Installation Digital Matrix
USER MANUAL
50-0215-0111
MIMO88
EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MMIMO88 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ecler MMIMO88

  • Page 1 MIMO88 DIGITAL MATRIXES Installation Digital Matrix USER MANUAL 50-0215-0111 MIMO88...
  • Page 2: Table Of Contents

    INDEX HARDWARE 3-19 ……………………………….……………………………………….…..………………...…….…..… IMPORTANT REMARK ......................3 IMPORTANT SAFETY INSTRUCTIONS ................3 IMPORTANT NOTE ........................5 INTRODUCTION ........................5 INSTALLATION .......................... 6 Location, assembly, ventilation ..................... 6 Connection to an AC outlet and switching on ............... 6 Signal input connections ........................
  • Page 3: Hardware

    IMPORTANT REMARK The lightning flash with arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
  • Page 4 8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 9. Do not defeat the safety purpose of the polarized or grounding type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong.
  • Page 5: Important Note

    IMPORTANT NOTE Thank you for choosing our Ecler MIMO88 Installation Digital Matrix! VERY IMPORTANT It is to carefully read this manual and to fully understand its contents before any connection in order to maximize your use and get the best performance from this equipment.
  • Page 6: Installation

    The MIMO88 programming is done with EclerNet Manager application. Please refer to the EclerNet Manager software manual at www.ecler.com for more information. INSTALLATION Location, assembly, ventilation The MIMO88 has been especially designed to be installed in a standard 19" rack, taking up 1U.
  • Page 7: Signal Input Connections

    Input signal type selection and management are carried out from EclerNet Manager application. Please refer to the EclerNet Manager software manual at www.ecler.com for more information. Signal input connectors are 3 position screw terminal block. The wiring is: Hot or direct signal >...
  • Page 8: Ethernet Port For Programming And Control

    • Possibility of direct connection (point to point) between a computer and a MIMO88 unit. • Connection to third party other devices. (Crestron, AMX, Vity, Medialon, etc. Registered trademarks of their manufacturers). Protocol used: Ecler TP-NET. the TP-NET protocol manual for more information.
  • Page 9: Remote Ports 1 And 2 For Digital Remote Controls

    Refer to the remote device documentation (WPNETTOUCH, MPAGE16, etc) for more information about your connection and controls. Please refer to the EclerNet Manager software manual at www.ecler.com for more information about MIMO88 programming to manage remote devices connected to REMOTE1 or REMOTE2.
  • Page 10: Gpi Remote Control Ports

    MIMO88 function, as for example: • Input, output channel or matrix crosspoint volume remote control by means of a WPaVOL physical knob or an Ecler WP Series WPaVOL-IR remote control • MUTE or SOLO activation/deactivation by means of a switch or contact closure •...
  • Page 11: Gpo Remote Control Ports

    Connecting cables can be up to 500 meters with a minimum section of 0.5 mm Consult your ECLER dealer or www.ecler.com about the WP series remote control wall panels and other accessories available for connection to the REMOTE/VCA port. GPO Remote Control Ports The rear panel of the MIMO88 offers 8 NO/NC (normally open/ normally closed) relay outputs (17).
  • Page 12: Front Panel Controls And Led Indicators

    In 16x16 mode both MIMO units receive the same signal. The monitored signal is selected with EclerNet Manager control software. Please refer to the EclerNet Manager software manual at www.ecler.com for more information. • Input LED indicators: indicate the presence of audio signal at the unit’s input, and...
  • Page 13: Cleaning

    • If there is a communication error with the MASTER, the LED quickly toggles between orange (50ms) and red (200ms) • If no MASTER is connected (or if connected equipment is another SLAVE), the LED slowly toggles between orange (800ms) and red (200ms) o POWER: illuminates when the unit is in operation.
  • Page 14: Function Diagram

    FUNCTION DIAGRAM...
  • Page 15: Technical Characteristics

    TECHNICAL CHARACTERISTICS MIMO88 2 x 32/64bit Sampling Rate 48kHz Latency IN to OUT <2.9ms (+1ms for 16x16) Converters Resolution 24bit AKM Dynamic Range AD:110dB, DA: 115dB Analogue 8+8 Input/Output Terminal block (Symmetrical) 2 monitor output Terminal block (Symmetrical) Headphones related Jack ¼...
  • Page 16 Low & High Pass 6/12 dB/oct All Pass 1/2 order High & Low pass output Crossover filters (x8) Bypass On-Off Butterworth in 6/12/18/24 dB/oct Bessel in 12/18/24 dB/oct Linkwitz-Riley in 12/24 dB/oct Input Noise Gate (x8) Bypass On-Off Threshold: from –80 dBV to +18 dBV Depth: 0 dB to 80 dB Attack time: from 0,1 ms.
  • Page 17 Supply Mains 90-264VCA 47-63Hz Power consumption 45VA Miscellaneous Management Connectivity Ethernet Base-Tx 10/100Mb Auto X-Over CAT5 up to 100m. Expansion LINK BUS (16x16 ch.) Proprietary over CAT5, Xover cable up to 100m. Remote Bus 2, over twisted pairs; up to 1km (see specific specs.) 8, from 0 to 10VDC or TTL level 8, 3 poles isolated relay;...
  • Page 18: Block Diagram

    10 BLOCK DIAGRAM...
  • Page 19: Software

    TP-NET PROTOCOL SOFTWARE Third-Party NET USER MANUAL 50-0216-0113 TP-NET Protocol EN...
  • Page 20: Tp-Net Protocol Introduction

    • Stop bits: 1 • Flow control: None In case the Ecler device has an Euroblock connector for the RS-232 interface, the serial cable wiring, from the device’s connector to a standard DB9 serial interface connector, must be the following: The protocol is simple and direct, making it easy to read, write and modify the generated code.
  • Page 21 The available messages are built with one or more fields separated with blank spaces ( = blank space): <TYPE> [PARAM1] [PARAM2] [PARAM3] [PARAM4][LF] The first field (TYPE) defines the message type and then, the required parameters for it (each kind of message requires a given number of parameters). The field TYPE can have these values:...
  • Page 22 messages don’t have an automatic acknowledgement with a DATA message sent from the EclerNet device after it has processed the command. The client must update the values itself and must send the needed message if it requires confirmation from the device. NOTES: •...
  • Page 23: Mimo88 Digital Matrix

    12 MIMO88 DIGITAL MATRIX IMPORTANT NOTE: The communication must be started with the client sending the first message SYSTEM CONNECT to the EclerNet device. Otherwise, the commands from the client to the EclerNet device will be ignored. See TP-NET PROTOCOL INTRODUCTION chapter for additional information.
  • Page 24 XMUTE <Input Channel> <Output Gets the current MUTE status of a Matrix Point Channel> <Input Channel> Gets the VU-meter value of an Input Channel <Output Gets the VU-meter value of an Output Channel Channel> <Input> Gets the current value of a General Purpose Input <Output>...
  • Page 25 TYPE PARAM1 PARAM2 PARAM3 PARAM4 DESCRIPTION PRESET <Preset Number> Sets the current PRESET ILEVEL <Input Channel> <Level> Sets the current LEVEL of an Input Channel OLEVEL <Output Channel> <Level> Sets the current LEVEL of an Output Channel XLEVEL <Input Channel> <Output <Level>...
  • Page 26 XLEVEL <Input Channel> <Output <Value> Decreases the current LEVEL of a Matrix point by Channel> Value (Value can range from ±1 to ±100) SUBSCRIBE Subscribes to all VU-meters <Input Channel> Subscribes to an Input Channel VU-meter <Output Channel> Subscribes to an Output Channel VU-meter UNSUBSCRIBE Unsubscribe to all VU-meters <Input Channel>...
  • Page 27 TYPE PARAM1 PARAM2 PARAM3 PARAM4 DESCRIPTION DATA PRESET <Preset Number> Shows the current PRESET ILEVEL <Input Channel> <Level> Shows the current LEVEL of an Input Channel OLEVEL <Output Channel> <Level> Shows the current LEVEL of an Output Channel XLEVEL <Input Channel> <Output Channel>...
  • Page 28: Error Codes For Eclernet Devices

    13 ERROR CODES FOR ECLERNET DEVICES 13.1 COMMON ERROR CODES (to all EclerNet - TP-NET compatible devices) ERROR ID DESCRIPTION TPNET_ERROR_NONE = 0, TPNET_ERROR_INVALID_FIELD_TYPE, TPNET_ERROR_INVALID_FIELD_PARAM1, TPNET_ERROR_INVALID_FIELD_PARAM2, TPNET_ERROR_INVALID_FIELD_PARAM3, TPNET_ERROR_INVALID_FIELD_PARAM4, 13.2 MIMO88 SPECIFIC ERROR CODES ERROR ID DESCRIPTION UDP_ERROR_TIMEOUT_PONG, UDP_ERROR_CONNECT_WHILE_CONNECTED, UDP_ERROR_DISCONNECT_WHILE_UNCONNECTED, UDP_ERROR_INVALID_CLIENT_IP, UDP_ERROR_MESSAGE_TOO_LONG, UDP_ERROR_UNSUPPORTED_MESSAGE, UDP_ERROR_UNSUPPORTED_PRESET_NUMBER,...
  • Page 29 NEEC AUDIO BARCELONA S.L. reserves the right to make changes or improvements in the design or manufacturing that may affect these product specifications. For technical queries contact your supplier, distributor or complete the contact form on our website, Support / Technical requests. Motors, 166‐168 08038 Barcelona ‐ Spain ‐ (+34) 932238403 | information@ecler.com www.ecler.com...