Skil IF5940E-00 - Cordless Dual Function Inflator Manual

Skil IF5940E-00 - Cordless Dual Function Inflator Manual

Advertisement

Skil IF5940E-00 - Cordless Dual Function Inflator Manual

INTRODUCTION

  • This tool is intended for inflating tires, balls and other small volume items which fit the air chuck directly, or by using the supplied adapters
  • This tool is intended for inflating large volume items such as air beds, pools, boats, etc.
  • This tool is not intended for professional use
  • Read this instruction manual carefully before use and save it for future reference

OVERVIEW

Overview

SPECIFICATIONS

Rated voltage 20V max d.c. or 12V d.c. Vehicle Power
Maximum Air Pressure 11 BAR
Weight 2.3kg (2.5Ah battery attached)
2.5kg (5.0Ah battery attached)
Air speed 800L/min

USE

  • Charging battery
    information read the safety warnings and instructions provided with the charger
  • Removing/installing the battery
  • Battery protection

    The tool is suddenly being switched off or prevented from being switched on, when
    • the load is too high → remove load and restart
    • the battery temperature is not within the allowable operating temperature range of -20 to +50°C → 2 levels of the battery level indicator start flashing when pressing button c; wait until battery has returned within the allowable operating temperature range.
    • the battery is nearly empty (to protect against deep discharge) → a low battery level or flashing low battery level b is shown by the battery level indicator when pressing button; charge battery
      information do not continue to press the on/off switch after the tool is switched off automatically;
      battery may be damaged
  • Car socket connection
    Car socket connection
    • as alternative to a battery pack, the car socket can be used as power supply.
    • remove the car socket adapter from the storage compartment.
    • connect adapter to the car socket
  • On/off
    • press button
    • LCD display will show pressure information
    • by pressing the function button you can switch between high pressure (default) and high volume function
    • press LED button to turn the work light on/off
    • press button again to turn off
      information after approx. 5 minutes of inactivity the tool will automatically turn off

HIGH PRESSURE FUNCTION

  • Connecting the air hose
    Connecting the air hose
    • unlock the air chuck clamp
    • place the air chuck on valve stem
      information for Presta and Dunlop valves screw the adapter on the valve stem before placing the air chuck.
    • push the air chuck down so that the threaded section of the valve stem is inside the air chuck
    • lock the air chuck clamp
  • Removing/installing adapters
    Removing/installing adapters
    • unlock the air chuck clamp
    • push the adapter into the air chuck until it stops
    • lock the air chuck clamp
  • Set target pressure
    Set target pressure
    information make sure that the high pressure function is selected a
    • target pressure can be increased and decreased with + and – buttons to the desired value (between 0.2 and 11.0 bar)
    • to change the pressure unit press + and – buttons together
      information to avoid over inflation, read the instruction provided with the items to be inflated and never exceed recommended pressures
  • Inflating
    • to start inflating, press start/pause button
    • the actual pressure is shown
      information when the actual pressure is higher than the target pressure, the tool will not start inflating
    • to pause or stop inflating, press start/pause button again
    • the tool stops when the target pressure is reached
    • the tool stops when the target pressure is reached
      information the actual pressure may drop after the tool has stopped; you may restart inflating until the target pressure is reached
      information the tool may stop without reaching the target pressure when a low target pressure is set (< 2 bar); you may restart inflating until the target pressure is reached
      information allow the tool to cool down for 5 minutes after each 15 minutes of continuous use

HIGH VOLUME FUNCTION

  • Inflating
    • connect the high volume air hose to the air outletInflating
    • connect the other end of the hose to the item to be inflated directly or with the tapered adapter
      information make sure that the high volume function is selected b
    • to start inflating, press button
    • to pause or stop inflating, press button again
      information the tool does not stop automatically when high volume function is chosen
      information allow the tool to cool down for 5 minutes after each 15 minutes of continuous use
  • Deflating
    • for deflating, follow the instruction above, but connect the high volume air hose to the air intake
      Deflating

MAINTENANCE

  • This tool is not intended for professional use
  • Always keep tool clean (especially ventilation slots)
    information remove battery from tool before cleaning

SAFETY

  • Never allow children, persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge or people unfamiliar with these instructions to use the tool.
  • Supervise children(this will ensure that children do not play with the tool)
  • Cleaning and user maintenance of the tool shall not be made by children without supervision
  • Do not operate power tools in explosive atmospheres, such as in the presence of flammable liquids, gases or dust. Power tools create sparks which may ignite the dust or fumes.
  • Do not expose power tools to rain or wet conditions. Water entering a power tool will increase the risk of electric shock.
  • Store the tool indoors in a dry and locked-up place, out of reach of children
  • Do not use tool when damaged; take it to one of the officially registered SKIL Service Stations for a safety check
  • Have your power tool serviced by a qualified repair person using only identical replacement parts. This will ensure that the safety of the power tool is maintained.
  • Provide for good ventilation at the working place
  • Make sure that the hose is free of obstructions or snags. Entangled or snarled hoses may become damaged
  • Never leave an inflator unattended with the air hose attached
  • Do not continue to use an inflator or hose that leaks air or does not function properly
  • Do not attempt to pull or carry the inflator by the hoses Only use the following batteries and chargers with this tool
    • SKIL battery: BY5197E-03 BY5196E-03
    • SKIL charger: SC5358E-01 QC5360E-01 QC5359E-00
  • Do not use battery when damaged; it should be replaced immediately
  • Do not disassemble the battery
  • Do not expose tool/battery to rain
  • Permitted ambient temperature (tool/charger/battery):
    • when charging 4...40°C
    • during operation –20...+50°C
    • during storage –20...+50°C

EXPLANATION OF SYMBOLS ON TOOL/BATTERY


Read the instruction manual before use


Insulation class III


Do not dispose of electric tools and batteries together with household waste material

For Customer Service
1300-017-545
OR
www.skil.com.au

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Skil IF5940E-00 - Cordless Dual Function Inflator Manual

Advertisement

Need help?

Need help?

Do you have a question about the IF5940E-00 and is the answer not in the manual?

Questions and answers

Table of Contents