Jumper JPD-FR202 User Manual
Hide thumbs Also See for JPD-FR202:

Advertisement

Screen Termometro Infrarossi
Infrared Thermometer
User Manual
REF: 971664331
CATALOGUE NR: JPD-FR202
PRODUCT INFORMATIO
Product Name: Infrared Thermometer
Model: JPD-FR202 Software version:1.0.0
Manufacturer: Shenzhen Jumper Medical Equipment Co., Ltd
Address: D Building, No. 71, Xintian Road, Fuyong Street, Baoan, Shenzhen, Guangdong,
China,518103
COPYRIGHT
Copyright © Jumper Medical. All rights reserved.
STATEMENT
Shenzhen Jumper Medical Equipment Co., Ltd. owns and reserves all of the rights
comprised in the copyright of this document. No part of this document may be changed,
excerpted, copied, reproduced, or imitated in any form or by any means without the prior
consent of Shenzhen Jumper Medical Equipment Co., Ltd.
All statements, information, and recommendations in this document are provided "AS IS"
without warranties, guarantees or representations of any kind, either express or implied. The
information in this document is subject to change without notice. Shenzhen Jumper Medical
Equipment Co., Ltd. reserves the right of final interpretation of this document.
INTRODUCTION
Thank you for purchasing this Infrared Thermometer. Please read the Instruction Manual
carefully to make sure safe and proper use of this thermometer.
Please read and fully understand the Safety Precautions before use.
Keep the Instruction Manual with this thermometer for future reference.
UNPACKING CHECK
Please open the package carefully before use, check whether all accessories are available
or not and whether any component is damaged during transportation, and perform
installation and operation following this user manual. In case of any damage or operation
problem, please contact the dealer or contact Jumper directly. You will need the following
information when making your claim: device model, serial number, purchase date, and your
contact information and address.
PACKAGE CONTENTS
No.
Name
1
Infrared Thermometer
2
Pouch
2
Battery (AAA)
2
Instruction Manual
Read the following precautions carefully before using the thermometer.
Take care of the temperature probe lens, which is fragile.
No service /maintenance while the equipment is in use.
Dispose used batteries with care. To protect the environment, you are
English
recommended to send the used batteries to a designated collection point.
English
The thermometer doesn't need recalibration.
- Make sure that the thermometer is not exposed to lint, dust,
light (including sunlight), etc.
- Please note the effects of degraded sensors that can degrade performance or
cause other problems
- Make sure that the thermometer is not exposed to pets, pests.
If the thermometer is soiled or its infrared optical components
is damaged, please stop using it.
The lay operator or lay responsible organization should contact the manufacturer
or manufacturer's representative on the following issues: -assistance in setting
up, using, or maintaining the me equipment or me system when needed, or to
report unexpected operation or events.
The IR thermometer is identified as intended for consumer use.
The patient is an intended operator.
The effect that the following actions could be unsafe as applicable: use of
accessories, detachable parts, and materials not described in the instructions for
use or modification of the equipment.
The hazards that can result from unauthorized modification of the me equipment.
The manufacture can provide the circuit diagram, component part list, description
and calibration instructions to assist service personal for parts repair.
Do not subject the thermometer to vibration or impact.
Do not take body temperature readings within 20 minutes after you do physical
exercises or get excited.
Do not use the thermometer for continuous temperature monitoring purposes.
Do not use the thermometer for purposes that are not specified in this User
Manual. Follow the instructions in the "Measurement Process" chapter and
carefully operate the thermometer when measuring children's temperature.
Do not immerse the thermometer into water or other liquid. Clean and disinfect the
thermometer as described in the "Cleaning and Disinfection" chapter.
Do not touch the tip of the temperature probe, on which a precise temperature
Quantity
sensor resides.
1
Keep the temperature probe clean to make sure accurate readings.
1
The ambient temperature must not be extremely high or low. To make sure
2
1
accurate readings, keep the thermometer under room temperature for more than
30 minutes before use.
Do not use the thermometer under an ambient temperature higher than 40°C
(104°F) or lower than 10°C (50°F), which is beyond the operating temperature
range of the thermometer.
SAFETY PRECAUTIONS
Attention
Risk of pollution! The user is recommended to send the overdue thermometer
to local garbage disposal site or send it back to us.
2 AAA batteries of 1.5V are the only replaceable accessories of the thermometer.
Please do not use the batteries of other voltages or specifications.
WARNING
Warning
The thermometer is not intended to diagnose or treat any health problem or
disease. The measurement results are for reference only.
It is dangerous to make a self-diagnosis or self-treatment based on the obtained
measurement results. For such purposes, please consult a physician or other
medical professionals.
Do not charge an alkaline dry-cell battery or throw it in fire. Otherwise, the battery
may explode.
Do not disassemble the thermometer or attempt to repair it. Otherwise, the
thermometer may be damaged permanently.
Do not take temperature measurements on body parts other than forehead.
Otherwise, the temperature readings may be inaccurate.
During measurement, do not use a mobile phone or any other device that may
cause electromagnetic interference.
Do not use the thermometer in an environment where flammable anesthetic
mixture with air or with oxygen, or nitrous oxide is available.
Please keep the thermometer out of the reach of children.
The result may be inaccurate if you use the overdue thermometer.
SYMBOLS
Symbol
Description
Type BF applied part.
Attention must be paid.
The action is prohibited.
Information about the manufacturer.
Date of manufacture.
Consult the instructions for use.
This product complies with the MDD93/42/EEC requirements.
Waste electrical materials should be sent to a dedicated
collection point for recycling.Must contact its local authorities to
determine the proper method of disposal of potentially bio
hazardous parts and ACCESSORIES.
IP22
Degree of protection against the Ingress of water.
A personal injury or damage to the thermometer may occur if the
Warning
thermometer is not used correctly.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the JPD-FR202 and is the answer not in the manual?

Questions and answers

Summary of Contents for Jumper JPD-FR202

  • Page 1 Information about the manufacturer. Manual. Follow the instructions in the "Measurement Process" chapter and problem, please contact the dealer or contact Jumper directly. You will need the following information when making your claim: device model, serial number, purchase date, and your carefully operate the thermometer when measuring children's temperature.
  • Page 2 Backlight Instructions” section Infrared Thermometer JPD-FR202 measures the human body or an object temperature and the forehead must be 1- based on the infrared energy emitted by the forehead or an object (such as milk and water).
  • Page 3 Operating Instructions/ Operating Instructions/ Operating Instructions/ Screen Display Description Screen Display Description Screen Display Description Displayed State Displayed State Displayed State In a power-on state, press the “Mode button”, the thermometer enters the Object mode. Point the IR sensor to the In a power-on state, press center of the object, then See the table in the “Sounds and...
  • Page 4: Replacing Batteries

    convection between the thermometer and the target. For example, winds from a Operating Instructions/ Screen Display Description Displayed State fan, an air-conditioner, or a heater. (2) Do not hold the thermometer for a long time, because it is sensitive to the ambient An error occurs when data temperature.
  • Page 5: Troubleshooting

    Product Name Infrared Thermometer IEC 61000-4-2 ±15 kV air ■ The thermometer is impermanent installed device. Product Model JPD-FR202 Electrical fast ± 2 kV for power supply lines Not applicable transient/burst ± 1 kV for input/output lines Power Supply Mode...
  • Page 6: Warranty And After-Sale Service

    Table 4 declaration - IMMUNITY to proximity fields from RF wireless communications equipment Immuni IEC60601 test level Compliance Shenzhen Jumper Medical Equipment Co., Ltd. ty test level Address: D Building, No. 71, Xintian Road, Fuyong Street, Baoan, Shenzhen,Guangdong,China Test Modulatio...

Table of Contents