statistical eye diagram function are provided to analyze the influence of the jitter in the input signal on the transmission performance. The mask test on the eye diagram and preinstalled mask patterns are a convenient method of estimating whether the eye diagram meets the design requirements. www.siglent.com...
The initial condition of the LFSR is random, PRBS generated becomes random to find the worst bit pattern of n bits for transmission performance. Eye diagram simulation always includes all n-bit input patterns to show the worst transmission www.siglent.com...
It's effective to widen the eye by reducing the rise time properly. But too small a rise time leads to ringing phenomena at the logic level of the output www.siglent.com...
Eye/Mask tab at the bottom of the TDR toolbar. To change the scale or offset values in Manual scale mode, set the value in the Scale/Div or Offset textbox. The Offset value here is the value that the center vertical scale line refers to. www.siglent.com...
To switch on or off the mask test, click the Mask Test checkbox in the Scale/Mask bar of the Eye/Mask tab at the bottom of the TDR toolbar. Jitter & Statistical Eye Diagram 8.8.7 Jitter is the transient deviation from the corresponding ideal position of a signal over successive trigger www.siglent.com...
Page 186
To set the probability limit to display in the statistical eye diagram, click the Display Limit pull-down www.siglent.com...
/Run, the viewpoint will be set to responses automatically. Click the ratio button after the DUT icon, switch the viewpoint to responses, and set the trigger mode to Continuous /Run. The transmission parameters show the responses processed by emphasis /de- emphasis, DUT, and equalization. www.siglent.com...
The TDR option provides a port de embedding function, which is the same as the port de embedding function in the fixture measurement function. By clicking the Enable button on the left side of the De embedding tab, the TDR option port de embedding function main switch can be turned on/off. www.siglent.com...
The equalizer system function provided by the TDR option is as follows ; By adjusting the DC gain and zero pole position, the system function of the equalizer can be modified to simulate and evaluate different linear equalization strategies. K(s + ω H ( s ) = (s + ω )(s + ω www.siglent.com...
Page 190
The file format can refer to the following examples: !SIGLENT Technologies !VNA TDR-option Equalization File # Hz dB 1000000000,-1.53E+01,-3.27E-01...
If the zero input response of DUT obeys some statistical law, and the mean value in the time domain is zero (such as obeying Normal distribution); the average function can be enabled and the average frequency can be appropriately increased to suppress the impact of such interference on the measurement by averaging the responses measured multiple times. www.siglent.com...
Enter the data rate of the signal emitted by the device in the Data Rate fine-tuning box; if the data rate of the signal emitted by the device is unknown, an approximate value can be obtained using the cursor on the frequency measurement results. The data rate error should be less than ± 0.5% to www.siglent.com...
Page 193
In addition, after changing the DUT length or scanning frequency setting in Hot TDR mode, the original Hot TDR setting becomes invalid and may need to be reconfigured to eliminate the influence of interference signals. Figure 8-19 Hot TDR setting www.siglent.com...
Average Type, Current Marker operation. C. Display the SA setting dialog box SA parameter reset, SA processing flow chart. D. SA Measurement items E. Indicate and control the main sweep parameters Such as starting frequency, bandwidth resolution/video resolution, and termination frequency. www.siglent.com...
If the show Setup Dialog check box is deselected, the SA Setup dialog box will not be displayed when the SA function is enabled. If the user wants to modify the SA parameters, there are two ways to enter the SA Setup dialog box. www.siglent.com...
SA Tab Setting is mainly related to Spectrum analysis frequency setting. which can be set through the SA Setup dialog box or by pressing the [Freq] key on the front panel to enter the frequency setting menu, as the figure shown below. If the frequency is changed, the frequency sweep will restart. www.siglent.com...
Page 197
The span and center frequency vary with the start frequency when the Span does not reach the minimum. 9.4.1.2 Stop Frequency Set the stop frequency of the Spectrum Analyzer. The start frequency and the stop frequency will display at the bottom of the grid respectively. www.siglent.com...
Page 198
CF step size. 9.4.1.6 Num of Points The number of sweep points represents the number of sweep and trace displayed points (2~20001) More sweep points will improve the resolution of waveform, but also affect the minimum sweep time, www.siglent.com...
Reducing the RBW will increase the frequency resolution. But lead to a longer sweep time ● (influenced by both RBW and VBW when the sweep time is in automatic mode). ● RBW varies with the Span/RBW setting in Auto RBW mode. www.siglent.com...
Page 200
In this Average type, all filtering and averaging processes work on the voltage of the envelope of the signal. This scale is suitable for observing rise and fall behavior of AM or pulse-modulated signals such as radar and TDMA transmitters. www.siglent.com...
The Source Tab of SA Setup is the configuration for internal sources as signal sources. Figure 9-6 Source Tab Port Powers Coupled (checked) the power levels are the same at each test port. Set power at any test port and all test ports change to the same power level. SA Source Setup www.siglent.com...
Page 202
When the internal source is used for the Spectrum analysis signal sources, the sweep type, source frequency and the port power level of the source can also be set by pressing the [Power] key on the front panel to enter the port power setting menu. As the figure shown below: www.siglent.com...
The Advanced Tab is the configuration of parameters related to signal processing for Spectrum analysis. Which can be set through the SA Setup dialog box or by pressing the [AvgBW]>BW on the front panel to enter the setting menu, as the figure shown below. www.siglent.com...
Page 204
None: Selects 1 acquisitions, and mirror suppression is not performed. Min: Selects 3 acquisitions. Normal: Selects 4 acquisitions. Better: Selects 5 acquisitions. Max: Selects 6 acquisitions. www.siglent.com...
Standard: The maximum attenuation mode, the average noise level is higher. Trace setup 9.4.5 Click the trace status area on the upper left corner of the interface, and the trace setting drop-down menu will pop up for trace setting operations. www.siglent.com...
Page 206
Some common applications include FM Deviation, AM NRSC, and frequency hopping or drift. The type identifier is “M”. ● Min Hold Display the minimum value from multiple sweeps for each point of the trace and www.siglent.com...
Page 207
Blank: Trace data is no longer refreshed or displayed Modifying the trace state so that the trace does not refresh will immediately stop the refresh state of the current frame of data. Modify the trace status to refresh the trace and restart measurement and scanning. www.siglent.com...
Page 208
User can manually select an appropriate detection type based on actual requirements and application scenarios to ensure measurement accuracy, or set the detection type to automatic. www.siglent.com...
50MHz. and mark the S22 trace by pressing the [Marker] key on the front panel; Press [Marker] > Marker Function > Marker → SA to enable the SA function. You can view the frequency spectrum of 1GHz point of the S22, as figure shown below: Figure 9-11 Marker → SA www.siglent.com...
9.5.2.1 Integration BW Set the frequency width of the channel to be tested and the power of the channel is the power integral within this bandwidth. You can use the numeric keys, knob or direction keys to modify this parameter. www.siglent.com...
(distance between adjacent channels and the center point of the main channel). Calculate the power of each channel using the same method as the channel power algorithm. The ratio of adjacent channel power to main channel power is the www.siglent.com...
Page 212
Set the bandwidth of adjacent channels. 9.5.3.3 Adj Chn Space The center frequency spacing between the main channel and adjacent channels. Adjusting the distance between adjacent channels will simultaneously adjust the distance between the previous and subsequent channels and the main channel. www.siglent.com...
Two vertical lines perpendicular to the X-axis represent the occupied span of the power percentage. The value of the Y-axis is the power value that occupies the bandwidth. The bandwidth and power of the span will be displayed in the upper right corner. www.siglent.com...
Page 214
● Power: the power according to the specified power ratio. ● Total Power: the whole span power. ● Transmit Freq Error: The difference between the center frequency of the channel and the center frequency of the analyzer. www.siglent.com...
Page 215
SHN900A User Manual ● Percent: Power ratio. www.siglent.com...
Frequency Offset Mode (FOM) enables the SNA internal RF signal source and SNA port receiver to operate at different frequencies. To realize the measurement of nonlinear characteristics of the device. 10.2.1 Frequency Offset settings Press [Freq] > Freq Offset…to enter the frequency offset function setting dialog box. www.siglent.com...
Page 217
Coupled Source and Receiver settings are mathematically derived from the Primary settings using Multiplier, Divisor, and Offset values. ● Uncoupled Source and Receiver settings are entered independently, without reference to Primary settings. When Uncoupled, Source and Receiver Ranges can use separate sweep www.siglent.com...
Page 218
-100 to 100. B. Divisor Specifies (along with the multiplier) the value to multiply the stimulus. The value is an integer from -100 to100. C. Offset Specify the absolute offset frequency (Hz). For the mixer, this will be the LO frequency. www.siglent.com...
Page 219
When sweep type is Segment Sweep, the segment table edits are made exactly like the standard segment table. In segment sweep mode: ● The OK button is NOT available until the total number of data points for all segments matches the number of Primary data points. www.siglent.com...
“New Channel” then click OK. A CAT measurement is displayed on the current channel or on a new channel and New Window. 11.3 Freq/Dist Click Freq/Dist to open the Freq/Dist setting interface, and set the frequency or distance range of the current measurement. Distance range can only be set in DTF/TDR. www.siglent.com...
Page 221
Stop Distance: Specify the stop distance of the measurement result to be displayed. It can not be set above max meas distance. The frequency range settings will affect the max meas distance, Refer to 11.4.1.2 Max Measurement Distance for details. www.siglent.com...
Besides, the cable length, working frequency range, and the attenuation and velocity factor should be acknowledged in advance. DTF measurement settings: In CAT measurement mode, click Meas > Distance to Fault to open the DTF setting interface and select DTF measurement. www.siglent.com...
Page 223
In CAT measurement mode, click Format to open the data format setting interface and select the data format. DTF measurement supports three data formats: ● Log Mag: Faults are displayed on the Y-axis in return loss format. expressed in unit dB. ● Lin Mag: Faults are displayed on the Y-axis in linear(unitless)format. www.siglent.com...
Page 224
10 dB of power. Considering DTF measurement is perfomed with 1 port, the signal traveled down the cable and then back, for a total loss of 20 dB. Cable Loss settings: www.siglent.com...
Page 225
Therefore, the window should be applied to gradually reduce the marginal frequency response and control the side lobe formed by the truncation. Click Meas > Distance to Faul > DTF[Port1]/DTF[Port2] > Meas Setup > Kaiser Beta/DTF Window to open the window setting interface and set the window. www.siglent.com...
It helps quickly locate the fault point on the cable, and preliminarily identify the fault type.If there is multiple mismatchs in the cable. The measurement steps are the same with DTF. www.siglent.com...
Page 227
Velocity Factor is a the ratio of the velocity of the electric signal in the cabl to that in the vacuum. For example, A polyethylene dielectric cable has VF =0.66 and a cable with PTFE dielectric has VF =0.7. www.siglent.com...
Page 228
Sidelobe level will be suppressed by applying window function, the larger the Kaiser beta is, the more obvious the suppression effect will be, but at the same time, it will increase the rise time of stimulus signal, thus reducing the resolution www.siglent.com...
Page 229
Gate Type: Set the type of filtering perfomed by the gating function. • Band Pass: Keep the response in the gating span. • Notch: Remove reponse using the gating span. Gate Shape: Set the filter characteristics of the gating function. There are four options: minimum, www.siglent.com...
A 2-port Insertion Loss measurement is usually more accurate than a 1-port Cable Loss measurement. Insertion Loss Operating Steps: In the CAT measurement mode, click Meas > Insertion Loss to open the Insertion Loss setting interface, and select the Insertion Loss measurement. www.siglent.com...
0 dB return loss is displayed.When measuring a LOAD, very little power is reflected and values of 40 dB to 60 dB are displayed. Return Loss Operating Steps: In the CAT measurement mode, click Meas > Return Loss to open the Return Loss setting interface, and select the Return Loss measurement. www.siglent.com...
Average cable loss can be measured, and Avg Cable Loss satisfies the formula: Avg Cable Loss = ∑ (measured cable loss)/number of points Cable Loss Operating Steps: In the CAT measurement mode, click Meas > Cable Loss to open the Cable Loss setting interface, and select the Cable Loss measurement. www.siglent.com...
The formula of VSWR is: (1+r)/(1-r) (where R is the reflection coefficient). Only valid for reflection measurement. VSWR Operating Steps: In the CAT measurement mode, click Meas > VSWR to open the VSWR setting interface, and select the VSWR measurement. www.siglent.com...
TouchStone file names are all suffixed with .SnP. N represents the number of ports S2p represents a 2-port network. Take the TouchStone file of a Two-port network as an example. This file is a plain text file that can be opened directly with Notepad. The S parameters of the Two-port www.siglent.com...
Page 236
Recall status of equipment: Use the Recall State command in the Recall submenu to select the required equipment state in the .sta file format. ● Recall the status and calibration data of equipment: Use the Recall State + Cal command in www.siglent.com...
Page 237
Recall calibration data: Using the Recall Cal command from the Recall submenu, select to call the required calibration data in a. Cal file format. File management: Click File Browser command to open the file browser, File management can be carried out in the file browser. Figure 12-2 File management interface www.siglent.com...
Figure 13-1 System setting interface 13.1 System Configuration 13.1.1 File Browser Click File Browser command to open the file browser, File management can be carried out in the file www.siglent.com...
13.1.2 Firmware Upgrade Follow this procedure to update the instrument firmware: Download the firmware package from an official SIGLENT website. Extract and copy the .ADS file into the root directory of an USB stick. Plug the USB stick into the USB Host connector. Press System > “System” -> “Upgrade…” ;...
Use the Screensaver command in the System submenu to set the screen saver parameters. 13.1.6 System language The Language command in the Language submenu can be used to change the language of the equipment. Simplified Chinese and English are supported. www.siglent.com...
The Reset menu button can restore the VNC port to the default state. 13.2.1.5 Web Setting You can set the Web password in the Web Setting submenu, and you need to enter the web password when remotely controlling the analyzer through the web. www.siglent.com...
Port 1: RF port 1, which can also be used as a Bias output port. • Port 2: RF port 2, which can also be used as a Bias output port. 13.2.2.2 Bias voltage The range of Bias voltage is 12V~32V, and the step value is 0.1. www.siglent.com...
13.2.5 GPS Receiver Click System > I/O Setting > GPS Receiver to open the GPS Receiver setting interface. 13.2.5.1 GPS Switch When GPS is on, enable GPS to start star search, and display "GPS Display information" below quick action bar. www.siglent.com...
Preset operation and related settings can be performed in Preset submenu. Preset: Use the Preset command to reset immediately according to the setting reset options. Preset Option: Use the Preset Option command to set the reset options, and to determine the preset source: www.siglent.com...
If the check box is not checked, the normal deletion mode will be used. Figure 13-6 Select the saved file ● Configuration files and User data: If user select both, the equipment is restored to the factory www.siglent.com...
Clear to suppress the display of messages. You can still view them in the View Message. ● Enable Power Unlevel Detection (Selected by default). Check to enable the power unlevel detection. Clear to close. 13.4.4 View Message In the View Message submenu, we can open the message log dialog. www.siglent.com...
Press Enter to confirm your input and terminate the license key input. Or load the .lic file and press “Scan U-disk” to select the corresponding .lic file in the memory. 13.8 External Ports Used to define external logical port, source port, reference receiver port and test receiver port. www.siglent.com...
14.1 Ordering and activating the options There are two ways for you: Pre-activate the options by Siglent factory. If you order a instrument and options, Siglent factory will activate the options for you before delivery. Post-activate the options by yourself.
SIGLENT will provide repair or replacement service according to the detailed provisions of the warranty. For service or a complete copy of the warranty, please contact your nearest SIGLENT sales and service office. SIGLENT makes no other warranty, express or implied, except as provided in this summary or the applicable warranty, including but not limited to the implied warranty of merchantability and special applicability.
Page 251
DC power supplies, electronic loads and other general purpose test instrumentation. Since its first oscilloscope was launched in 2005, SIGLENT has become the fastest growing manufacturer of digital oscilloscopes. We firmly believe that today SIGLENT is the best value in electronic test & measurement. Headquarters: SIGLENT Technologies Co., Ltd...
Need help?
Do you have a question about the SHN900A Series and is the answer not in the manual?
Questions and answers