INSTALLATION
Installation
Flow rate
Preparing the power cable on unfinished walls, for connection
from below
> Ensure that the flow rate for switching on the appliance is
achieved.
> Increase the water line pressure if the required flow rate
is not achieved when the draw- off valve is fully open. If
the flow rate is still not achieved, remove the flow limiter
(see chapter " Installation / Installation / Removing the flow
limiter").
10. Installation
Factory settings
DHB-E
DHB-E
DHB-E
DHB-E
11/13
18 LCD 18/21/24
27 LCD
LCD
25A
LCD
Internal anti- scalding
° C
60
60
60
60
protection
Connected load
kW
13.5
18
21
27
Connected load options
x
-
x
Standard installation
Electrical connection from
below on unfinished walls
DHB-E
DHB-E
DHB-E
DHB-E
11/13
18 LCD 18/21/24
27 LCD
LCD
25A
LCD
X
x
x
x
Water connection
on
unfinished walls
x
x
x
x
For further installation options, see chapter "Alternative instal-
lation methods".
10.1
Standard installation
Opening the appliance
> Seal and insert the twin connectors.
> Open the appliance by holding the fascia at the side and pull-
ing forwards away from the appliance cover. Undo the screw.
Pivot open the appliance cover.
> Remove the back panel by pressing the two locking tabs and
pulling the lower section of the back panel forwards.
1 Cable entry installation aid
> Prepare the power cable.
Fitting the wall mounting bracket
> Mark out the holes for drilling using the installation tem-
plate. If the app iance is to be installed on finished walls, also
mark out the fix ng hole in the lower section of the template.
> Drill the holes and secure the wall mounting bracket at 2
points using suitable fixing materials ( screws and rawl plugs
are not part of the standard delivery).
> Fit the wall mounting bracket.
Installing the twin connectors
O
Material losses
Carry out all water connection and installation work in
accordance with regulations.