Edge Preset Trigger Mode
9.3
In this trigger mode with positive polarity, the expose starts at rising edge of trigger signal. The exposure duration
time is based on preset exposure setting stored by camera setting communication.
In this trigger mode with negative polarity, the expose starts at falling edge of trigger signal. The exposure duration
time is based on preset exposure setting stored by camera setting communication.
Timing
Trigger signal
(Positive polarity)
Expose
Image out
Note: The exposure time is "Exposure Time" on GenICam setting.
STC-MBS122BPOE / STC-MCS122BPOE
Product Specifications and User's Guide
No.19S207-00
33/73