Technical Specifications
and Water Treatment
Process Flow Diagram
Technical Specifications
Feed water quality: Municipal tap water
Voltage and frequency: 100~240V, 50/60Hz
Power input: 24V
Purified water flow: .35 gal/min
Feed water temperature: 45~110Fº
Feed-water TDS: ≤ 250ppm
Feed-water Chlorine level: ≤ 0.2ppm
Rejection: 90~99%
Feed-water pressure: 15~60psi
Electric shock resistance: type II
For warranty and support please register your new system at:
To complete the registration process you will need to enter
your systems serial number. It is usually located on a sticker on
Water Treatment Process
Flow Diagram
Technological process
Feed water
T33 filter
Goose faucet
Diagram
Power
Flush
Select
Reset
https://waterworldusa.com/registration-form/
the back of your system, or a labeled tag.
©2022 WaterworldUSA Inc. All Right Reserved.
PP filter
CTO filter
Ro
water
RO filter
Drain water
Sewer pipe
Water quality detector
Display
panel
Optional
10
Special pump
Inlet water solenoid water
Flush water solenoid water
Main
Pump
control
panel
Low pressure switch
High pressure switch