DAD'S CORNER SHED - 2.4m x 2.4m
All dimensions are approximate and subject to the limitations of the materials used and the methods of manufacture
Manufacturer:
Dunster House Ltd.
Caxton Road
Bedford
Bedfordshire
England
MK41 0LF
(8ft x 8ft)
H4-2424DCSH
Installation Manual
Please read this installation manual carefully
before proceeding with the construction of your shed.
Important!
Unique Shed Reference Number
_____________________________
V1
Customer Service:
cs@dunsterhouse.co.uk
www.dunsterhouse.co.uk

Advertisement

loading
Need help?

Need help?

Do you have a question about the DAD'S CORNER SHED H4-2424DCSH and is the answer not in the manual?

Questions and answers

Summary of Contents for Dunster House DAD'S CORNER SHED H4-2424DCSH

  • Page 1 Please read this installation manual carefully before proceeding with the construction of your shed. Important! All dimensions are approximate and subject to the limitations of the materials used and the methods of manufacture Manufacturer: Dunster House Ltd. Caxton Road Bedford Unique Shed Reference Number Bedfordshire...
  • Page 2 In the unlikely event that you need to contact us, please do so in writing to: Email: cs@dunsterhouse.co.uk Post: FAO Customer Services, Dunster House Ltd - Factory 1, Caxton Road, Bedford, MK41 0LF Our Customer Services department is open 9:00 - 17:00, Monday to Friday. Please include your Sales Order number starting with SO or your postcode so we can locate your order.
  • Page 3 Should you discover a rip or tear, the best course of action is to replace it immediately. At Dunster House, we sell high-grade mineral felt. More information on replacing the shed's roof material can be found here:...
  • Page 4 Pack Contents PANEL ED - 1520x343 PANEL CM - A - 1140x2044 PANEL CM - B - 1140x1972 PANEL CL - A - 1140x2044 PANEL BE - 1205x2117 PANEL CL - B - 1140x1972 PANEL BF - 1205x2117 PANEL FC - 690x1770 PANEL FD - 725x1770 MFP - 2280x1060x10 ST-PT15151860 - L = 1860mm...
  • Page 5 Pack Contents ST-PT3570100 - L = 100mm ST-PT2535815 - L = 815mm ST-PT16701220 - L = 1220mm ST-PT35352220.85.85 - L = 2220mm ST-PT16701370 - L = 1370mm ST-PT16701600 - L = 1600mm ST-PT35701710.85.85.A - L = 1710mm ST-PT20231500 - L = 1500mm ST-PT35701770.85.85.
  • Page 6 Pack Contents FIXINGS COMPONENT 70mm SCREW 50mm SCREW 35mm SCREW COACH BOLT M6x60 WASHER M6 NUT M6 30mm PIN NAIL 10mm CLOUT NAIL SHOOT BOLT FELT Please note: You many have some extra fixings left over as we provide extra. Page 6...
  • Page 7 Panels Layout PANEL CM - B PANEL CL - B PANEL CM - A PANEL CL - A PANEL BE PANEL BF FRONT PANEL ED Page 7...
  • Page 8 Assembly Steps Pre-drill parts before fixing with screws STEP 1: PANELS Items: 10x 50mm SCREWS Principle of connecting panels PANEL CL - B - 1140x1972 PANEL CL - A - 1140x2044 1a) Line up the panels so that the top and bottom of each panel is PANEL CM - B - 1140x1972 flush with one another.
  • Page 9 Assembly Steps Pre-drill parts before fixing with screws STEP 1: PANELS Items: 1f) Create a frame by securing the timber using PANEL ED - 1520x343 1x 70mm screw per each connection. ST-PT35351380 ST-PT35701770.A 50mm SCREWS 70mm SCREWS ST-PT35351380 70mm SCREW ST-PT35701770.A ST-PT35701770.A ST-PT35351380...
  • Page 10 Assembly Steps Pre-drill parts before fixing with screws STEP 2: FLOOR Joining double bearer (1.1) 2a) Ensure the base is level. Space bearers at the Use 50mm screws. Items: specified distance as shown in the the diagram below (1.0). If the bearer layout consists of double bearers, use 50mm SCREW ST-PT35352240 50mm screws to secure them as shown in the image to...
  • Page 11 Assembly Steps Pre-drill parts before fixing with screws STEP 4: PANELS 4a) Position PANEL BE as shown below (1.0). Secure it to the Items: floor using 4x 70mm screws. PANEL BF - 1205x2117 PANEL BE - 1205x2117 4b) Use 5x 50mm screws to secure PANEL BF to PANEL CL. PANEL ED - 1520x2100 18x 50mm SCREW 4c) Repeat these steps for PANEL BF.
  • Page 12 Assembly Steps Pre-drill parts before fixing with screws STEP 5: WINDOW SILL Items: 5a) Place the window sill on the bottom of window on outside ST-PT2535815 (Window sill) surface of glass. 50mm SCREW 5b) Use 50mm screws to secure the sill to the frame. Ensure the screws are 50mm from both ends of the window sill and equally spaced.
  • Page 13 Assembly Steps Pre-drill parts before fixing with screws STEP 7: PURLINS 7a) Position the purlins as shown in the image below. Refer to image (1.0) for Items: spacing. ST-PT35702220.85.85 (Purlin) ST-PT3570171085.A (Purlin) 7b) Use 4x 70mm screws per each purlin, 2x for the front and 2x for the rear. 12x 70mm SCREW Secure them through the side and bottom.
  • Page 14 Assembly Steps Pre-drill parts before fixing with screws STEP 9: HINGES Items: 9a) Secure the trims for the door by using 3x 35mm screws all equally spaced per trim. PANEL - FD (LEAD) PANEL - FC (SECONDARY) 9b) Position the door in the frame ensuring there is a 5mm gap on each side of the HINGE door.
  • Page 15: Step 12: Drip Tray

    Assembly Steps Pre-drill parts before fixing with screws STEP 11: CORNER TRIM 11a) Position the timber trims in each corner of the shed, as shown in the diagram Items: below. Make sure that the end of trim is flush with the bottom wall shiplap. ST-PT15151860 (Rear) ST-PT15152000 (Side) 11b) Fix each corner trim into both panels.
  • Page 16 Assembly Steps Pre-drill parts before fixing with screws STEP 13: WIND BRACE 13a) Position the wind braces as shown in the diagram below. Make sure that they Items: are flush with edge of the roof board. ST-PT35352400 ST-PT35352370 13b) Fix each wind brace by using 35mm screws. Use 6 screws for each rear/side ST-PT35351600.45.45 wind brace.
  • Page 17 Assembly Steps Pre-drill parts before fixing with screws STEP 15: FASCIA BOARD AND DIAMOND FINIAL 15a) Position the fascia boards to the correct position as shown in the Items: diagram below. Fascia boards should be flush with the roof boards. Fix side ST-PT16701220 fascia boards to the wind brace by using 4x 35mm screws per each board.
  • Page 18 Assembly Steps CONGRATULATIONS - YOUR SHED IS NOW COMPLETE Page 18...