MAINTENANCE
CLEANING THE GENERATOR
Keep the generator clean to prevent improper operation or machine damage from dirt and debris. Inspect all ventila-
tion openings on the generator. These openings must be kept clean and unobstructed.
If the generator becomes dirty, use a damp cloth to wipe exterior surfaces. Use a soft bristle brush to loosen dirt and
oil and use a vacuum to pick up loose dirt. Use low pressure air (not to exceed 25 PSI) to blow away dirt.
WARNING! Never clean the generator when it is running! Never clean with a bucket of water or a hose. Water
can get inside the working parts of the generator and cause corrosion or a short circuit.
CHECKING / ADDING OIL
Check the oil level before each use and every 8 hours of operation (refer to Table 4).
The oil capacity of the generator engine is 30.4 fl. oz. (0.90 L). Add oil when the oil level is low. For proper type and
weight of oil refer to "add oil" portion of the "Generator Preparation" section. This is a critical step for proper engine
starting. The generator is equipped with a with low-oil shut down to protect it from running without oil.
To check the oil level and add oil:
1. Make sure the generator is on a level surface. Do not tilt the generator, as oil will flow into engine areas and cause
damage. Keep generator level!
2. Remove the dipstick and wipe it with a clean rag.
Fig. 18
3. Insert the dipstick into the oil fill opening without screwing
in. Remove the dipstick to check the oil mark (Fig. 18). Add oil if
the oil mark covers less than one half of the dipstick.
Upper Limit
4. Using a funnel or appropriate dispenser, slowly add more oil.
Repeat the step above until the oil mark reaches the top of the
dipstick. Do not over fill.
5. Reinstall dipstick and wipe clean any spilled oil with a rag.
Lower Limit