6-11 Dynamic (Edge) Convergence
Use the following procedure to correct minor dynamic (edge) misconvergence. If, after using this
procedure, dynamic misconvergence is still greater than the 0.4 mm tolerance (around the periphery of the
display area), replace the CRT.
1.
Make sure the display is not affected by
Table 6-5. Magnetic Strips
'
external magnetic fields.
Description
Code Number
2.
Make sure the static convergence is properly
adjusted.
Magnet Sheet
Smmx80mm
937 319004CA
Magnet Sheet
10mmx 80mm
937 319004AA
3.
Strategically place small magnetic strips
on the back of the CRT to correct the
misconvergence. Be careful not to remove the
Warning
Do not remove the factory
paper protecting the adhesive on the magnetic
installed wedges. These wedges
strip until you are satisfied with their
were installed by the CRT manu-
placement and the dynamic convergence.
facturer and are properly placed
sigs
P
for this CRT. Removal may result
4.
When you are satisfied with the convergence
in damage to the CRT.
around the edge of the CRT, permanently glue
the magnets to the back of the CRT.