  • Page 1 Cole-Parmer ® HM-200 & SHM-200 Series Heating Mantles Instruction Manual M6873-CPB Version 13.1...
  • Page 3: Table Of Contents

    Please take your time to read this Instruction Manual in order to understand the safe and correct use of your new Cole-Parmer product. It is recommended the Responsible Body for use of this equipment reads this Instruction Manual and ensures the user(s) are suitably trained in its operation. Contents Section 1.
  • Page 4: Introduction

    1. INTRODUCTION 1.1. The Cole-Parmer series of heating mantles has been specifically designed to provide a comprehensive answer to heating fluids in round bottomed glassware in the modern laboratory. It combines the traditional Cole-Parmer heating element with many new features thus providing the user with several options to meet different applications. 1.2.
  • Page 5: Symbols And Using This Instructions Manual

    2. SYMBOLS AND USING THIS INSTRUCTION BOOK 2.1. Throughout this Instruction book the following symbols are shown to identify conditions which pose a hazard to the user, or to identify actions that should be observed. These symbols are also shown on the product, or its packaging. When a symbol is shown next to a paragraph or statement it is recommended the user takes particular note of that instruction in order to prevent damage to the equipment or to prevent injury to one’s self or other people.
  • Page 6: Safety Information

    3. SAFETY INFORMATION 3.1. This product has been designed for safe operation when used as detailed in accordance with the manufacturer’s instructions. NOTE: Failure to use this equipment in accordance with the manufactures operating instructions may compromise your basic safety protection afforded by the equipment and may invalidate the warranty / guarantee.
  • Page 7 Do not position the product so that it is difficult to disconnect from the mains supply. Do not touch the heating element or any glass vessel whilst in use. Do not lean or stretch over equipment, glassware and fixings when in use. Do not immerse unit in water or fluids.
  • Page 8: Unpack And Contents

    4. UNPACKING AND CONTENTS 4.1. Product Identification The model number allocated to each type of mantle is descriptive. The method of coding is detailed below. STIRRING AND NON-STIRRING MODELS Example SHM-200 - 50 - 115 Flask volume (ml) Supply Voltage Stirring Note: Non-Stirring models are prefixed “HM-200”.
  • Page 9 Please check the contents of your carton against the relevant product diagram. Applicable to all HM-200 and SHM-200 product range. Illustration only Item Description Instruction Book Mains cord and Moulded Plug and Lead set (May vary As Req from illustration). Heating Mantle –...
  • Page 10: Installation

    5. INSTALLATION 5.1. Electrical safety and installation 5.1.1. This equipment is designed to be used safely under the following conditions:- · Indoor use. · Altitude up to 2000 meters. · Temperatures between 5°C and 40°C. · Maximum relative humidity 80% for temperatures up to 31°C decreasing linearly to 50% relative humidity at 40°C.
  • Page 11: Environmental Protection

    USA Notification Warning ! Any modification or changes made to this device, unless explicitly approved by Cole- Parmer, will invalidate the authorisation of this device. Operation of an unauthorised device is prohibited under Section 302 of the Communications Act of 1934 as amended, and Subpart 1 of Part 2 of Chapter47 of the code of Federal Regulations.
  • Page 12: Product Operation

    7. PRODUCT OPERATION 7.1. HM-200, SHM-200, HM-200-V and HM-200-SP Mantle with controller Description Item Mains power indicator Heating element on Energy regulator control knob Heating element Warning labels Circuit selection switch (for mantles with two heating circuits) Data plate Mains input IEC socket (Contains protective fuses).
  • Page 13 7.2. SHM-200 Mantle (With Controller ans stir facility) Item Description. Mains power on indicator Heating element on Energy regulator control knob Heating element Warning labels (Hot surface and refer to the instruction manual) Stir speed adjustment Stir selection rotary switch Stir facility ‘on’...
  • Page 14: Technical Specification

    8. TECHNICAL SPECIFICATIONS 8.1. General specification 20mm x 5mm Glass Quickblow. (2 per Fuse Type unit) See below for rating Thermal insulated element wire stitched Heating element Construction into a cartridge construction Maximum Element Temperature C. Nominal Max HM / SHM-200 case Construction Polypropylene Thermal Insulation Ceramic Fibre...
  • Page 15 8.3. Dimensions and Weight (Unpacked) HM-200-50 Weight 0.78kg HM-200-100 Weight 0.78kg HM-200-250 Weight 0.78kg HM-200-500 Weight 1.25kg...
  • Page 16 HM-200-1000 Weight 1.25kg HM-200-2000 Weight 2.58kg HM-200-3000 Weight 2.58kg HM-200-5000 Weight 2.58kg...
  • Page 17 HM-200-V-50 Weight 0.78kg HM-200-V-250 Weight 0.78kg HM-200-V-1000 Glass size 500 - 1000ml HM-200-SP-1000 Glass size 50 - 1000ml Weight 2.76kg HM-200-V-5000 HM-200-SP-5000 Weight 5.69kg...
  • Page 18 SHM-200-50 Weight 1.73kg SHM-200-250 Weight 1.73kg SHM-200-500 Weight 2.75kg SHM-200-1000 Weight 2.75kg SHM-200-2000 Weight 5.68kg...
  • Page 19: Maintenance

    MAINTENANCE 9.1. General Information Unplug the unit from the mains voltage supply and allow it to cool before undertaking any maintenance tasks. Maintenance should only be carried out under the direction of the Responsible Body, by a competent electrician. Failure to do so may result in damage to the product and in extreme cases be a danger to the end user.
  • Page 20 9.3. Heater Cartridge Replacement. (SIZE 1, 2, 3) Cole-Parmer mantles contain Rockwool mineral insulation. When handling a suitable face mask which bears the CE mark should be used. A face mask to BS/EN 149 is adequate. When handling, wear gloves. Should skin irritation be experienced it can be lessened by rinsing hands under cold running water before washing.
  • Page 21 9.4. Spillage and Decontamination Spillage: In the event of spillage or glassware fracture, do not touch the mantle. Disconnect the product from the mains electrical supply. Allow the product to cool. Wearing suitable hand protection (giving due consideration to substances that were being heated) carefully remove any pieces of broken glassware.
  • Page 22: Replaceable Parts And Accessories

    10. REPLACEABLE PARTS AND ACCESSORIES 10.1. Replacement Heater Cartridges. All Cole-Parmer Mantle Replacement Heater Cartridges are specified by the letters RE and Flask size XXX0. For 115V products add suffix X1 to the replacement heater cartridge part number Replacement heater Mantle model type Cartridge HM-200-50...
  • Page 23 REPLACEABLE PARTS Order Number Description. Quantity AZ9021 Spares Pack Simmerstat Controller AZ9034 Fuse: F10A AZ9035 Fuse: F8A AZ9036 Fuse: F6.3A AZ9038 Fuse: F0.5A AZ9040 Fuse:F2.5A AZ9041 Fuse: F3.15A AZ9130 Fuse; F3A CRM5607 Neon: Clear (230V) CRM5608 Neon: Amber (230V) CRM5619 Neon: Clear (115V) CRM5620 Neon: Amber (115V)
  • Page 24: Customer Support

    11. CUSTOMER SUPPORT For help and support in using this product, please contact Customer Services at the following address. Antylia Scientific Beacon Road, Stone, Staffordshire, ST15 0SA, United Kingdom Tel: +44 (0)1785 812121 General enquiries: cpinfo@antylia.com Order enquiries: cpsales@antylia.com Technical support: cptechsupport@coleparmer.com www.coleparmer.com...
  • Page 25: Declaration Of Conformity Information

    12. DECLARATION OF CONFORMITY INFORMATION This product meets the sure other equipment used in its vicinity applicable CE Directives will meet these standards and so we and UKCA Legislation cannot guarantee that interference radio frequency will not occur in practise. Where there is a possibility that injury, damage interference and may be expected not to interfere or loss might occur if equipment...
  • Page 26: Notes

    13. Notes...
  • Page 27: Ordering Information

    Ordering Information Order No. Series Model Legacy SKU 36002-02 HM-200 HM-200-50 EM0050/CE 36002-00 HM-200 HM-200-50-115 EM0050/CEX1 36002-06 HM-200 HM-200-100 EM0100/CE 36002-04 HM-200 HM-200-100-115 EM0100/CEX1 36002-10 HM-200 HM-200-250 EM0250/CE 36002-08 HM-200 HM-200-250-115 EM0250/CEX1 36002-14 HM-200 HM-200-500 EM0500/CE 36002-12 HM-200 HM-200-500-115 EM0500/CEX1 36002-18 HM-200 HM-200-1000...
  • Page 29 Warranty Registration India T: +44 (0) 1480 272279 T: +9122 61394444 E: uk.sales@antylia.com E: info@coleparmer.in W: coleparmer.co.uk W: coleparmer.in Germany China T: +49 (0) 9377 92030 T: +1 847 549 7600 E: de.sales@antylia.com E: sales@antylia.com W: coleparmer.de W: coleparmer.com France T: +33 (0) 1486 37800 T: +1 847 549 7600 E: fr.sales@antylia.com...