INSTRUCTION MANUAL
MOD. B150/10
TRANSLATION OF THE ORIGINAL INSTRUCTIONS
GENTILIN SRL Via delle Tezze, 20/22 | 36070 Trissino (VI) ITALY
Tel. +39 0445 962000 | info@gentilincompressors.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 812404001 and is the answer not in the manual?

Questions and answers

Summary of Contents for GENTILIN 812404001

  • Page 1 INSTRUCTION MANUAL MOD. B150/10 TRANSLATION OF THE ORIGINAL INSTRUCTIONS GENTILIN SRL Via delle Tezze, 20/22 | 36070 Trissino (VI) ITALY Tel. +39 0445 962000 | info@gentilincompressors.com...
  • Page 3: Table Of Contents

    Rev. 09_2023 41032902 INDEX 1 PARTS LIST ............................... 4 2 TECHNICAL SPECIFICATIONS ......................... 5 3 CE DECLARATION OF CONFORMITY ..................... 5 4 CE LABEL ..............................6 5 IMPORTANCE OF THE MANUAL ......................6 6 RECIPIENTS .............................. 6 7 STATUS “APPLIANCE OFF” ........................7 8 WARRANTY ..............................
  • Page 4: Parts List

    41032902 Rev. 09_2023 1. PARTS LIST Non-return valve Air filter Twin cylinder pump system Safety valve (set to 10.5 bar) Condensate pump Tank pressure gauge Tank outlet gauge Pressure switch Air tank ON (I) – OFF (O) switch Electric motor Handle.
  • Page 5: Technical Specifications

    365 × 515 × 365 mm Motor rotation direction (both ways) 3. CE DECLARATION OF CONFORMITY Gentilin S.r.l. - Via delle Tezze, 20/22 36070 Trissino (VI) - Italy - VAT N.: 01262520248 Declares that the following machine: COMPRESSOR B150/10 MACHINE: Air volumetric compressor...
  • Page 6: Ce Label

    2020 10 BAR 32Kg GENTILIN S.R.L. - Via delle Tezze 20/22 - 36070 Trissino (VI) Italy - VAT/P.Iva 01262520248 5. IMPORTANCE OF THE MANUAL BEFORE USING THE APPLIANCE IN QUESTION, AUTHORISED USERS MUST READ AND UNDERSTAND THE PRESENT INSTRUCTION MANUAL IN ITS ENTIRETY.
  • Page 7: Status "Appliance Off

    Rev. 09_2023 41032902 AUTHORISED OPERATORS MUST ONLY CARRY OUT OPERATIONS FOR WHICH THEY ARE QUALIFIED. BEFORE CARRYING OUT ANY OPERATIONS, AUTHORISED OPERATORS MUST POSSESS ADEQUATE PSHY- CHO-PHYSICAL CAPABILITES IN ORDER TO ALWAYS ENSURE SAFETY. ASSIGNED OPERATOR: An operator over the age of 18 (private user or employee) and, who, in com- pliance with current legislation on health and safety in the work place in force within the country of usage, is capable of exclusively activating, using and deactivating the appliance whilst completely complying with the instructions presently provided, whilst using the dedicated personal safety device items.
  • Page 8: Warranty

    41032902 Rev. 09_2023 8. WARRANTY 1) WARRANTY DECLARATION: the Manufacturer guarantees the Acquirer, the replacement, repair and intervention relative to all appliances, where the aforementioned display conformity defects which comprise correct usage and operation, only where such defects are owing to the fault of the Manufacturer. The Manufacturer reserves the right to adopt the best solution in order to restore appliance conformity within a reasonable amount of time.
  • Page 9: Incorrect Use

    Rev. 09_2023 41032902 INTENDED USE Compressing air (no oil) to be used with suitable pneumatic utensils according to current legislation in force (E.g. blowing, pumping, washing, veneering and sandblasting, etc.). OPERATORS AUTHORISED USE An authorised operator with professional, technical skills as described in Paragraph 6. 11.
  • Page 10: Transportation And Movement Of The Appliance

    41032902 Rev. 09_2023 12. TRANSPORTATION AND MOVEMENT OF THE APPLIANCE The appliance may be manually transported by two qualified operators, gripping it by the foot (A) and the handle (B). TRANSPORTATION OF THE APPLIANCE MUST BE CARRIED OUT BY TWO QUALIFIED OPERATORS IN COM- PLIANCE WITH REGULATIOSNS OVERSEEING “MANUAL MOVEMENT OF LOADS”...
  • Page 11: Electrical Connection

    Rev. 09_2023 41032902 17. ELECTRICAL CONNECTION The machine can be connected to the mains electrical supply by plugging the power cable into the special socket. THE POWER SUPPLY NETWORK TO WHICH THE APPLIANCE IS CONNECTED MUST CONFORM TO THE LE- GISLATION CURRENTLY IN FORCE IN THE COUNTRY OF USAGE, CONFORM TO THE TECHNICAL SPECIFICA- TIONS PROVIDED IN PARAGRAPH 2 AND BE EQUIPPED WITH A SUITABLE “PLANT EARTHING”...
  • Page 12: Safety Devices Adopted

    41032902 Rev. 09_2023 19. SAFETY DEVICES ADOPTED SAFETY VALVE (4): a certified safety valve (set to 10.5 bar), installed to the pneumatic system, under the pressure switch. It tackles over-pressure in the instance where, owing to anomalies, the pressure switch does not function. Safety valve intervention ensures the operator switches off the appliance and requests the support of maintenance persons.
  • Page 13: Safety Signs

    Rev. 09_2023 41032902 20. SAFETY SIGNS Safety signs used take the formof a sticky label, applied to the appliance exterior. Sign definitions: Warning – electrical power. Warning – automatic start-up. Warning – high temperature. Instructions must be read. Power must be disconnected. Protect your hearing.
  • Page 14: Residual Risks

    41032902 Rev. 09_2023 22. RESIDUAL RISKS Although the Manufacturer has adopted all technical construction solutions in order to make the appliance as safe as possible, authorised operators please be aware that residual risks remain. RESIDUAL RISK Danger of burns upon accidental contact with the twin cylinder pump system and the electric motor.
  • Page 15: Pre-Start-Up Checks

    Rev. 09_2023 41032902 25. PRE-START-UP CHECKS BEFORE STARTING UP THE APPLIANCE, AUTHORISED OPERATORS MUST CARRY OUT THE FOLLOWING CHECKS. • Ensure that no unauthorised persons are in close proximity of the appliance. • Ensure that safety devices are not damaged and that they are correctly installed and operational (see Paragraph 19). •...
  • Page 16: Appliance Deactivation

    41032902 Rev. 09_2023 1) Connect the appliance to the power supply (1) by plugging it in. 2) Switch on the appliance using the “ON-OFF” switch (3) ensuring it is in the “ON (I)” position (the appliance is operational until it reaches a maximum operating pressure of 10 bar, after which, it switches off automatically. 3) Regulate the outlet pressure using the relevant regulator (4) according to the utensil used and type of work.
  • Page 17: Reset Intervention - Thermal Restore

    Rev. 09_2023 41032902 28. RESET INTERVENTION – THERMAL RESTORE In the instance where current overload and/or a short circuit of the appliance electrical system is noted, the thermal restore intervenes, disabling the electric motor. To carry out the reset intervention, proceed as follows: 1) Turn the “ON-OFF”...
  • Page 18 41032902 Rev. 09_2023 STANDARD MAINTENANCE TABLE FREQUENCY INTERVENTION AREA INTERVENTION TYPE ONCE A DAY Safety devices. Ensure they are intact, correctly installed and functioning. Electrical cable and plug. Visual check of usage status. Tank. Upon termination of each work cycle, rest the appliance on the ground and drain the tank condensate pump opening the condensate pump (A).
  • Page 19: Extraordinary Maintenance

    Rev. 09_2023 41032902 32. EXTRAORDINARY MAINTENANCE All activities carried out to ensure use and operation of the appliance, via various intervention types (regulation, valve checks, cleaning of air filters, etc.) executed by the Manufacturer’s technicians according to preestablished time intervals and in the instance of faults or wear and tear.
  • Page 20 41032902 Rev. 09_2023 ABNORMALITIES CAUSE SOLUTION The appliance restarts Leakages from the air pipe, • Check that the pneumatic system is not damaged. numerous times even utensil or pneumatic sy- • Check that the air pipe and utensils are intact as well as the without a utensil.
  • Page 21 Rev. 09_2023 41032902 SINGLE TABLE FOR PACKAGING DISPOSAL D.LGS. 116/2020 (ITA) - UE 2018/852 D.Lgs. 116/2020 (ITA) - UE 2018/852 Scatola (cartone Scatola (cartone Busta / Film Vite / Staffa / Pallet Foglio Reggia Reggia Protezione ondulato) pressato) estensibile Graffa LEGNO CARTA CARTA...