Download Print this page
Daintree GE current Lumination RC Series Installation Manual

Daintree GE current Lumination RC Series Installation Manual

Led luminaire

Advertisement

Quick Links

Lumination
RC/LRC/RX/LRX Series - New Construction Installation
BEFORE YOU BEGIN
Read these instructions completely and carefully.
RISK OF ELECTRIC SHOCK
• Turn power off before inspection, installation or removal.
• Properly ground electrical enclosure.
RISK OF FIRE
• Follow all NEC and local codes.
• Use only UL approved wire for input/output connections.
Minimum size 18 AWG (0.75mm2).
• Do not install insulation within 3 inches (76 mm) of luminaire top.
Save These Instructions
Use only in the manner intended by the manufacturer.
If you have any questions, contact the manufacturer.
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) This device may not cause
harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
CAN ICES-005(A)/NMB-005(A)
Note: This equipment has been tested and found to comply with the
limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with
the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area
is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
LED Luminaire
®
WARNING / AVERTISSEMENT
RISQUES DE DÉCHARGES ÉLECTRIQUES
• Coupez l'alimentation avant d'inspecter, installer ou déplacer le luminaire.
• Assurez-vous de correctement mettre à la terre le boîtier d'alimentation électrique.
RISQUES D'INCENDIE
• Respectez tous les codes NEC et codes locaux.
• N'utilisez que des fils approuvés par UL pour les entrées/sorties de connexion.
Taille minimum 18 AWG (0.75mm2).
• Maintenir une distance de 76 mm (3 pouces) entre le luminaire et l'isolant.
Prepare Electrical Wiring
Electrical Requirements
• The LED luminaire must be connected to the mains
supply according to its ratings on the product label.
• Class 1 wiring should be in accordance with NEC.
Grounding Instructions
• The grounding and bonding of the overall system
shall be done in accordance to local electric code of
the country where the luminire is installed.
Installation Guide
IND259 | A-1028951

Advertisement

loading

Summary of Contents for Daintree GE current Lumination RC Series

  • Page 1 Installation Guide IND259 | A-1028951 Lumination LED Luminaire ® RC/LRC/RX/LRX Series - New Construction Installation BEFORE YOU BEGIN Read these instructions completely and carefully. WARNING / AVERTISSEMENT RISK OF ELECTRIC SHOCK RISQUES DE DÉCHARGES ÉLECTRIQUES • Turn power off before inspection, installation or removal. •...
  • Page 2: Provided Components

    Lumination RC/LRC/RXLRX Series Installation Guide ® Provided Components The components have been properly packed to avoid damage during transit. Inspect the components to confirm there is no physical damage. Do not install damaged components. Option A: If no holes are present on short side, use #8-1/2” self-drilling screws Option B: If holes are present on the short side, use the screws provided with the frame.
  • Page 3 Lumination RC/LRC/RXLRX Series Installation Guide ® RC/LRC-Series Mounting (RX-Series skip to step 15. LRXR and LRXG - Series, skip to step 18. For additional information, refer to RC-series or LRC-series Installation Guides Open RC/LRC PSU box cover, disconnect AC conduit. Remove AC conduit wire from PSU box knockout hole using flat head screwdriver.
  • Page 4 Lumination RC/LRC/RXLRX Series Installation Guide ® Place PSU box onto frame next to unused Take the provided safety tether and loop one junction box and secure with U-bracket by end of the tether around the L-bracket. tightening wing nut. Place PSU box onto frame next to unused Plug together the light fixture to the driver junction box and secure with U-bracket by enclosure with the supplied quick connects and...
  • Page 5 Lumination RC/LRC/RXLRX Series Installation Guide ® Push fixture through the hole in the ceiling. This will engage the protruding arms, thus, releasing the springs. The springs will draw the fixture up into the ceiling and hold it tightly in place. RX Series Mounting Connect AC line to existing junction box.
  • Page 6 Lumination RC/LRC/RXLRX Series Installation Guide ® LRX Series Mounting Connect conduit end with input leads to existing junction box and make proper connections. Connect the black, white and green/yellow wire of the input leads to the black, white and green wires using twist-on wire connectors and close junction box.
  • Page 7 Lumination RC/LRC/RXLRX Series Installation Guide ® Note: For 10inch and 12inch adjustable lumen fixtures, the default lumen output is set to 6000lm. Push switch left to activate 5000lm and 4000lm respectively. Adjusting CCT (for compatible fixtures only) Note: The cover of the CCT switch can be used as a tool Note: for switching CCT settings more easily.
  • Page 8 Lumination RC/LRC/RXLRX Series Installation Guide ® Note: Applicable only to 10in and 12 in Fixtures Connect the two quick connectors and reas- Affix the hook of the safety tether onto the bracket of semble the connector box. the frame kit. Load springs into an upright position by twisting Once installed, LRX Gimbal downlight’s light the springs upward a.