Insert the drain hose into the
9.
holder.
Cleaning the drain pump
Requirement: The drain pump is
empty. → Page 40
Since water may remain in the
1.
drain pump, unscrew the pump
cap carefully.
The filter insert in the pump
housing may become stuck due
to coarse particles of dirt.
Loosen the dirt and remove the
filter insert.
The pump cap is comprised of two
parts which can be taken apart for
cleaning.
Cleaning and servicing en
Clean the interior, the thread on
2.
the pump cap and the pump hous-
ing.
Ensure that both impellers can
3.
turn.
Insert the pump cap.
4.
Ensure that the parts of the
pump cap are correctly as-
sembled.
41