Error Reporting

When errors occur in communications on one of the attached DSC or DLC modules the display will show Err followed
by a 2 digit error code.
The first digit indicates which DSC / DLC station number the error has occurred on.
The second digit indicates the error.
Only one error will be displayed at a time and on clearing the error the next (if one exists) will be displayed.
All errors are self resetting.
2
Digit
Description
nd
1
Communication error
2
Loadcell integrity error
3
Loadcell underrange
4
Loadcell Overrange
5
Cell limits exceeded
6
Sys limits exceeded
7
DSC/DLC Temperature limits exceeded
Errors 5 and 6 are dependent on parameter settings in the modules. The CMIN, CMAX, SMIN and SMAX
parameters will set the limits for these errors.
The display may also display OvEr or UndEr if the value cannot be displayed within the constraints of the configured
decimal point position.