Preparations for Installation
Refer to the following diagram to ensure
proper distance from walls and ceiling:
50cm
(19.7in)
or more
200cm
(78.7in)
or more
Unfastening the operation panel and
detaching the filter
1. Open the packaging and take out the
indoor unit. Remove the protective tape
and any components.
2.
Remove all of the accessories.
3.
Check that all of the accessories match
those found on the "Accessories" as
shown on the previous page.
4.
Take out the PM2.5 filter and install it.
30cm (11.8in)
or more
5cm
(2in)
or more
50cm
(19.7in)
or more
Fastening the indoor unit (to prevent
it from falling down)
Measure the position of the holes for
1.
installation.
Insert the M8 bolts into the unit while it is on
2.
the floor (the amount of bolts used depends
on the number of holes on the unit's chassis).
Lift up the indoor unit so that the installation
3.
holes cover the bolts, then fasten the nuts
onto the bolts and tighten them.
CAUTION
If further support is needed to prevent
the unit from falling down, a protective
wedge can be installed. The installation
procedure for this wedge is as follows:
• Take out the protective wedge and
measure the correct size.
• Use the self-tapping screws to
fasten the protective wedge to the
top cover of the indoor unit.
• Fasten the other end of the wedge
tightly to the wall using the
self-tapping screws.