Mount the pump to suit the type of installation planned.
Very heavy lubricants may require an inductor plate.
See page 14 for the mounting hole layout and
dimensions
Install the air line accessories in the approximate order
shown in the Typical Installation. Install a bleed-type
master air valve (B) within easy reach of the pump,
upstream from the air regulator. Install an air filter (C)
to remove harmful dirt and moisture from your
compressed air supply. For automatic air motor
lubrication, install an air line oiler (D) close to the pump
air inlet. Install an air regulator (E) to control pump
speed.
Typical Installation
Key
A
Grounded Air Line
B
Bleed-type Master Air Valve
C
Air Filter
D
Air Line Oiler
E
Air Regulator
F
Grounded Dispensing Hose
G
Dispensing Valve
H
Elevator Assy. With Inductors
J
Ground Wire
A
B
Fig. 2
6
306674
Installation
C
D
E
H
WARNING
A bleed-type master air valve (B) is required to
shut off and relieve air pressure that may be
trapped in the air motor. Trapped air could cause
the pump to cycle unexpectedly and cause serious
bodily injury, including amputation.
Be sure the air hose is properly sized to deliver an
adequate supply of air to the motor. Refer to the
Technical Data on page 15.
Connect a dispensing hose to the 3/8 npt(f) pump
outlet. Install an appropriate gun or dispensing valve to
the hose.
Ground the pump as explained on page 5.