Arize
Lynk
2
TM
METHOD 4
Replacement Instructions for Directly Interconnected Luminaires
1
Disconnect the connector on both sides of the luminaire.
Standard Clips
Unscrew the mounting clips to completely
2A
remove the luminaire.
To insert a new luminaire, see Method 2.
3
To avoid damage, do not bend or
otherwise exert excessive force on the
connector during installation.
Pull apart
Twist
12
Luminaire to
be replaced
Slim Clips
Using a screwdriver, gently pry the luminaire
2B
out of the mounting clips.
Installation Guide