Use Of Extension Cords - OCEANAIRE OWC QC Series Engineering, Installation And Service Manual

Deluxe portable water-cooled cooler with quick connect
Table of Contents

Advertisement

CAUTION
FOR MODEL OWC1811QC AN EXTENSION CORD CAN BE USED PROVIDED IT IS
RATED AT LEAST 15 AMPS @ 115 VOLTS WITH GROUNDING-TYPE ATTACHMENT
PLUG AND GROUNDING TYPE CONNECTOR (LOAD FITTING)
FOR MODELS OWC2412QC and OWC3612QC AN EXTENSION CORD CAN BE USED
PROVIDED IT IS RATED AT LEAST 20 AMPS @ 250 VOLTS WITH GROUNDING-TYPE
ATTACHMENT PLUG AND GROUNDING TYPE CONNECTOR (LOAD
FITTING)
FOR MODEL OWC6012QC AN EXTENSION CORD CAN BE USED PROVIDED IT IS
RATED AT LEAST 30 AMPS @ 250 VOLTS WITH GROUNDING-TYPE ATTACHMENT
PLUG AND GROUNDING TYPE CONNECTOR (LOAD FITTING)
FOR MODEL OWC3632QC AN EXTENSION CORD CAN BE USED PROVIDED IT IS
RATED AT LEAST 20 AMPS @ 250 VOLTS, 3 PHASE
FOR MODEL OWC6032QC AN EXTENSION CORD CAN BE USED PROVIDED IT IS
RATED AT LEAST 30 AMPS @ 250 VOLTS, 3 PHASE
FOR MODELS OWC3634QC AND OWC6034QC AN EXTENSION CORD CAN BE USED
PROVIDED IT IS RATED AT LEAST 20 AMPS @ 600 VOLTS, 3 PHASE
SPECIAL NOTICE—THREE PHASE OPERATION
Models OWC3632QC, OWC3634QC, OWC6032QC and OWC6034QC
All three-phase OWC-QC models are equipped with a three-phase monitor for
added compressor protection. The phase monitor, located in the control box, has
multi-color LED that reports status. The monitor protects the compressor from
reverse operation, phase loss and low voltage situations. Further description of the
three-phase monitor is located in the electrical section of the manual.
NOTICE
- DO NOT OPERATE ANY THREE-PHASE UNIT WHILE
BY-PASSING THE MONITOR.

USE OF EXTENSION CORDS

THIS WILL VOID THE WARRANTY.