Check Daily - Mosa GE 20 PS SX Use And Maintenance Manual

Table of Contents

Advertisement

START AND STOP (EP6)

Check daily

NOTE
!
Do not alter the primary conditions of regulation
and do not touch the sealed parts.
The starting of the unit can be effected in 3 different
modes:
1) Start with EP6 key (Engine Control)
Put the "Local/Remote" selector on Local. Turn the
key on "ON", the EP6 display shows, only on the
machines with mounted glow plugs for 5 secs, the
symbol "UUUU", then the message "Sta" appears
the engine can be started, for then turn the key
on "start" and start the engine.
On the display the word "Sta" remains for about
20 sec then automatically disappears; the engine
must be started within 20 secs, otherwise the EP6
blocks the starting and on the display the word
"fail" appears. Turning the key on "OFF" the EP6
is reset and a new starting cycle can be fixed.
Stop:
it is COMPULSORY to disconnect the load first,
then to stop the engine turn the key on "OFF".
2) Remote starting with TCM35
Put the "Local/Remote" selector on Local. Con-
nect TCM35 to the plug on the front panel and
put the switch on "0".
Turn the key on ON in the EP6, wait for the various
signals to go out then press the button "AUTO" in
the EP6 until the led "AUTO" flashes.
Shift the switch on "I" in the TCM35 and automati-
cally the starting cycle will start. On the machines
with mounted glow plugs appears in the display
EP6 (for about 5 secs), the symbol "UUUU"; the
starting cycle includes 3 starting trials.
When the engine starts the led "AUTO" remains lit
continuously and simultaneously the red warning
light will light in the TCM35.
Stop:
it is COMPULSORY to disconnect the load first,
then shift the switch of the TCM35 on "0", the
engine will stop immediately.
3) Start with Automatic start unit (EAS)
Put the "Local/Remote" selector on Remote.
Connect the EAS to unit.
The EAS controls the starting as well as the stop
of the engine.
Follow attentively the instructions reported in the
EAS manual. In these conditions the EP6 has
the only function to measure the electric values,
hour-meter, etc.
CAUTION
!
MACHINE WITH EMERGENCY BUTTON
Pressing the button the engine will stop im-
mediately in any working condition.
Turn clockwise to reset the button.
CAUTION
!
RUNNING-IN
During the first 50 hours of operation, do not use
more than 60% of the maximum output power of
the unit and check the oil level frequently, in any
case please stick to the rules given in the engine
use manual.
NOTE
!
For safety reason the key must be kept by qualified
personel.
M
21
REV.0-02/06

Advertisement

Table of Contents
loading

This manual is also suitable for:

848209003