Error Messages & Trouble Codes - Cal Spas Platinum Spa La Jolla Owner's Manual

Table of Contents

Advertisement

30
Error messages
The list below shows the different error messages that can appear on the home screen�
Refer to the troubleshooting and error codes section of the TechBook for your spa pack system�
Please note that if you are in a swim spa configuration, the message may be followed by "Master" or "Slave" to designate
from which pack the error is coming�
Code
HL
FLO - L01 FLO - L02 FLO
NO FLO
HR
OH
Pr
AOH
FLC
SP in
RH NC
RH ID
SC ER
F1
F2
F3
ER1
Hr
UPL
CFLO
HIBr
HiBr
LoBr
NoBr
Comm
Supp
HP1-99
Message
High Limit circuit has tripped!
FLO condition - Check filter, pump, blockage, air lock and water level
Persistent NO FLO, all off - Check filter, pump, blockage, air lock and water level
A hardware error was detected (Relay stuck)
Spa temperature is too high
Temp probes or detection circuit are defective
Elevated internal temperature
The pressure switch is closed
Input voltage issue
Comm� error between in�xm2 - in�therm
in�xm2 and in�therm incompatible
Error detected during the learning mode
in�xm2 Fuse # 1 is blown
in�xm2 Fuse # 2 is blown
in�xm2 Fuse # 3 is blown
SwimSpa config� : slave unit is missing
Hardware error was detected (Thermal fuse)
The spa pack does not have valid software�
Please insert valid in�stick to reprogram spa pack�
No Flow condition
Add fresh water to the spa
Add fresh water to the spa
Add BromiCharge to spa water
Add BromiCharge to spa water
Verify cable connections
Connect power cord to 240 V source
Heat Pump error! Service Code 1-99, Contact Dealer
+