Selecting Configurations Using the SDCP
The SDCP's Liquid Crystal Display (LCD) consists of two 16-character lines which
display modem status, control functions, and configuration options as well as indicating
your location in the Top-Level menu tree.
To change the factory template for each modem using the SDCP, perform the following
steps:
"
Procedure
1. At the top level of the menu structure, select Modem A, B, or C by pressing F1, F2,
or F3.
2. Press the
key until Configure comes into view.
3. Press the function key below Configure to select the Configure branch.
The LCD now displays Ld EditArea frm.
4. Press the
key until Factory comes into view. Press the F1 key to display the
factory preset configurations.
Factory preset configurations are Async Dial, Sync Dial, Sync Leased, UNIX
Dial, and, if ETC is installed, Cellular(Mobile), and Cellular(PSTN). If Sync
Leased is selected, you must choose either Answer or Originate mode.
5. Press the
key until the appropriate factory preset appears on the LCD, and
press the corresponding function key to select your choice.
6. Choose Function appears and displays the Edit and Save functions.
7. Press the F3 key (Save) to save the new factory preset configuration to one of
three configuration areas, Active (Saved), Customer 1, or Customer 2.
(These three configuration areas are nonvolatile memory locations. Active (Saved)
contains the most recently saved changes to any configuration options. In the
event of power loss, the modem retrieves these configuration options. Customer 1
and Customer 2 are user-defined configuration areas.)
The LCD now displays Sav EditArea to.
8. Press the
key until the appropriate configuration area appears on the LCD,
then press the corresponding function key to select your choice. (Saving
configuration options to the Active (Saved) configuration area automatically saves
them to the Active (Operating) configuration area.) The LCD displays Command
Complete.
9. The modem is now configured with the selected factory template. Press the
key to return to the Top-Level menu.
7