Daintree GE current Arize Lynk2 Installation Manual page 2

Table of Contents

Advertisement

Arize
Lynk
2
TM
RISK OF ELECTRIC SHOCK
• Turn power off before inspection, installation or removal.
• The electrical supply for each luminaire must always be
connected to the male connector.
• Not to be submerged or used in a marine environment.
RISK OF FIRE
• Follow all local codes.
RISK GROUP 1 - CAUTION / ATTENTION - RAYONNEMENT LUMINEUX GROUPE 1
RISK GROUP 2 - CAUTION / ATTENTION - RAYONNEMENT LUMINEUX GROUPE 2*
Possibly hazardous optical radiation emitted from this product. Do not stare at operating lamp. May be harmful to the eyes.
Le rayonnement lumineux émis par ce produit est potentiellement dangereux. Ne pas regarder la lumière émise directement car elle
pourrait occasionner des dommages aux yeux.
*See table below for risk groups by model.
These photobiological safety markings are based on testing of
the light output characteristic of a single horticultural luminaire.
Increased exposure risk to facility personnel may be present
depending upon the number of horticultural luminaires and their
placement and/or positioning within the plant growth facility.
It is the responsibility of the plant growth facility to address
these risks at the facility level and to ensure that people entering
the plant growth areas while the lights are on, are aware of these
risks and that appropriate safeguards are in place.
Suitable for operation in an ambient temperature
between 32°F (0°C) and 104°F (40°C).
40°C
A mechanical ventilation or cooling system is required to
maintain the temperature within the growing space below
104°F (40°C) when the light module is in operation.
0°C
Opération compatible avec un environnement à temperature
ambiante controlée entre 32°F (0°C) et 104°F (40°C).
l'utilisation d'un système de contrôle de la température sera
nécessaire pour garder la serre sous les 104°F (40°C) lorsque
le luminaire est en function.
Please contact support at arize.support@gecurrent.com with regard to applications other than horizontal. In these applications, luminaires should not be
directly interconnected and the male connector (power input) should be in the upward orientation with the female end facing down.
Electrical products must not be thrown out with domestic
waste. They must be taken to a communal collecting point
for environmentally friendly disposal in accordance with
local regulations. Contact your local authorities or stockist
for advice on recycling. The packaging material is recyclable.
Dispose of the packaging in an environmentally friendly
manner and make it available for the recyclable material
collection-service.
Manufacturer:
Current Lighting Solutions LLC, 1975 Noble Road, Cleveland, Ohio 44112 USA
Importer:
UK: Current Lighting Limited, 3rd Floor, 1 Ashley Road, Altrincham, UK, WA14 2DT
EU: Current Netherlands B.V., Programmeurstraat 6, 1033MT Amsterdam, Netherlands
WARNING / AVERTISSEMENT
RISQUES DE DÉCHARGES ÉLECTRIQUES
• Coupez l'alimentation avant l'inspection, l'installation ou le déplacement.
• L'alimentation électrique pour chacun des luminaires doit toujours
être branché du côté mâle de la prise.
• Ne pas submerger ou installer dans un environnement marin.
RISQUES D'INCENDIE
• Respectez tous les codes locaux.
Part Number
GEHL48HPPR3
GEHL48HPPB3
GEHL48HPKR3
GEHL48HPPF3
GEHL48HPKB3
GEHL48HPKF3
GEHL48HBRI3
GEHL48HBRV3
GEHL48HPPV3
GEHL96HPPR3
GEHL96HPPB3
GEHL96HPKR3
GEHL96HPKB3
GEHL96HPPV3
Conforms to the following standards:
2
Installation Guide
IEC 62471
UL Only
Risk Group
Risk Group
RG2 (Lb,Eb)
RG1
RG2 (Lb)
RG2
RG1
RG1
RG2 (Eb)
RG2
RG1
RG2
RG1
RG1
RG1
RG2
RG1
RG2
RG2 (Eb)
RG2
RG0
RG2
RG2 (Eb, Lb)
RG2
RG0
RG2
RG1
RG2
RG2 (Eb, Lr)
RG2
IP66 rated
IEC 62778
CE/UKCA Only
Min viewing
distance (mm)
N/A
447
N/A
352
390
N/A
359
420
530
325
432
257
390
482
Visit LED.com