Advertisement

Quick Links

Arize® Lynk
LED Lighting
System
BEFORE YOU BEGIN
Read these instructions completely and carefully.
Den danske version af installationsvejledningen
DA
og sikkerhedsoplysninger kan findes på følgende
placering: https://gecurrent.com/eu-en
Die deutsche Version der Installationsanleitung und
DE
Sicherheitsinformationen finden Sie in folgendem
Verzeic: https://gecurrent.com/eu-en
La versión española de las instrucciones de
ES
instalación y la información sobre seguridad puede
encontrarse en la siguiente ubicación: https://
gecurrent.com/eu-en
Asennusohjeiden ja turvallisuustietojen
FI
suomenkielinen versio löytyy seuraavasta paikasta:
https://gecurrent.com/eu-en
La version française des instructions d'installations
FR
et information de sécurité est disponible à l'adresse
suivante: https://gecurrent.com/eu-en
For the latest North American install guides for your product go to: https://products.gecurrent.com/horticulture/arize-lynk
For the latest European install guides for your product go to: https://gecurrent.com/eu-en
Save These Instructions
Use only in the manner intended by the manufacturer.
If you have any questions, contact the manufacturer.
The light source of this luminaire is not replaceable; when the
light source reaches its end of life the whole luminaire shall be
replaced.
The external flexible cable or cord of this luminaire can not
be replaced; if the cord is damaged, the luminaire shall be
destroyed.
Prepare Electrical Wiring
Electrical Requirements
• Acceptable for use in dry, damp and wet locations.
• Follow all National Electric Codes (NEC) and local codes.
2
A telepítési útmutató és a biztnosági információk
HU
magyar nyelvű változata az alábbi címen található:
https://gecurrent.com/eu-en
La versione italiana del manuale di installazione
IT
e sicurezza può essere reperita nella seguente
sezione: https://gecurrent.com/eu-en
Lietuvišką diegimo instrukcijos ir saugos
LT
informacijos versiją galima rasti šioje vietoje: https://
gecurrent.com/eu-en
De Nederlandse versie van de installatie-instructies
NL
en veiligheidsinformatie kan op de volgende locatie
worden gevonden: https://gecurrent.com/eu-en
Den norske versjonen av installasjonsinstruksjonene
NO
og sikkerhetsinformasjonen er tilgjengelig på:
https://gecurrent.com/eu-en
FOR UL ONLY
Polską wersję instrukcji instalacji oraz informacje
PL
dotyczące bezpieczeństwa można znaleźć w
następującej lokalizacji: https://gecurrent.com/eu-en
A versão em Português das instruções de
PT
instalação e das informações de segurança pode
ser encontrada na seguinte localização: https://
gecurrent.com/eu-en
Ni hittar den svenska versionen
SV
av installationsanvisningarna och
säkerhetsinformationen på följande plats: https://
gecurrent.com/eu-en
This device complies with Part 15 of the FCC Rules. Operation
is subject to the following two conditions: (1) This device may
not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause
undesired operation.
CAN ICES-005 (A) / NMB-005 (A)
Note: This equipment has been tested and found to comply with the
limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with
the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area
is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
Installation Guide
EN
HORT145 | A-1027542

Advertisement

Table of Contents
loading

Summary of Contents for Daintree GE current Arize Lynk2

  • Page 1 Installation Guide HORT145 | A-1027542 Arize® Lynk LED Lighting System BEFORE YOU BEGIN Read these instructions completely and carefully. Den danske version af installationsvejledningen A telepítési útmutató és a biztnosági információk Polską wersję instrukcji instalacji oraz informacje og sikkerhedsoplysninger kan findes på følgende magyar nyelvű...
  • Page 2 Arize Lynk Installation Guide WARNING / AVERTISSEMENT RISK OF ELECTRIC SHOCK RISQUES DE DÉCHARGES ÉLECTRIQUES • Turn power off before inspection, installation or removal. • Coupez l’alimentation avant l’inspection, l’installation ou le déplacement. • The electrical supply for each luminaire must always be •...
  • Page 3: Product Length

    Arize Lynk Installation Guide Product Length Mounting Surface Luminaire length Minimum spacing / Leader cable length 4 ft. 47.3” (120 cm) 0.2" (5 mm) / 23.6" (600 mm) 8 ft. 95” (240 cm) 0.2" (5 mm) / 23.6" (600 mm) Tools Required Components Required Wire stripper/cutter...
  • Page 4 Arize Lynk Installation Guide METHOD 1 Single Luminaire Installation Before starting: Luminaires must only be mounted using Current’s standard or slim mounting clips (see Components Required on page 3). Mounting instructions using Current’s standard and slim mounting clips. SNAP! Align using chalk line, laser projector or similar SNAP! Rotate and Push...
  • Page 5 Arize Lynk Installation Guide METHOD 2 Directly Interconnected Luminaires Before starting: See Multiple Bar Installation Details to ensure you won't exceed the maximum run length per leader cable. Luminaires must only be mounted using Current’s standard or slim mounting clips (see Components Required on page 3). Linear Layout NOTE: the recommended distance between two ends should be no more than 0.8"...
  • Page 6 Arize Lynk Installation Guide METHOD 2 Directly Interconnected Luminaires CLICK! Remove end cap from the female connector. Insert Use a jumper cable to connect luminaires if the the male connector to the female connector. Make distance between them is too long. sure the connector is fully engaged as indicted by hearing a click.
  • Page 7: Wiring Connections

    Arize Lynk Installation Guide METHOD 3 Wiring Connections Insert the female connector of the leader cable so that it fully engages the male connector of the first luminaire in the run as indicated by hearing a click. NOTE: the male connector can be cut off if there is no leader cable. See Multiple Bar Installation Details to not exceed maximum run length for one leader.
  • Page 8 Arize Lynk Installation Guide METHOD 3 M19 Cable Accessories Accessory Type Model Description M19 Leader Cable (NA) 93142247 GECA30A18-CC10B 10ft (3.0m) Leader with dimming 93142232 GECA30A18-BB06B 6ft (1.8m) Leader 93142234 GECA30A18-BB10B 10ft (3.0m) Leader M19 Leader Cable (EU/UK) 93142246 GECA30A18-BC06B 6ft (1.8m) Leader with dimming 93142248 GECA30A18-BC10B...
  • Page 9 Arize Lynk Installation Guide METHOD 3 M25 Cable Accessories Accessory Type Model Description M25 Leader (EU/UK) 93142254 GECA30A14-BG06B 6ft (1.8m) Leader with dimming, 15A, EU M25 Jumper (NA/EU/UK) 93142255 GECA30A14-CH02B 2ft (0.6m) Jumper with dimming 8ft (2.4m) Splitter with 1 M25 male to 5 M25 Splitter (NA/EU/UK) 93142257 GECA30A14-CJ08B...
  • Page 10 Arize Lynk Installation Guide METHOD 3 M25 Cable Accessories Installation Example B M19 Splitter *5 M19 Jumper (optional) M25 14AWG Leader Cable GEHL48Hxxx3 38@120V, 65@208V, 72@240V, 83@277V; GEHL96Hxxx3 M19 18AWG Leader Cable 19@120V, GEHL48Hxxx3 max 14@120V, 20@208V, 26@240V, 26@277V; 32@208V, 36@240V, GEHL96Hxxx3 max 7@120V, 10@208V, 13@240V, 13@277V 41@277V...
  • Page 11: Product Codes

    Arize Lynk Installation Guide Multiple Bar Installation Details Input voltage : 120VAC - 277VAC, 50/60Hz Maximum Bars Qty of Maximum Bars Electrical Loading Detail Per Interconnected run or Mounting Per M25 14AWG Leader Cable Typical Current (A) M19 18AWG Leader Cable Clips Lamp Product...
  • Page 12 Arize Lynk Installation Guide METHOD 4 Replacement Instructions for Directly Interconnected Luminaires Pull apart Luminaire to be replaced Twist Disconnect the connector on both sides of the luminaire. Standard Clips Slim Clips Unscrew the mounting clips to completely Using a screwdriver, gently pry the luminaire remove the luminaire.
  • Page 13 Arize Lynk Installation Guide Installing the Optical Lens Accessory Type Model Description Qty./box LENS 93142258 CLIP-LENS-LYNK2 Clip lens for Batten Gen 3 100pcs/box Lens Clip Lens Body The optical lens has two parts: lens clip and lens body Rotate Clip Push Press the lens clip into the luminaire enclosure.

Table of Contents