DRAIN PUMP
The pump should be inspected regularly
and particularly if:
• the appliance does not empty and/or
spin;
• the appliance makes an unusual noise
during draining due to objects such as
safety pins, coins etc. blocking the
pump;
• a problem with water draining is detected
(see chapter "Troubleshooting" for more
details).
A
B
Warning! Before unscrewing the pump
cover, switch the appliance off and
remove the mains plug from the
socket.
Proceed as follows:
1. Unplug the appliance.
2. If it is necessary, wait until the water
has cooled down.
3. Place a container close to the pump to
collect any spillage.
4. Release the emergency emptying hose
(B), place it in the container and re-
move its cap cover.
5. When no more water comes out, un-
screw the pump cover (A) by turning it
anti-clockwise and remove the filter.
Use pliers, if necessary.
Always keep a rag nearby to dry up
any water spillages when removing the
cover. Clean the filter under a tap, to
remove any traces of fluff.
6. Remove foreign bodies and fluff from
the filter seat and from the pump im-
peller.