Parker AFL Series Operation And Maintenance Manual

Parker AFL Series Operation And Maintenance Manual

Air driven, high pressure liquid pump

Advertisement

Quick Links

AFL Series Pump
Operation and Maintenance Manual
Air Driven, High Pressure Liquid Pump
Catalog: 02-9309ME
March 2013

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AFL Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Parker AFL Series

  • Page 1 AFL Series Pump Operation and Maintenance Manual Air Driven, High Pressure Liquid Pump Catalog: 02-9309ME March 2013...
  • Page 2: Table Of Contents

    Pump Functionality ....................6 10.0 Suggested Maintenance ..................6 11.0 Trouble Shooting-Pneumatic Section ..............7 12.0 Trouble Shooting-High Pressure Liquid Section ........... 8 13.0 Service ........................8 Parker Autoclave Engineers Instrumentation Products Division Erie, PA USA www.autoclave.com | Cat. 02-9309ME...
  • Page 3: Introduction

    150 psi (10 bar). Au- shipping carton should be opened and the contents carefully toclave Engineers AFL Series pumps are used for pumping oil, examined upon receipt from the carrier. Make sure there is no water and oil/water mixtures.
  • Page 4: Compressed Air Supply

    All AFL series pumps have a high pressure liquid outlet port located on the side of the pump head. The suction inlet port on all AFL series pumps is positioned at the bottom of the head. Section 6.1 Compressed Air Supply...
  • Page 5: Pump Start-Up

    Use an air pressure regulator to assure maximum air drive pressure listed on the pump label is not Parker Autoclave Engineers pumps discussed in this manual are exceeded. An air pressure regulator must also be used to used for pumping oil, water and oil/water mixtures. Special seals assure the pump will not exceed maximum liquid output are also available for chemical service.
  • Page 6: Pump Functionality

    • Replace check valve components • Replace high pressure hydraulic seals 7) Piston continues to move down until it hits the pilot valve assembly in the bottom end cap. Parker Autoclave Engineers Instrumentation Products Division Erie, PA USA www.autoclave.com | Cat. 02-9309ME...
  • Page 7: Trouble Shooting-Pneumatic Section

    Seal between air piston and liquid plunger is leaking. Solution: a) Replace and lubricate spool valve o-rings. b) Replace and lubricate sleeve o-rings. c) Replace and lubricate air piston o-ring(s). Parker Autoclave Engineers Instrumentation Products Division Erie, PA USA www.autoclave.com | Cat. 02-9309ME...
  • Page 8: Trouble Shooting-High Pressure Liquid Section

    FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical expertise. It is important that you analyze all aspects of your application and review the information concerning the product or system in the current product catalog.

This manual is also suitable for:

02-9309me

Table of Contents