FIRE ALARM

Input terminal FA1 and FA2
When the signal from the fire alarm system is
the unit turns off and does not operate until the unit has been RESET.
● Connecting the fire alarm wire from fire alarm system
1. Remove the 'Cap' on the 'Fire Alarm Cover'.
2. Use recommended fire alarm wire size from 16 AWG to 26 AWG for a solid wire,
or 16 AWG to 22 AWG for a stranded wire with ring terminal for #5 stud size.
3. Connect fire alarm to terminal FA1 and FA2.
,
detected
FIRE ALARM SIGNAL INPUT
FA1
CLOSED
FA2
FA1
FA2
Input
Fire alarm
Signal
Terminal
NORMAL CONDITION
FA1
OPEN
FA2
FIRE ALARM SYSTEM
ALARM
Wire
15
Close
Remove
Cover
Cap
15