breaker (RCD) with a rated Danger! When using the equipment, a few safety pre- fault current of no more than cautions must be observed to avoid injuries and 30 mA (according to VDE 0100 damage. Please read the complete operating instructions and safety regulations with due care.
There is a risk of the liquid 3. Proper use • becoming contaminated by The equipment you have purchased is designed escaping lubricant. to pump water with a maximum temperature of 35 °C. This equipment must never be used for The pump is not allowed to be •...
Fig. 9) to the connection actually used in order not to reduce the pumping rate unnecessarily. Flexible hoses must be fastened to the universal GE-DP 7330 LL ECO hose connection with a hose clip (not included in Mains connection ......230 V ~ 50 Hz the scope of supply).
7. Replacing the power cable Setting the On/Off switching point: The ON/OFF switching point can be infi nitely ad- justed with the height adjustment facility. For this Danger! purpose you must fi rst slacken the screw (Fig. 3, If the power cable for this equip- Item 3).
Identification number of the machine • Replacement part number of the part required For our latest prices and information please go to www.Einhell-Service.com 9. Disposal and recycling The equipment is supplied in packaging to pre- vent it from being damaged in transit. The raw materials in this packaging can be reused or recycled.
11. Troubleshooting guide Faults Cause Remedy The equipment - Power supply not connected - Check power supply does not start - Floating switch does trigger - Raise position of fl oating switch The equipment - Intake sieve clogged - Clean intake sieve with water jet does not pump - Discharge hose kinked - Unkink the hose...
Page 11
The reprinting or reproduction by any other means, in whole or in part, of documentation and papers ac- companying products is permitted only with the express consent of the Einhell Germany AG. Subject to technical changes - 21 - Anl_GE_DP_7330LL_5220LL_SPK13.indb 21...
* Not necessarily included in the scope of delivery! In the eff ect of defects or faults, please register the problem on the internet at www.Einhell-Service.com. Please ensure that you provide a precise description of the problem and answer the following questions in all cases: •...
5. To make a claim under the guarantee, please register the defective device at: www.Einhell-Service.com. Please keep your bill of purchase or other proof of purchase for the new device. Devices that are returned without proof of purchase or without a rating plate shall not be covered by the guarantee, because appropriate identifi...
Page 14
Samræmisyfi rlýsing: Við útskurðum samræmi við EU-reglugerð og Οδηγία Εε και πρότυπα για τα προϊόντα stöðlum fyrir vörutegund Declaração de conformidade: Declaramos a conformidade de acordo com a diretiva CE e normas para o artigo Schmutzwasserpumpe* GE-DP 7330 LL ECO (Einhell) 2014/29/EU 2006/42/EC Annex IV 2005/32/EC_2009/125/EC Notifi...
Champions Business Park, First Floor Unit 10, Arrowe Brook Rd, Upton, Wirral CH49 0AB, United Kingdom declare the conformity to UK standards and legislation was assessed for: Dirt Water Pump GE-DP 7330 LL ECO (Einhell) UK legislation Simple Pressure Vessels (Safety) Regulation...
Page 16
Samræmisyfi rlýsing: Við útskurðum samræmi við EU-reglugerð og Οδηγία Εε και πρότυπα για τα προϊόντα stöðlum fyrir vörutegund Declaração de conformidade: Declaramos a conformidade de acordo com a diretiva CE e normas para o artigo Schmutzwasserpumpe* GE-DP 5220 LL ECO (Einhell) 2014/29/EU 2006/42/EC Annex IV 2005/32/EC_2009/125/EC Notifi...
Page 17
Champions Business Park, First Floor Unit 10, Arrowe Brook Rd, Upton, Wirral CH49 0AB, United Kingdom declare the conformity to UK standards and legislation was assessed for: Dirt Water Pump GE-DP 5220 LL ECO (Einhell) UK legislation Simple Pressure Vessels (Safety) Regulation...
Need help?
Do you have a question about the GE-DP 7330 LL ECO and is the answer not in the manual?
Questions and answers