GFCI MAINTENANCE:
Although the GFCI function works on its own, it is nec-
essary to test for proper function of your GFCI periodi-
cally.
To do this:
1.
Plug your equipment to an appropriate wall plug
2.
Press the "TEST" button on the GFCI panel
3.
Turn on the switches for "PUMP" and "MOTOR"
3
(located on the switch panel on the handle).
If your motors turn on, then the GFCI is NOT working
properly- do not use the equipment until this function
has been repaired. Take the machine to an authorized
repair location.
If neither motor powers on after pressing the "TEST"
button then the GFCI is working properly.
Press the "RESET" button on the GFCI and the CR2 JR
will be fully functional again.
WARNING: Do not remove the grounding pin
from your power cord. Doing so will prevent the
GFCI from performing properly and can allow
dangerous operating conditions to go undetect-
ed. Replace power cords without grounding pins
immediately.
PROPRIETARY AND CONFIDENTIAL
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
EDIC. ANY REPRODUCTION IN PART OR
AS A WHOLE WITHOUT THE WRITTEN
PERMISSION OF EDIC IS PROHIBITED.
3

GROUNDING INSTRUCTIONS:

This piece of equipment must be grounded. Should an
electrical malfunction occur, grounding provides a path
of least resistance for electrical current- reducing the risk
of electric shock. This piece of equipment is furnished
with a cord that has a grounding conductor and ground-
2
RESET
BUTTON
TEST
BUTTON
UNLESS OTHERWISE SPECIFIED:
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL
ANGULAR: MACH
TWO PLACE DECIMAL
THREE PLACE DECIMAL
INTERPRET GEOMETRIC
TOLERANCING PER:
MATERIAL
FINISH
NEXT ASSY
USED ON
APPLICATION
DO NOT SCALE DRAWING
2
ing plug. The grounded plug must only be plugged
into an appropriate outlet that is properly installed and
grounded in accordance with all local codes and ordi-
nances.
WARNING:
Connecting the equipment to an improperly grounded
outlet can result in an increased risk of electric shock. A
qualified electrician should be consulted if you are unsure
that the outlet is properly grounded. Do not modify the
plug provided with the equipment. If it will not fit the
outlet, have a proper outlet installed by a qualified electri-
cian.
This appliance is designed for use on a 120-volt circuit.
The grounding plug provided looks like the plug illustrat-
ed in Figure 1. Replace the power cord if the grounding
pin is damaged or broken.
Extension cords connected to this machine should be
12 gauge, three-wire cords with three-prong plugs and
outlets. DO NOT use extension cords more than 25 feet
(7.6 m) long.
Figure 1
NAME
DATE
DRAWN
TITLE:
CHECKED
DEAD FRONT
BEND
ENG APPR.
MFG APPR.
Q.A.
COMMENTS:
SIZE
DWG. NO.
B
SCALE: 1:1 WEIGHT:
5
1
B
A
ENGINEERING DIVISION
1753 BLAKE AVENUE
LOS ANGELES, CA 90031
GFCI
REV
G13715
00
SHEET 1 OF 1
1

Advertisement

Table of Contents
loading

This manual is also suitable for:

2000rc

Table of Contents