Set Mode Command Failed - Link Test Function Canceled; Timeout On Receive; Timeout On Transmit - IBM 3725 Manual

Communication controller stand-alone link tests
Table of Contents

Advertisement

(.
·(
(
(
(
f
(_
(
(:
·('
c
Set Mode Command Failed - Link Test Function Canceled
Timeout on Receive
Timeout on Transmit
Cause: The scanner did not respond to a Set Mode command.
Action:
1. Press Power ON to reset the 3725.
2. Re-IPL the Link Test program.
3. Restart the test.
If
the error persists, contact the service representative.
This message only applies to the requester.
Cause: A timeout occurred at the requester because no answer was received from
the responder within the timeout period.
Action:
1. Check that the responder is correctly IPLed.
2. Check the modems, cables, and the line.
3.
If
the error persists, contact the service representative.
Cause: The scanner did not reply to a command sent from the Link Test program
within the timeout period.
Action:
1. Re-IPL the Link Test program.
2. Restart the test.
3.
If
the error persists, contact the service representative.
Chapter 3. Link Test Messages
3-9