Mantracourt DS485DIS User Manual page 17

Dsc rs485 display
Table of Contents

Advertisement

ST1F
63
ST2F
64
RESF
65
RST
100
DOZR
101
REMZ
102
Mantracourt Electronics Limited – DS485DIS User Manual
Set 1 Function
Advanced Mode only
Value
Mode
0
No Sets Displayed (Only inputs)
1
Sum of Child Inputs
2
Minimum of Child inputs
3
Maximum of Child inputs
4
Delta of Child Minimum and Maximum
Default 1
Range 0 to 4
Set 2 Function
Advanced Mode only
Value
Mode
0
Set2 not Displayed (Only Set1 if not disabled
itself)
1
Sum of Child Inputs
2
Minimum of Child inputs
3
Maximum of Child inputs
4
Delta of Child Minimum and Maximum
Default 1
Range 0 to 4
Result Function
Advanced Mode only
Value
Mode
0
Result not Displayed
1
Sum of Sets
2
Minimum of both Sets
3
Maximum of both Sets
4
Delta of Child Minimum and Maximum
5
Set Delta (Set1 – Set2)
Default 1
Range 0 to 5
Resets the module. Some parameter changes require a reset to
become active. These are B485, BUSB, FUNC, INTV and NOSV.
Performs a system zero.
Removes system zero.
Read/write
Read/write
Read/write
Command
Command
Command