Download Print this page
EINHELL GE-DP 7535 N LL ECO Original Operating Instructions
EINHELL GE-DP 7535 N LL ECO Original Operating Instructions

EINHELL GE-DP 7535 N LL ECO Original Operating Instructions

Dirty water pump
Hide thumbs Also See for GE-DP 7535 N LL ECO:

Advertisement

Quick Links

D
Originalbetriebsanleitung
Schmutzwasserpumpe
GB
Original operating instructions
Dirty Water Pump
F
Instructions d'origine
Pompe eaux usées
I
Istruzioni per l'uso originali
Pompa per acque re ue
DK/
Original betjeningsvejledning
N
Spildevandspumpe
S
Original-bruksanvisning
Smutsvattenpump
CZ
Originální návod k obsluze
Kalové Čerpadlo
SK
Originálny návod na obsluhu
Kalové čerpadlo
NL
Originele handleiding
Vuilwaterpomp
E
Manual de instrucciones original
Bomba de agua sucia
13
Art.-Nr.: 41.816.00
Anl_GE_DP_7535_N_LL_ECO_SPK13.indb 1
GE-DP 7535 N LL ECO
FIN
Alkuperäiskäyttöohje
Likavesipumppu
SLO
Originalna navodila za uporabo
Črpalka za umazano vodo
H
Eredeti használati utasítás
Szennyvízszivattyú
RO
Instrucţiuni de utilizare originale
Pompă de ape uzate
GR
Πρωτότυπες Οδηγίες χρήσης
Αντλια ακαθαρτου νερου
P
Manual de instruções original
Bomba de água suja
HR/
Originalne upute za uporabu
BIH
Pumpa za prljavu vodu
RS
Originalna uputstva za upotrebu
Pumpa za prljavu vodu
PL
Instrukcją oryginalną
Pompa zanurzeniowa do brudnej
wody
TR
Orijinal Kullanma Talimat
Pis su pompasi
EE
Originaalkasutusjuhend
Heitveepump
I.-Nr.: 21013
14.11.2023 08:51:09

Advertisement

loading
Need help?

Need help?

Do you have a question about the GE-DP 7535 N LL ECO and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for EINHELL GE-DP 7535 N LL ECO

  • Page 1 GE-DP 7535 N LL ECO Originalbetriebsanleitung Alkuperäiskäyttöohje Schmutzwasserpumpe Likavesipumppu Original operating instructions Originalna navodila za uporabo Dirty Water Pump Črpalka za umazano vodo Instructions d’origine Eredeti használati utasítás Pompe eaux usées Szennyvízszivattyú Istruzioni per l’uso originali Instrucţiuni de utilizare originale Pompa per acque re...
  • Page 2 - 3 - Anl_GE_DP_7535_N_LL_ECO_SPK13.indb 3 14.11.2023 08:51:12...
  • Page 3 ca. 25mm (1“) ca. 33,3mm (1“) AG ca. 38 mm (1 1/2“) min. 10 cm - 4 - Anl_GE_DP_7535_N_LL_ECO_SPK13.indb 4 14.11.2023 08:51:14...
  • Page 4 customer service centers, or by a Danger! When using the equipment, a few safety pre- similarly trained person in order cautions must be observed to avoid injuries and to prevent hazards. damage. Please read the complete operating instructions and safety regulations with due care. Keep this manual in a safe place, so that the in- Danger! formation is available at all times.
  • Page 5: Layout And Items Supplied

    wet conditions. packaging and/or transportation braces (if available). If there is a risk of flooding, • • Check to see if all items are supplied. • place the plug-in connections Inspect the equipment and accessories for transport damage. in an area which is safe from •...
  • Page 6: Technical Data

    The equipment is to be used only for its prescri- Be sure to consult a professional plumber if you bed purpose. Any other use is deemed to be a have any doubt. case of misuse. The user / operator and not the manufacturer will be liable for any damage or inju- The equipment must be fastened to the suspensi- ries of any kind caused as a result of this.
  • Page 7: Operation

    6. Operation 6.2.2 Dirty water mode (Fig. 4b) In dirty water mode the equipment can be set for three diff erent sizes (15/25/35 mm). 6.1 Using for the  rst time • Turn the equipment clockwise and pull it You can put the equipment into operation after upwards by the handle to the setting that you you have thoroughly read the installation and ope- require.
  • Page 8: Disposal And Recycling

    Identification number of the machine • Replacement part number of the part required For our latest prices and information please go to www.Einhell-Service.com 9. Disposal and recycling The equipment is supplied in packaging to pre- vent it from being damaged in transit. The raw materials in this packaging can be reused or recycled.
  • Page 9: Troubleshooting Guide

    11. Troubleshooting guide Faults Cause Remedy The equipment does - Power supply not connected - Check power supply not start - Floating switch does trigger - Raise position of  oating switch The equipment does not - Intake sieve clogged - Clean intake sieve with water jet pump - Discharge hose kinked...
  • Page 10 The reprinting or reproduction by any other means, in whole or in part, of documentation and papers ac- companying products is permitted only with the express consent of the Einhell Germany AG. Subject to technical changes - 21 - Anl_GE_DP_7535_N_LL_ECO_SPK13.indb 21...
  • Page 11: Service Information

    * Not necessarily included in the scope of delivery! In the eff ect of defects or faults, please register the problem on the internet at www.Einhell-Service.com. Please ensure that you provide a precise description of the problem and answer the following questions in all cases: •...
  • Page 12 We draw attention to the restrictions of this guarantee concerning wear parts, consumab- les and missing parts as presented in the service information included in this operating manual. Warrantor/ Service: Einhell UK Ltd, Unit 10, 1st Floor, Champion‘s Business Park, Arrowe Brook Road, Upton, Wirral, CH49 0UQ - 23 - Anl_GE_DP_7535_N_LL_ECO_SPK13.indb 23...

This manual is also suitable for:

41.816.00