Microprocessor Memory Back-Up; Microprocessor Initialization - Kenwood TM-701A Instruction Manual

144/440mhz fm dual bander / 144/430mhz fm dual bander
Hide thumbs Also See for TM-701A:
Table of Contents

Advertisement

MR mode
. Select the desired VHF transmitter Memory channel.
. Press the BAND key and select the UHF receive Memory
channel.
. Press
the
F key
momentarily,
and
then
press
the
BAND/DUP
key. The D indicator will turn on in the
display.
. Press the PTT switch. The ON AIR indicator, and the VHF
transmitter frequency will appear in the display.
CALL channel mode
. Press the CALL key.
. Press the BAND key to alternate between the two CALL
channel display.
. Press the F key momentarily, then press the BAND/DUP
key. The D indicator will turn on in the display.
. Press the PTT switch. The ON AIR indicator, and the VHF
transmitting frequency will appear in the display.
4-4.
MEMORY
4-4-1.
Microprocessor Memory back-up
A lithium battery is contained in this transceiver to retain
memory. Turning OFF the POWER switch, disconnecting the
power cable or an intermittent power failure will not erase
the memories. The battery life is estimated at 5 years. When
the battery has been exhausted erroneous information might
appear in the display.
Lithium battery replacement should be performed by an
authorized KENWOOD
service facility, or your authorized
KENWOOD dealer. This equipment contains CMOS circuitry
and can be damaged by improper replacement procedures.
4-4-2.
Microprocessor Initialization
The initial state of the microprocessor, as delivered from the
factory is shown in the chart below.
VFO Frequency
Memory Channel
440,000 MHz
Frequency
144,000 MHz
(U.S.A. version)
Call Channel
430.000 MHz
Frequency
5 kHz
Frequency Step
12.5 kHz
25 kHz
(European version)
Memory Channel
2CH
1CH
Tone Frequency
88.5 Hz
88.5 Hz