Command List - Mantracourt DS485DIS User Manual

Dsc rs485 display
Table of Contents

Advertisement

Command List

Below is the list of Mantrabus parameters supported by the module using Mantrabus2 protocol over RS485 and via
the PC software Instrument Explorer.:
Note that listen only mode is not yet implemented
Parameter
Command
Name
Number
VERS
15
RESU
16
RESS
17
SET1
18
SET2
19
SRES
20
B485
40
BUSB
41
NOSV
42
Mantracourt Electronics Limited – DS485DIS User Manual
13
Description
Version
Result (before scale factor)
Result with Scale Factor applied
Set 1 Value
Set 2 Value
Set Result Value
Baudrate for RS485 port for connection to DSC and DLC bus.
This requires a RST command or a power cycle to activate.
Value
0
1
2
3
4
5
6
7
8
9
Default = 7 (115200)
Range = 0 to 9
Baudrate for virtual COM USB port. This requires a RST command or
a power cycle to activate.
Value
0
1
2
3
4
5
6
7
Default = 7 (115200)
Range = 0 to 7
Sets or returns the number of DSC or DLC devices connected.
Used for Legacy mode only. Requires a display power cycle to apply
new number of connected devices.
Default = 1
Baudrate
2400
4800
9600
19200
38400
57600
76800
115200
230400
460800
Baudrate
2400
4800
9600
19200
38400
57600
76800
115200
Data Type
Read only
Read only
Read only
Read only
Read only
Read only
Read/write
Read/write
Read/write

Advertisement

Table of Contents
loading

Table of Contents