Wiring Precautions
WARNING
BEFORE PERFORMING ANY ELECTRICAL WORK, READ THESE REGULATIONS.
All wiring must comply with local and
national electrical codes, regulations
and must be installed by a licensed
electrician.
All electrical connections must be made
according to the Electrical Connection
Diagramlocated on the panels of the
indoor and outdoor units.
If there is a serious safety issue with the
power supply, stop work immediately.
Explain your reasoning to the client, and
refuse to install the unit until the safety
issue is properly resolved.
Power voltage should be within 90-110%
of rated voltage. Insu cient power
supply can cause malfunction, electrical
shock, or fire.
If connecting power to fixed wiring, a
switch or circult breaker that dis-
connects all poles and has a contact
separation of at least 1/8in (3mm) must
be incorporated in the fixed wiring. The
qualified technician must use an
approved circuit breaker or switch.
Only connect the unit to an individual
branch circuit. Do not connect another
appliance to that outlet.
Make sure to properly ground the air
conditioner.
Every wire must be firmly connected.
Loose wiring can cause the terminal to
overheat, resulting in product
malfunction and possible fire.
If connecting power to fixed wiring,
install a surge protector and main power
switch with a capacity of 1.5 times the
maximum current of the unit.
Do not let wires touch or rest
against refrigerant tubing, the
compressor, or any moving parts
within the unit.
If the unit has an auxiliary electric
heater, it must be installed at
least 1 meter (40in) away from
any combustible materials.
To avoid getting an electric
shock, never touch the electrical
components soon after the power
supply has been turned o . After
turning o the power, always
wait 10 minutes or more before
you touch the electrical
components.
Make sure that you do not cross
your electrical wiring with your
signal wiring. This may cause
distortion, interference.
The unit must be connected to
the main outlet. Normally, the
power supply must have a
impedance of 32 ohms.
No other equipment should be
connected to the same power
circuit.
Connect the outdoor wires before
connecting the indoor wires.
WARNING
BEFORE PERFORMING ANY
ELECTRICAL OR WIRING
WORK, TURN OFF THE MAIN
POWER TO THE SYSTEM.